Download 7154/7156 Variable Speed Drives
Electrical ballast wikipedia , lookup
Electric power system wikipedia , lookup
Stray voltage wikipedia , lookup
History of electric power transmission wikipedia , lookup
Distribution management system wikipedia , lookup
Power engineering wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Buck converter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Dynamometer wikipedia , lookup
Power inverter wikipedia , lookup
Three-phase electric power wikipedia , lookup
Utility frequency wikipedia , lookup
Electrification wikipedia , lookup
Brushless DC electric motor wikipedia , lookup
Power electronics wikipedia , lookup
Mains electricity wikipedia , lookup
Electric machine wikipedia , lookup
Electric motor wikipedia , lookup
Alternating current wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Voltage optimisation wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Stepper motor wikipedia , lookup
7154/7156 Variable Speed Drives Paul Weingartner 569-1776 Overview Variable Frequency drives (VFD) Application of VFDs Power quality issues Human Machine Interface (HMI) Standards organizations NEMA IEEE IEC NEMA Enclosures Motor characteristic curves History of adjustable speed systems Variable pitch pulley Motor-Generator (MG) set Eddy current clutch Solid state drives Problems Expensive Electrical (utility) issues Motor wear/tear Solid State drives DC drives AC soft start AC Variable frequency drives AC vector drives DC drives High torque Large speed ratios Regenerative braking DC motors – high maintenance Basics Speed Torque Horsepower Efficiency Power factor Real power Apparent power Leading power factor Inductive reactance Capacitive reactance Electric utilities Commerical customers are defined as users above 15KVA Electric charge Demand charge Power factor penalties Braking None – let load coast to stop Dynamic breaking – resistive load, uses generator effect Plugging – reverse polarity across motor DC injection – DC voltage is applied across two phases of an AC induction motor. Current must be limited and timing is critical for proper use Regenerative Mechanical brake Goals Ability to vary speed Limit power factor issues Sensitive to electric demand issues Often need “soft start” Cost savings Ways to start a motor Full voltage – Across the line starting Reduced voltage starting Soft start – limit current and rate of startup VFD – great latitude over motor control Relative cost difference for 1 HP motor Full voltage - $120 Reduced V - $200 Soft state - $250 VFD - $400 Motors 3 phase squirrel cage induction motor Principle of operation Synchronous speed Slip Starting characteristics NEMA classifications Motor Insulation class Motor VFD issues Volts/Hertz ratio Constant volts range VFD principle of operation 3 phase rectifier DC bus 3 phase inverter VFDs – 1st Generation VVI – Variable Voltage Inverters 6 step drive Uses SCRs on rectifier front end Variable voltage DC bus Problems with VVI drives Motor signal – not very sinusoidal, causes problems Sensitive to source voltage flucuations – 5-10% change will fault the drive At low speed the drive will “cog” creating stresses on shafts, etc – freq should be above 15 Hz Drive will reflect harmonics back to the line Short power loss is bad CSI – Current Source Inverter Similar to VVI, but adds a line reactor on the DC bus Supports regenerative braking without needing extra hardware Creates harmonics PWM Operating frequency – carrier frequency Increasing the carrier frequency decreases the efficiency of the drive electronics Duty cycle t-on t-off Transistor example Linear operation vs. PWM Power dissipation PWM drives Uses diodes for the rectifer, creating a Constant voltage DC bus Constant power factor – due to diode front end Full operating torque at near zero speed No cogging Can ride thru a power loss from 2 Hz to 20 seconds VFD drives Scalar Vector 3 phase motor NEMA Motor Curves 1336 picture 1336 – Description of L7E option 1336 Drive literature link http://www.ab.com/drives/1336PlusII/literat ure/index.html PWM inverter Motor selection criteria Synchronous speed AC motors have a sync design speed that is a function of the number of poles and the line frequency At sync speed ZERO torque is generated Therefore, motors cannot run at sync speed Motor slip Since motors cannot run at sync speed, the will run at slightly less than this speed. “Slip” is the term used to describe the difference between the sync speed and the maximum rated speed at full load Motor slip calc This formula includes a characteristic called slip. In a motor, slip is the difference between the rotating magnetic field in the stator and the actual rotor speed. When a magnetic field passes through the rotor's conductors, the rotor takes on magnetic fields of its own. These induced rotor magnetic fields will try to catch up to the rotating fields of the stator. However, there is always a slight speed lag, or slip. For a NEMA-B motor, slip is 35% of its base speed, which is 1,800 rpm at full load. For example, Volts/Hertz Drive frequency The speed at which IGBTs are switched on and off is called the carrier frequency or switch frequency. The higher the switch frequency, the more resolution each PWM pulse contains. Typical switch frequencies are 3,000 to 4,000 times per second (3-4 kHz). As you can imagine, the higher the switch frequency, the smoother (higher resolution) the output waveform. However, there is a disadvantage: Higher switch frequencies cause decreased drive efficiency. The faster the switching rate, the faster the IGBTs turn on and off. This causes increased heat in the IGBTs. High motor voltages http://www.mtecorp.com/solving.html High peak voltages Fast rise times Standard Motor Capabilities established by the National Electrical Manufacturers Association (NEMA)and expressed in the MG- I standard (part 30), indicate that standard NEMA type B motors can withstand 1000 volts peak at a minimum rise time of 2 u-sec (microseconds). Therefore to protect standard NEMA Design B motors, one should limit peak voltage to 1KV and reduce the voltage rise to less than 500 volts per micro-second. Constant torque loads Conveyor systems Constant horsepower loads grinders, winders, and lathes Variable torque loads fans and pumps Motor ventilation TENV TEFC ODP High Altitude considerations Motor soft start Limit inrush current Linear ramp S-curve Skip freq Flux vector drives http://www.mikrokontrol.co.yu/sysdrive/Wh atInv.htm#FV