• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Magnetism and Electromagnetism
Magnetism and Electromagnetism

... i) if a current carrying conductor is in a magnetic field, the conductor will experience a force and will move if it is free to do so. The movement, magnetic field and the current are all at right angles to each other. ii) to reverse the direction of an electric motor we can either reverse the curre ...
A 1920s Style Colpitts Broadcast Receiver
A 1920s Style Colpitts Broadcast Receiver

... never seen it used in any regenerative receiver until, as a teenager in the late 1940s, I obtained a broadcast-band kit radio called the Electrokit No.1. It employed a 1D8GT tube with its triode section serving as a regenerative detector and its pentode section as an audio amplifier. The complete st ...
Lecture 10
Lecture 10

... displaced inside coil’s winding. So a magnetic circuit is created which has the major contribution in concentrating the magnetic field lines. In this way the magnetic flux increases, almost all the magnetic lines intersect the turns, in conclusion the coil’s inductance increases. • The magnetic mate ...
uhf/vhf/fm active color antenna installation and operating
uhf/vhf/fm active color antenna installation and operating

Dragonhide
Dragonhide

... What I can't get the scope that can dump pictures to do is to show the crosstalk between TCK and its neighbour wire in the cable; The scope that _can_ capture this is my old analog, and it shows roughly 100mV worst case crosstalk, independent of wether a 1m or 5m ribbon cable is used. Notes There ar ...
Resonant circuits – measuring inductance
Resonant circuits – measuring inductance

... (These power limits will not be exceeded by using normal 0-24 V power supplies or our function generators.) The capacitors tolerates at least 250 V. The inductors (coils) has maximum RMS currents of 240 mA (4.7 mH) resp. 210mA (1.8 mH). As the coils are wound on ferrite cores, a saturation phenomeno ...
TEP Earth`s magnetic field with Cobra4 Mobile
TEP Earth`s magnetic field with Cobra4 Mobile

... are connected in series (linkage of equally-numbered connections) and connected with the DC-generator by the rheostat and the multimeter used as ammeter. The Hall probe is to be fixed on the support rod with barrel base pointing inward toward the coil axis in the center of the Helmholtz arrangement. ...
Chapter 4 Transmission Media
Chapter 4 Transmission Media

... — Line of sight • Above 30Mhz • May be further than optical line of sight due to refraction • More later… ...
Product data sheet - Schneider Electric
Product data sheet - Schneider Electric

... GG fuse <= 10 A rating according to operational current for Ue <= 690 V ...
6 Coax Cable in t and f domains
6 Coax Cable in t and f domains

... 1. Now attach the long piece of cable back to channel 1, resetting channel 1 to a high impedance. What does the waveform on channel 1 look like compared to the one in the previous question? Explain. Sketch the voltage observed on channel 2 and compare it to that on channel 1. You should see two diff ...
Using Standard Transformers in Multiple Applications
Using Standard Transformers in Multiple Applications

LRS4 Data Sheet - ProAcousticsUsa.com
LRS4 Data Sheet - ProAcousticsUsa.com

... box with a minimum depth of 2.5" [6.4 cm]. Turn the power to the unit off until all connections are made. It is important to ensure that the Remote Ports are not subjected to sustained voltages outside the range of 0 to 5 volts DC or high levels of static. The device inputs are protected, however yo ...
NIRComponentLabelingConvention36
NIRComponentLabelingConvention36

... The label nearest the connector identifies the component or cable that is its mate. It will have two lines of text. If the connector mates with a cable it will have the mating cables ID. If the connector mates to a component, the first line will identify the enclosure/major assembly where the cable ...
Fluxmeter Measuring Procedures
Fluxmeter Measuring Procedures

... strengths can be directly displayed and conversion is not required. Even the standard model of this fluxmeter has a digital interface which makes it possible to control the unit remotely. A tolerance test function and a digital peak value indicator are also built in. All required accessories such as ...
TITARC H01N2-D
TITARC H01N2-D

... and in dry and damp conditions = The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC ...
Failure Mode and Effect Analysis of Cable Failures within a Fire
Failure Mode and Effect Analysis of Cable Failures within a Fire

...  electrical power supply (voltage level)  instrumentation cable  control cable  operational state (open- or closed-circuit) ...
Lec 04
Lec 04

... Any current will create a magnetic field, so in fact every current-carrying wire in a circuit acts as an inductor! All the loops' contribution to the magnetic field add together to make a stronger field. Unlike capacitors and resistors, practical inductors are easy to make by hand. One can for insta ...
Test Tube Activities at Ohio State (7/29/03)
Test Tube Activities at Ohio State (7/29/03)

... 8 HV channels with current monitoring, overcurrent trip HV cables, HV connector box Low voltage: +/-5 V, 300 mA in AL box Low voltage: +/-5 V near mini crate (FE board, diff. Receiver) Install signal cables (on their way to Charlie) -> Need to identify the location of a suitable FEC crate! – This de ...
02049
02049

... circuit board coil output signal is given in Figure 4a. The coil signal is different than the signal recorded by the laboratory CT since it represents derivation of current per time, a unique feature of Rogowski coils. This is important since the speed of current change can be used for fast protecti ...
Determining Relay Coil Inductance
Determining Relay Coil Inductance

... with magnetizing force which, in turn, is determined by coil voltage. For values most meaningful to the circuit designer, inductance should be measured under conditions that simulate actual relay service; that is, at rated voltage and current. Inductance with armature seated represents actual applic ...
Fire Protection Duct Fire protected cable
Fire Protection Duct Fire protected cable

... WIRING ACCESSORIES ...
Electrical Times article
Electrical Times article

... Specifications from commercial customers may vary widely - some customers accept British Standards such as BS7888, while others may require adherence to Cenelec Standards. Some organisations may even have their own internal standards. Customers may also have very exact requirements – relating to cab ...
Optical Phase Conductor
Optical Phase Conductor

PHY114 S11 Term Exam 3
PHY114 S11 Term Exam 3

... 3.89 A and is increasing at a rate of 3.62 As−1 , what is the potential drop across the coil at this moment?(8 points) • An alternating current of peak value of 1.5A and frequency 46Hz is passed through a coil with inductance of 392mH. What is the peak voltage? Ignore the resistance.(8 points) • You ...
CAT 6, CAT 6A, CAT 7 Shielded RJ45 Modular Plugs
CAT 6, CAT 6A, CAT 7 Shielded RJ45 Modular Plugs

... Although Primus Cable makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product ...
< 1 ... 66 67 68 69 70 71 72 73 74 76 >

Loading coil



A loading coil or load coil is an inductor that is inserted into an electronic circuit to increase its inductance. A loading coil is not a transformer to provide coupling to another other circuit. The term originated in the 19th century for inductors used to prevent signal distortion in long-distance telegraph transmission cables. The term is also used for inductors in radio antennas, or between the antenna and its feedline, to make an electrically short antenna resonant at its operating frequency.Loading coils are historically also known as Pupin coils after Mihajlo Pupin, especially when used for the Heaviside condition and the process of inserting them is sometimes called pupinization.The concept of loading coils was discovered by Oliver Heaviside in studying the problem of slow signalling speed of the first transatlantic telegraph cable in the 1860s. He concluded additional inductance was required to prevent amplitude and time delay distortion of the transmitted signal. The mathematical condition for distortion-free transmission is known as the Heaviside condition. Previous telegraph lines were overland or shorter and hence had less delay, and the need for extra inductance was not as great. Submarine communications cables are particularly subject to the problem, but early 20th century installations using balanced pairs were often continuously loaded with iron wire or tape rather than discretely with loading coils, which avoided the sealing problem.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report