Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
SEC 11 12 00 PARKING CONTROL EQUIPMENT Page 1 of 6 PARKING CONTROL EQUIPMENT SECTION 11 12 00 PARKING/BARRIER GATE OPERATOR DoorKing Model 1601 Display hidden notes. (Don’t know how? Click Here) PART 1 - GENERAL 1.1 WORK INCLUDED A. Furnish and install a complete microprocessor based parking gate operator system, with a solid-state board to control all functions of the parking gate operator, as described herein and shown on the plans. Include all necessary boards, power supplies, loop detectors, barrier arm(s), connectors, and accessories for a complete operational system. 1.2 CONTRACT DOCUMENTS A. All equipment and work specified in this section shall comply, with all the General Conditions of the specifications, contract documents, and drawings as indicated. 1.3 RELATED WORK A. Parking control contractor shall coordinate all work with other contractors and trades where necessary. B. All necessary conduit, raceways and pull boxes shall be installed by the electrical contractor. C. Installation of the parking gate operator system shall be coordinated with the installation of other parking control related systems. 1.4 QUALITY ASSURANCE A. Installation shall comply with all applicable codes. B. All equipment shall be new, in current production, and the standard products of a manufacturer of vehicular access and parking control equipment. C. Manufacturer shall guarantee availability of parts, for a minimum of seven (7) years from date of shipment. D. If required, manufacturer shall be able to demonstrate features, functions, operating characteristics to the Owner. E. System shall be installed by a factory authorized contractor, with technicians specifically trained in this system. F. On-site maintenance and repair service shall be available locally and within four (4) hours of notification for emergency condition. 1.5 REFERENCE STANDARDS A. Vehicular Parking Gate Operator shall be in compliance with Underwriters Laboratories Inc. (UL) Standard for Safety - Door, Drapery, Gate, Louver and Window Operators and Systems, UL 325 Fourth Edition; and Underwriters Laboratories Inc. (UL) Standard for Safety - Tests for Safety-Related Controls Employing Solid-State Devices, UL 991 Second Edition. PARKING GATE OPERATORS 1601 REV 6/13 SEC 11 12 00 PARKING CONTROL EQUIPMENT Page 2 of 6 B. Vehicular Parking Gate Operator shall be tested for compliance to UL 325 and UL 991 and shall be LISTED by a Nationally Recognized Testing Laboratory (NRTL). 1.6 SUBMITTALS A. Provisions: Comply with Section 01 33 00 SUBMITTALS. B. Shall include an equipment list, data sheet(s), system description, block diagrams on equipment to be finished and electrical wiring diagrams for installation. C. Shall include all data necessary to evaluate design, quality, and configuration of proposed equipment and system(s). 1.7 WARRANTY A. Products shall include a factory warranty that equipment is free from defects in design, material, manufacturing and operation. Factory warranty period shall be for five (5) years; 60-months from date of shipment, for parts and workmanship. B. Manufacturer shall not be responsible for improper use, handling, or installation of the product. C. Installing contractor shall guarantee the equipment, wire and installation for 12-months from date of acceptance. PART 2 - PRODUCTS 2.1 ACCEPTABLE MANUFACTURERS A. The system as described herein is based on the DoorKing 1600 series vehicular parking gate operator system manufactured by DoorKing, Inc., Inglewood, California. The vehicular parking gate system specified meets requirements of the specifications and shall be considered as the acceptable Base Bid. B. Substitutions must meet requirements of Prior Approval, as outlined in the contract documents. Substitutions that meet prior approval requirements must be listed as alternates by addendum, and shall be shown separately on the bid forms. Consideration will be based on ability to comply with all aspects of the specifications, the desired functional operation, quality, reliability, design, size, and appearance of the equipment, and the support capabilities of the manufacturer. 2.2 SYSTEM DESCRIPTION A. Parking Gate Operator: 1. The parking gate operator shall use a microprocessor based solidstate control board that controls all functions of the parking gate operator. The system is designed so that mechanical relays or limit switches are not required. Operators shall be rated for continuous duty for use in commercial and industrial applications. 2. Gear reducer output shall use 360° rotation to avoid wear. 3. Power shall be transmitted to the gate arm drive shaft through harmonic acting crank and connecting arm. 4. Crank, connecting arm and main shaft shall be solid steel construction and plated to avoid rusting. 5. Mechanical action of the driven arm shall be such that mechanical stops or braking devices are not necessary. PARKING GATE OPERATORS 1601 REV 6/13 SEC 11 12 00 PARKING CONTROL EQUIPMENT Page 3 of 6 6. Operator housing shall use 12-gauge G90 galvanized steel to avoid rusting and shall be painted white. 7. Operator shall be designed for either left or right-hand mount. B. Control Circuit: 1. The parking gate operator shall use magnetic sensing to set the up and the down arm limits. 2. An adjustable timer shall be built into the control board to allow the barrier arm to automatically close. 3. Control board shall have connections for optional Gate Tracker board. Gate tracker shall record operator cycles (x100), input errors, loop detector errors, obstruction hits, and power up events. Record shall be time and date stamped. 4. Control board shall have two ports for plug in of optional loop detectors, (DoorKing, Models 9409 or 9410). 5. The control board shall have an up input memory buffer and a down memory counter for high traffic applications. 6. A dry set of relay contacts shall be available for external use, and shall be capable of working in conjunction with an up or down inductance loop. 7. The control board shall be capable of interfacing with card readers, RF transmitters, and coin and ticket machines. 8. Functions will be user programmable by DIP-switches located on the control board. 9. Control circuit shall include auto-manual toggle switch and power on-off switch. C. Environmental Control: 1. The parking gate operator shall be pre-wired to accept optional heater and fan kits. D. Gate Sequencing: 1. Control board shall include special inputs for sequencing the parking gate operator with slide or swing gate operators when installed in PAMS (Perimeter Access Management Solution) applications. 2. Sequencing logic shall be an integral part of the control board logic and shall not rely on external or add-on relays. E. Electronic Reverse: The parking gate operator shall be equipped with an inherent electronic current sensor. The electronic reverse shall automatically cause a descending arm to rise if it strikes an object during the down cycle. F. Secondary Entrapment Prevention 1. Non-contact sensors, or contact sensors, or combination thereof, shall be utilized to prevent persons from becoming entrapped in the gate system. 2. Warning signs shall be installed in accordance with manufacturer’s installation instructions and UL 325 guidelines. G. A complete operational system shall be provided. 2.3 EQUIPMENT A. Parking Gate Operators: 1. Model 1601 PARKING GATE OPERATORS 1601 REV 6/13 SEC 11 12 00 PARKING CONTROL EQUIPMENT Page 4 of 6 a. b. c. d. High-cycle single-lane applications. Maximum gate arm length is 14 feet. 1 / 2 horsepower continuous duty motor. Primary reduction and power transfer is provided by a single cog belt driving a 40:1 worm gear reducer running in a continuous oil bath. e. The operator will rotate the arm 90° in approximately 1.5 seconds. f. 38 inches high, 15 inches wide, 14.75 inches deep. g. Power i. 115 VAC ii. 208 VAC iii. 230 VAC iv. 460 VAC v. 575 VAC B. Barrier Arms: 1. Aluminum Arm P/N 1601-516 a. 3-inch round aluminum arm painted white with red/white MUTCD compliant retro-reflective warning tape. b. P/N 1601-242 Aluminum arm mounting kit (required to install aluminum arm on parking gate operator). 2. Wood Arm P/N 1601-348 a. 1 x 4 inch wood arm painted white with red/white MUTCD compliant retro-reflective warning tape. b. P/N 1601-240 Wood arm mounting kit (required to install wood arm on parking gate operator). 3. Plastic Arm P/N 1601-571 a. 2 x 2 inch white plastic arm with red/white MUTCD compliant retro-reflective warning tape. b. P/N 1601-241 Plastic arm mounting kit (required to install wood arm on parking gate operator). C. Optional Equipment: 1. Vehicle Loop Detectors a. P/N 9410-010 Single channel detector. b. P/N 9409-010 Two channel detector. 2. Non-contact sensors (photo-cells). a. P/N 8080-010 Infrared thru-beam, 165 foot sensing distance. b. P/N 8080-011 Photo-reflective beam, 30 foot sensing distance. c. P/N 8080-030 Polarized photo-reflective beam, 35 foot sensing distance. d. P/N 8080-031 Infrared thru-beam 65 foot sensing distance. 3. Contact sensors a. P/N 8080-016 Single-sided sensitivity with mounting channel. 4. Environmental Control a. P/N 1601-092 Heater kit. b. P/N 1601-093 Fan kit. 5. Low Headroom Arm Kit a. P/N 1601-083 Plastic Arm Low Headroom Kit. b. P/N 1601-084 Wood Arm Low Headroom Kit. c. P/N 1601-310 Aluminum Arm Low Headroom Kit. 6. Foam padding for aluminum arm P/N 1601-560 7. Traffic Control Signal (Red/Green) P/N 1603-208 8. Manual Crank Kit P/N 1601-270 9. Gate Tracker: The vehicular slide gate operator shall have output for connection to Gate Tracker control board. Gate Tracker shall PARKING GATE OPERATORS 1601 REV 6/13 SEC 11 12 00 PARKING CONTROL EQUIPMENT Page 5 of 6 maintain a detailed electronic record of cycles, input errors, loop detector errors, obstruction hits, and each time power is applied to the operator, time and date stamped. 10.Convenience open (battery backup) drive system. D. A complete operational system shall be provided. PART 3 - EXECUTION 3.1 INSTALLATION A. It is preferred, but not required, that this product be installed by a qualified technician who is certified by the Institute of Door Dealer Education and Accreditation (IDEA) as a Certified Automatic Gate Operator Installer (CAGOI). B. Equipment shall be mounted directly to a concrete pad, firmly secured, plumb, and level. C. Wiring shall be uniform and in accordance with national electric codes and manufacturers instructions. D. All splices shall be in easily accessible junction boxes or on terminal boards. E. All cable runs in all junction boxes shall be tagged and identified. F. Coordinate all work with other effected trades and contractors. 3.2 SYSTEM INITIALIZING AND PROGRAMMING A. System shall be turned on and adjustment made to meet requirements of specifications and on-site conditions. B. System shall function as specified. 3.3 SYSTEM TEST PROCEDURES A. System shall be accessories are B. System shall be accordance with C. System shall be 3.4 completely tested to assure that all components and hooked-up and in working order. pre-tested by contractor and certified to function in plans and specifications. tested in presence of owner's representative. OWNER INSTRUCTIONS A. Installation contractor shall conduct up to (1) hour of instruction in use and operation of the system to designated owner representatives, within (30) days of acceptance. B. Installation contractor shall conduct up to (1) hour of technical training, in trouble shooting and service of the system, to designated owner representatives within (90) days of system acceptance. 3.5 MANUALS AND DRAWINGS A. Contractor shall provide owner with (2) copies of standard factory prepared operation, installation and maintenance manuals. Manuals shall include typical wiring diagrams. B. Contractor shall provide owner with (2) copies of any risers, layouts, and special wiring diagrams showing any changes to standard drawings, if required on project. 3.6 MAINTENANCE PARKING GATE OPERATORS 1601 REV 6/13 SEC 11 12 00 PARKING CONTROL EQUIPMENT Page 6 of 6 A. The manufacturer recommends periodic maintenance at three month intervals as described in the installation and maintenance manual. B. External reversing devices should be checked at least once a month. END OF SECTION PARKING GATE OPERATORS 1601 REV 6/13