* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download V rms
Standby power wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Ground (electricity) wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Current source wikipedia , lookup
Wireless power transfer wikipedia , lookup
Electrical ballast wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power over Ethernet wikipedia , lookup
Opto-isolator wikipedia , lookup
Power inverter wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Audio power wikipedia , lookup
Power factor wikipedia , lookup
Electrification wikipedia , lookup
Power MOSFET wikipedia , lookup
Electrical substation wikipedia , lookup
Electric power system wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Surge protector wikipedia , lookup
Stray voltage wikipedia , lookup
Buck converter wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power engineering wikipedia , lookup
Power electronics wikipedia , lookup
Power supply wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Alternating current wikipedia , lookup
ECE 4501 Power Systems Laboratory Manual Rev 1.0 3.0 THREE-PHASE AC CIRCUITS 3.1 THREE-PHASE VOLTAGE AND CURRENT 3.1.1 OBJECTIVE To study the relationship between voltage, current and power in three-phase circuits and examine wye and delta connections. 3.1.2 DISCUSSION In practice three-phase circuits in proper working order tend to be symmetrical, consisting of three identical branches, each with the same impedance, voltage and current. Each of the branches can be treated as a single-phase circuit, and thus the analysis of a three-phase circuit is not necessarily any more difficult than the corresponding single-phase network. Unbalanced three-phase networks usually represent a problematic condition, such as a fault, and can be much more difficult to analyze. Unbalanced conditions are beyond the scope of this laboratory exercise. Three-phase systems are normally configured in either a WYE or DELTA. The names result from the physical similarity of the wye connection to the letter Y and the delta connection to the Greek letter of the same name (a triangular symbol). Each of these configurations has unique electrical characteristics. 3.1.3 INSTRUMENTS AND COMPONENTS Power Supply Module Resistance Module AC Metering Module (2.5 A) AC Metering Module (250 V) 3.1.4 EMS 8821 EMS 8311 EMS 8425 EMS 8426 PROCEDURE CAUTION! – High voltages are present in this Experiment. DO NOT make any connections with the power supply ON. Get in the habit of turning OFF the power supply after every measurement. 1) Use the power supply and AC voltmeter module to connect the following circuit: - 1- ECE 4501 Power Systems Laboratory Manual Rev 1.0 V 4 to 5 = _______ V rms V 5 to 6 = _______ V rms V 6 to 4 = _______ V rms V L-L Avg. = ______ V rms 2) Turn on the power supply and adjust the voltage control knob until the line-to-neutral voltage, V4N is exactly 120 V rms, as read from the power supply’s voltmeter. 3) Measure and record each Line-to-Line voltage from the voltmeters. 4) Turn the voltage control knob to zero percent and turn OFF the power supply. 5) Calculate the numeric average of the three line-to-line voltages and enter the result above. 6) Reconnect the voltmeters to read the line-to-neutral voltages of the power supply as shown below: V 4 to N = _______ V rms V 5 to N = _______ V rms V 6 to N = _______ V rms V L-N Avg. = ______ V rms - 2- ECE 4501 Power Systems Laboratory Manual Rev 1.0 7) Turn on the power supply and adjust the voltage control knob until the line-to-neutral voltage, V4N is exactly 120 V rms, as read from the power supply’s voltmeter. 8) Measure and record each Line-to-Neutral voltage (also called Phase Voltage) from the voltmeters. 9) Turn the voltage control knob to zero percent and turn OFF the power supply. 10) Calculate the numeric average of the three line-to-neutral voltages and enter the result above. 11) Calculate the ratio of the average line-to-line voltage to the average line-to-neutral voltage and enter the result here: ________________________________________________________________ 12) Is this ratio approximately the square root of three? ______________ 13) Repeat the voltage measurement procedures for line-to-line and line-to-neutral voltages, steps 1 through 9 above, on the fixed 120/208 V power supply (terminals 1,2,3, and N) and enter the results below: Fixed Supply: Line-to-line Fixed Supply: Line-to-Neutral Line Voltages: Phase Voltages: V 1 to 2 = _______ V rms V 1 to N = _______ V rms V 2 to 3 = _______ V rms V 2 to N = _______ V rms V 3 to 1 = _______ V rms V 3 to N = _______ V rms 14) Are the readings for each phase similar to the readings of the other two phases for each of the measurements? ______________ 15) Is the voltage between any two terminals, for example, V 3 to 1, V 5 to N or perhaps even V 3 to 5, 16) a single-phase or a three-phase voltage? ____________ Using the modules listed under Instruments and Components, build the following WYE circuit. DO NOT CONNECT THE NEUTRAL POINT OF THE WYE LOAD WITH THE NEUTRAL OF THE POWER SUPPLY. - 3- ECE 4501 Power Systems Laboratory Manual Rev 1.0 Phase Voltages and Phase Currents: V1 = _______ V rms V2 = _______ V rms V3 = _______ V rms I1 = _______ A rms I2 = _______ A rms I3 = _______ A rms 17) Set each resistance section to 400 Ohms. 18) Turn on the power supply and adjust the voltage control until the meter on the power supply reads, V45 = 208 V rms (line-to-line). 19) Measure and record the voltages and currents on the instruments. Calculate the numeric average for both voltage and current for use in the table below. 20) Turn the voltage control knob to zero percent and turn OFF the power supply. 21) Are the voltages and currents reasonably balanced? ________________ 22) Calculate the average phase voltage and current and also the apparent power (S = VI) dissipated by each phase and also the power delivered by the source: (Note: For a pure resistance, the apparent power, S, is equal to the real power, P.) Average Value of Phase Voltage and Phase Current: Three Phase Power in a WYE: Vphase = ______ V Iphase = ______ A Ptot = P1 + P2 + P3 = _______ W S1 = V1I1 = _______ VA = P1 S3 = 3 VLineILine S2 = V2I2 = _______ VA = P2 = 3 (3 Vphase)Iphase = _______ VA S3 = V3I3 = _______ VA = P3 S3 = P3 = Ptot - 4- ECE 4501 23) Power Systems Laboratory Manual Rev 1.0 Connect the following DELTA circuit: Phase Voltages and Phase Currents: V1 = _______ V rms V2 = _______ V rms V3 = _______ V rms I1 = _______ A rms I2 = _______ A rms I3 = _______ A rms 24) Set each resistance section to 400 Ohms. 25) Turn on the power supply and adjust the voltage control until the meter on the power supply reads V45 = 120 V rms (line-to-line). 26) Measure and record the phase voltages and currents on the instruments. 27) Turn the voltage control knob to zero percent and turn OFF the power supply 28) Are the voltages and currents reasonably balanced? ________________ 29) Calculate the average phase voltage and current and also the apparent power ( S = VI) dissipated by the resistor in each phase: Average Value of Phase Voltage and Phase Current: Vphase = ______ V Iphase = ______ A S1 = V1I1 = _______ VA = P1 S2 = V2I2 = _______ VA = P2 S3 = V3I3 = _______ VA = P3 - 5- ECE 4501 Power Systems Laboratory Manual 30) Rev 1.0 Disconnect the three current meters and insert them in series with the power supply terminals. Rebuild the DELTA by placing connection leads as needed such that the circuit looks like the one shown below: Line Currents: I4 = _______ A I5 = _______ A I6 = _______ A Iline = _______ A 31) Turn on the power supply and adjust the voltage control until the meter on the power supply reads V45 = 120 V rms (line-to-line). 32) Measure and record the line currents on the ammeters and calculate the numeric average, Iline. 33) Turn the voltage control knob to zero percent and turn OFF the power supply 34) Calculate the ratio of the average line current, Iline, to the average phase current, Iphase. Also calculate the three-phase power delivered by the source: Ratio of Line Current to Phase Current in a Delta Circuit: Iline/Iphase = ________ Three Phase Power in a DELTA: Ptot = P1 + P2 + P3 = _______ W S3 = 3 Vphase Iphase = 3 VLine ILine Does this ratio equal the square root of three? ____________ = 3 Vphase (3Iphase) = 3 Vphase ILine = _______ VA S3 = P3 = Ptot (S = P in purely resistive circuit, only) - 6- ECE 4501 3.1.5 Power Systems Laboratory Manual Rev 1.0 CONCLUSIONS 1) In a WYE connected circuit, if the line-to-line voltage is 346 Volts, rms, what is the line-to-neutral voltage? ________________________________________________________________________ ________________________________________________________________________ 2) In a DELTA connected circuit, the current is 20 amperes in each phase. What is the line current? ________________________________________________________________________ ________________________________________________________________________ 3) In a WYE connected circuit the current is 10 Amperes per phase. What is the line current? ________________________________________________________________________ ________________________________________________________________________ 4) A WYE connected load has a resistance of 10 Ohms per phase. If the total three-phase power dissipated by the load is 3000 Watts, what is the line-to-line voltage of the source? ________________________________________________________________________ ________________________________________________________________________ 5) Three 11-Ohm resistors are connected in DELTA across a 3-phase, 440-Volt line. What is a) the line current and b) the total three-phase power? ________________________________________________________________________ ________________________________________________________________________ - 7- ECE 4501 Power Systems Laboratory Manual 3.2 THREE PHASE WATTS, VARS AND VOLTAMPERES 3.2.1 OBJECTIVE Rev 1.0 To determine the apparent, real and reactive power in three phase circuits and calculate power factor. 3.2.2 DISCUSSION Section 3.1 examined the nature of real power in three phase circuits. By measuring the voltage drop across a load resistor and measuring the current flowing through it, one was able to calculate the apparent power dissipated by the resistor (S=VI). Since the load was a pure resistance, the apparent power, S, was equal to the real power, P. Mathematically, one would say that P = VI cos . The power factor angle, , is the phase angle difference between the voltage phasor and the current phasor, as determined by the equation, = angle (V) – angle (I). In the case of a pure resistance, the voltage and current phasors are ‘in phase’ and thus is zero degrees. Therefore, P = VI cos (0) = VI = S. This section will demonstrate that reactive power, Q, either capacitive or inductive, can also be measured in the same manner. When the magnitude of the voltage drop across an inductor or capacitor is measured, along with the current flowing through it, one is able to say mathematically, Q = VI sin . In the case of a pure inductance, the voltage and current phasors are out of phase by 90 (The convention is to say that, for an inductor, the current lags the voltage by 90). Thus, Q = VI sin = VI sin (90) = VI = S. However, in the case of a pure capacitance, the current phasor leads the voltage phasor by 90 and thus they are out of phase by -90. Hence, Q = VI sin (-90) = -VI = -S. It is therefore extremely important to know if the reactive load is capacitive or inductive because it will change the sign of the reactive power. Knowing both real and reactive power in a circuit with a load consisting of both real and reactive elements, it is then possible to calculate the apparent power and power factor for balanced three phase circuits. 3.2.3 INSTRUMENTS AND COMPONENTS Power Supply Module (0 – 120/208 Vac) Resistance Module Inductance Module AC Metering Module (0.5 A, 3 phase) AC Metering Module (250 V, 3 phase) 3.2.4 EMS 8821 EMS 8311 EMS 8321 EMS 8425 EMS 8426 PROCEDURE CAUTION! – High voltages are present in this Experiment. DO NOT make any connections with the power supply ON. Get in the habit of turning OFF the power supply after every measurement. 1) Using the equipment listed above, connect the WYE circuit shown below. DO NOT CONNECT THE NEUTRAL POINT OF THE THREE LOAD INDUCTORS TO THE NEUTRAL OF THE POWER SUPPLY. - 8- ECE 4501 Power Systems Laboratory Manual Rev 1.0 Phase Voltages and Currents: V1 = _______ V rms V2 = _______ V rms V3 = _______ V rms I1 = _______ A rms I2 = _______ A rms I3 = _______ A rms Average Values: Vphase = _______ V rms Iphase = _______ A rms 2) Set each inductance section to a reactance of 300 Ohms. 3) Turn on the power supply and adjust the voltage control for 208 V rms (line to line). 4) Measure and record the voltages and currents associated with the three inductive loads. 5) Return the voltage control to zero percent and turn OFF the power supply. 6) Calculate the numeric average of the phase currents and phase voltages and enter the results in the space provided above. 7) Calculate the apparent power for each of the inductive loads using S = VI. Note that since the loads are almost purely inductive, the apparent power, S, will be equal to the reactive power, Q. (See 3.2.2 DISCUSSION) Also calculate the total three-phase reactive power by summing the three individual phases. (see table on next page) - 9- ECE 4501 Power Systems Laboratory Manual Rev 1.0 Apparent Power in Inductive Load: Three-phase Power: V1I1 = _______ VA = Q1 Q3 = Q1+ Q2+ Q3= _______ VAR V2I2 = _______ VA = Q2 S3 = 3 VlineIline V3I3 = _______ VA = Q3 = 3 VphaseIphase = ________ VA 8) Now calculate the three-phase apparent power, S3 = 3 VI and compare the result to the three phase sum calculated in 7) above. Do they compare favorably? ___________ 9) Using the Resistance Module, add 400 Ohms of resistors to each phase of the WYE load, in series with the inductors as shown below. DO NOT CONNECT THE NEUTRAL POINT OF THE LOAD TO THE NEUTRAL OF THE POWER SUPPLY. Inductor Voltages and Phase Currents: V1 = _______ V rms V2 = _______ V rms V3 = _______ V rms I1 = _______ A rms I2 = _______ A rms I3 = _______ A rms 10) With the resistance set at 400 Ohms per phase and the inductance set at 300 Ohms per phase, turn on the power supply and adjust the voltage control for 208 V rms (line to line). 11) Measure and record the voltages and currents associated with the three inductive portions of the load. 12) Return the voltage control to zero percent and turn OFF the power supply. 13) Now reconnect the voltmeters so that they read the voltage drops associated with the resistors in the circuit, as shown in the diagram below: - 10 - ECE 4501 Power Systems Laboratory Manual Rev 1.0 Resistor Voltages: V4 = _______ V rms V5 = _______ V rms V6 = _______ V rms 14) Turn on the power supply and adjust the voltage control for 208 V rms (line to line). 15) Measure and record the voltage drops across the resistors in the circuit. 16) Return the voltage control to zero percent and turn OFF the power supply. 17) By measuring the phase current and the voltage drop across any component in a WYE load it is possible to calculate the apparent power dissipated in that component using S = VI. In the case of the inductive element, the apparent power will be purely reactive, Q (in VARs). In the case of a resistive component, the apparent power will be purely real, P. Now, using the voltages and currents measured in the two circuits, calculate the real and reactive powers associated with the WYE load: Real Power in the Resistors: Reactive Power in the Inductors: P1 = I1 V4 = _______ Watts Q1 = I1 V1 = _______ VARs P2 = I2 V5 = _______ Watts Q2 = I2 V2 = _______ VARs P3 = I3 V6 = _______ Watts Q3 = I3 V3 = _______ VARs P3 = P1 + P2 + P3 = _______ W Q3 = Q1+ Q2+ Q3= _______ VAR 18) Now calculate the total three-phase apparent power using the power triangle and the Pythagorean Theorem : (see diagram on next page) - 11 - ECE 4501 Power Systems Laboratory Manual Rev 1.0 Apparent Power for Complex Load: S3 = { (P3)2 + (Q3)2 } S3 = ________ VA Which should be similar to: S3 = 3 VlineIline = _______ VA 19) Also calculate the total three-phase apparent power using S3 = 3 VlineIline : 20) Finally, calculate the power factor using the equation, pf = P/S: Power Factor, pf = _______ Watts / _______ VA = ________, leading or lagging (circle one) 3.2.5 CONCLUSIONS 1) A three-phase motor draws 10 amps of current from a 440-volt line at a power factor of 80 percent, lagging. Calculate the three-phase apparent power, S, and the three-phase real power, P: ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ 2) A transformer supplies 120 kVA to a three-phase load at a line voltage of 2400 V rms. Find the line current: ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ - 12 -