
Download G3000 Datasheet
... G3000 Series Frequency Relay Description The G3000 Frequency Relay is intended for frequency monitoring on generators, busbars or other distribution systems. The relay contains the functions “under frequency” and “over frequency”, time delayed, and two individual output relays—one relay for each fun ...
... G3000 Series Frequency Relay Description The G3000 Frequency Relay is intended for frequency monitoring on generators, busbars or other distribution systems. The relay contains the functions “under frequency” and “over frequency”, time delayed, and two individual output relays—one relay for each fun ...
Topic: High Performance Data Acquisition Systems Analog
... continuous in the time domain and therefore must be “sampled” at discrete points (and digitized) before the FFT algorithm can be used to process the data (see Figure 2). In short, the sampled waveform array corresponds to a table of values you might construct from a point-topoint measurement of the ...
... continuous in the time domain and therefore must be “sampled” at discrete points (and digitized) before the FFT algorithm can be used to process the data (see Figure 2). In short, the sampled waveform array corresponds to a table of values you might construct from a point-topoint measurement of the ...
Continuous Phase Shift of Sinusoidal Signals Using Injection
... trigonometric calculations, the fundamental current , passing through the varactor diodes can be expressed as ...
... trigonometric calculations, the fundamental current , passing through the varactor diodes can be expressed as ...
harmonics - inceptislabs.com
... This graph is called a "time domain" plot. It shows you motion (vertical, or Yaxis) over time (horizontal, or X-axis). The name “time domain” comes from the X-axis being expressed as time. The numbers on the Y axis represent the position, or "amplitude" of the oscillation. This particular wave has ...
... This graph is called a "time domain" plot. It shows you motion (vertical, or Yaxis) over time (horizontal, or X-axis). The name “time domain” comes from the X-axis being expressed as time. The numbers on the Y axis represent the position, or "amplitude" of the oscillation. This particular wave has ...
Lab 11: Relaxation oscillators (version 1.5)
... data points total). Measure the oscillator output frequency on pin 6 using a calibrated scope probe and the standalone oscilloscope (do not use the Elvis scope). Be sure to have the scope on DC coupling. Record the square wave oscillation frequency for the various R3C time constants. It is a ...
... data points total). Measure the oscillator output frequency on pin 6 using a calibrated scope probe and the standalone oscilloscope (do not use the Elvis scope). Be sure to have the scope on DC coupling. Record the square wave oscillation frequency for the various R3C time constants. It is a ...
M5400 datasheet - Doble Engineering
... Use the Doble M5400 Sweep Frequency Response Analyzer to detect mechanical failure or movement of windings due to short circuits, mechanical stresses or transportation. Sweep Frequency Response Analysis is a proven technique, pioneered by Doble, for making accurate and repeatable measurements. The s ...
... Use the Doble M5400 Sweep Frequency Response Analyzer to detect mechanical failure or movement of windings due to short circuits, mechanical stresses or transportation. Sweep Frequency Response Analysis is a proven technique, pioneered by Doble, for making accurate and repeatable measurements. The s ...
Fig. 2-1 Agilent VEE Setup
... Create an oscilloscope instrument panel and reset it, then configure it for a timebase of 0.2 ms/div. Set the Channel 1 sensitivity to 2 v/div, and set the probe factor to 10 for both channels. Add a SENS-CH1 input terminal, and WF-CH1 and WF-CH2 output terminals (the latter produce the two waveform ...
... Create an oscilloscope instrument panel and reset it, then configure it for a timebase of 0.2 ms/div. Set the Channel 1 sensitivity to 2 v/div, and set the probe factor to 10 for both channels. Add a SENS-CH1 input terminal, and WF-CH1 and WF-CH2 output terminals (the latter produce the two waveform ...
expt10
... instead is adjust VB to match the DC level of the source, thus making the capacitor unnecessary. The output of the amplifier is taken from the collector through capacitor Cc, so that vout has a DC level of zero. The resistor RE provides negative feedback in the following way. If the base voltage VB ...
... instead is adjust VB to match the DC level of the source, thus making the capacitor unnecessary. The output of the amplifier is taken from the collector through capacitor Cc, so that vout has a DC level of zero. The resistor RE provides negative feedback in the following way. If the base voltage VB ...
SGA2163Z 数据资料DataSheet下载
... responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents, or other rights of third parties, resulting from its use. No license is granted by implication or otherwise under any patent or patent rights of RFMD. RFMD reserves the right to change comp ...
... responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents, or other rights of third parties, resulting from its use. No license is granted by implication or otherwise under any patent or patent rights of RFMD. RFMD reserves the right to change comp ...
UMZ-442-A16-G
... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
1950 , Volume v.1, n.8 , Issue April-1950
... the slot searched with a probe oper ated by a panel control. This control can be calibrated directly in phase angle at any one frequency. The phase angle at any other frequency is modified by the ratio of the second frequency to the first. To facilitate calculation, the phase dial is cali brated for ...
... the slot searched with a probe oper ated by a panel control. This control can be calibrated directly in phase angle at any one frequency. The phase angle at any other frequency is modified by the ratio of the second frequency to the first. To facilitate calculation, the phase dial is cali brated for ...
Bode plot
In electrical engineering and control theory, a Bode plot /ˈboʊdi/ is a graph of the frequency response of a system. It is usually a combination of a Bode magnitude plot, expressing the magnitude of the frequency response, and a Bode phase plot, expressing the phase shift. Both quantities are plotted against a horizontal axis proportional to the logarithm of frequency.