• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Experiment
Experiment

... depending on the scale you use—e.g., a 12-volt scale will have four times more internal resistance than the 3-volt scale.) How does this percent difference compare to the accuracy of the meter? Note: You should have three different circuits [ 2), 3), and 4) ] along with four sets of calculations [ t ...
Week 8 - bYTEBoss
Week 8 - bYTEBoss

... Measurements that fall between these values are rounded off, affecting the accuracy of the reproduced signals This can be translated into increased dynamic range, better signalto-error ratio, more headroom and/or better resolution. Generally, the higher the bit depth, the more accurate the reproduct ...
EET 1131 Lab #13 Multivibrators
EET 1131 Lab #13 Multivibrators

... switches. The LED should light up for about two seconds and then go dark. Use the oscilloscope’s Channel 1 to display your trigger signal in the top half of the oscilloscope’s screen, and use Channel 2 to display the 555’s output in the bottom half. Trigger the one-shot and observe the output pulse ...
Lab6_EE422 - University of Kentucky College of Engineering
Lab6_EE422 - University of Kentucky College of Engineering

... permanent loss of information), while the signals can be filtered to exploit signal redundancies and reduce the impact of noise, there will always be a level of uncertainty in the received signal. Parameters extracted from signals denoting 1s and 0s must be sufficiently separated (i.e. amplitude, fr ...
07-NileshJoshi
07-NileshJoshi

... System is said to be causal if the present value of the output signal depends only on the present and or the past value of the input signal. Such a system is often referred to as being nonanticipatory, as the output doesn’t anticipate future value of the input. The if the resistor and capacitor are ...
guide for the user - Circuit Specialists
guide for the user - Circuit Specialists

... The mathematic functions include addition, subtract, multiply and division for CH1 and CH2. In this function, use the addition, subtraction, multiplication,division function and FFT to operate and analyze the waveform. Select source A and B. Then adjust the vertical scale and offset to view the math ...
Agilent U1251B and U1252B Handheld Digital Multimeter Quick
Agilent U1251B and U1252B Handheld Digital Multimeter Quick

... 3 Connect the red and black test leads to input terminals V (red) and COM (black) respectively. 4 Probe the test points and read the display. 5 If the reading is unstable or zero, press to select division of input signal frequency by 100. This accommodates a higher frequency range of up to 20 MHz. 6 ...
DAC_WangChen
DAC_WangChen

... R-2R Ladder • resistances of the two branches at V1 both equal 2R so the current into this node will split evenly. • using only two resistor values, can generate a whole series of currents where In=2nI0. • From the voltage drop across the • horizontal resistors, we see that • Vn = 2RIn = 2n+1RI0 . ...
Evaluates:  MAX4104/MAX4105/MAX4304/MAX4305 MAX4104 Evaluation Kit ________________General Description ____________________________Features
Evaluates: MAX4104/MAX4105/MAX4304/MAX4305 MAX4104 Evaluation Kit ________________General Description ____________________________Features

... ±5.5V. For evaluation purposes, connect a +5V supply to the pad labeled VCC and a -5V supply to the pad labeled VEE. Connect the power-supply grounds to the pad marked GND. 2) Connect the output marked OUT to an oscilloscope through a terminated 50Ω cable. 3) Turn on the power supply. Apply a signal ...
Universal Current/Voltage Input Card
Universal Current/Voltage Input Card

... for a total of 256 potential analog input channels per system. The DBK15 features a 16-channel ­multiplexer and a programmable gain input amplifier. Its durable component sockets accept resistors that configure each channel for either current-to-voltage conversion or for voltage attenuation. The DBK ...
View File
View File

... Modern Digital Electronic Circuits Play an Important Role in Our Lives Practically, Each Everyday-use Product is a Digital System or at Least Incorporates One In Order to Better Understand The Operation of Digital Circuits, and be Able to Design, Verify and Test Them, It is Very Crucial to Reach to ...
VISIPAK V108 Temperature/Process Indicator
VISIPAK V108 Temperature/Process Indicator

... or all three alarms linked to one or both relays) and will operate in fail-safe (e.g., normally energized) or non fail-safe modes. Additionally, the unit can be configured for password protection, limiting operator access to any or all functions. An alarm blocking function is also configurable to pr ...
Physics 15b PSI Week 1: Introduction to Circuits and Equipment
Physics 15b PSI Week 1: Introduction to Circuits and Equipment

... Recall that absolute electrical potential (like absolute potential energy) has no meaning; only potential difference (a.k.a. “voltage”) has physical significance. As a matter of notation, we will generally use V to refer to a voltage (potential difference). Every apparatus used to measure voltage mu ...
Sampling Theory and Analog-to-Digital Conversion Basic
Sampling Theory and Analog-to-Digital Conversion Basic

... rate is 1Hz and you need to sample longer than 1s to obtain the full data set. • You may increase time to collect multiple repetitions. ...
LeCroy Current Probes Datasheet
LeCroy Current Probes Datasheet

... ADP300 is good for troubleshooting low frequency power devices and other circuits where the reference potential is elevated from the ground or the ground is unknown. The 100 MHz bandwidth ADP305 is designed for measuring the floating voltages found in today’s high-speed power electronics. PMA2 – Pow ...
PROJECT TITLE: MPOT – Music Playing over Tesla
PROJECT TITLE: MPOT – Music Playing over Tesla

... rather the same signal shapes. In our case the PWM generation circuit were operated in parallel output mode. So the two inputs exhibit the same signal shape. By using two UCC37321P MOSFET drivers for output 1 and its non-inverting version UCC37322P for output 2 the outputs exhibit different (invert ...
LAB 3 Tank circuit procedure and other information 1. Verify that the
LAB 3 Tank circuit procedure and other information 1. Verify that the

... 2. Calculate the resonant frequency of the LC tank in Figure 1 (a) with L = 300 H and C = 100 pF. Verify your calculation with LTSpice simulations. You should do an ac sweep around f0, and also a transient run to observe the natural response. Suggestion: use the fft to verify the frequency of the o ...
Physics 202 - La Salle University
Physics 202 - La Salle University

... the resistance is the ratio of Voltage to Current. If the graph of Current versus Voltage is a straight line (as it was for the resistor), then the ratio (resistance) is constant. Such a device is said to be linear or Ohmic. The graph of Current versus Voltage for the diode is not a straight line, a ...
TRANSISTOR AMPLIFIER
TRANSISTOR AMPLIFIER

... twisting action. ...
EELab2_Exp2_AD_Converter_V3 720KB Apr 18 2016 08:18:48
EELab2_Exp2_AD_Converter_V3 720KB Apr 18 2016 08:18:48

... which are usually continuous voltages or currents, to digital words used in computing, data transmission, information processing and storage, and control systems. We do this conversion because digital signals are easy to store, debug, and are almost free from noise. ...
Circuit Timing
Circuit Timing

...  Minimum: smallest. Many manufactures don’t specify this values in most moderate-speed logic families (74LS,74S TTL). Set to zero or 1/4~1/3 of typical delay if not specified. ...
CIRCUIT FUNCTION AND BENEFITS
CIRCUIT FUNCTION AND BENEFITS

... (Continued from first page) "Circuits from the Lab" are intended only for use with Analog Devices products and are the intellectual property of Analog Devices or its licensors. While you may use the "Circuits from the Lab" in the design of your product, no other license is granted by implication or ...
Sample and Hold  Circuit  for  Signal ...
Sample and Hold Circuit for Signal ...

... In deriving the sampling theorem for a signal g(t) it is assumed that the signal g(t) is strictly band-limited with no frequency components above ‘W’ Hz. However, a signal cannot be finite in both time and frequency. Therefore the signal g(t) must have infinite duration for its spectrum to be stric ...
No Slide Title
No Slide Title

... Fuel consumption ...
Experiment 2 - Portal UniMAP
Experiment 2 - Portal UniMAP

... Output offset voltage is the dc voltage that appears at the output when both inputs are zero volts. The output offset voltage of an operational-amplifier is caused by input offset voltage, due to slightly mismatched transistors in the differential-amplifier input stage, and differences in input bias ...
< 1 ... 71 72 73 74 75 76 77 78 79 ... 97 >

Oscilloscope



An oscilloscope, previously called an oscillograph, and informally known as a scope, CRO (for cathode-ray oscilloscope), or DSO (for the more modern digital storage oscilloscope), is a type of electronic test instrument that allows observation of constantly varying signal voltages, usually as a two-dimensional plot of one or more signals as a function of time. Other signals (such as sound or vibration) can be converted to voltages and displayed.Oscilloscopes are used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope allows single events to be captured by the instrument and displayed for a relatively long time, allowing observation of events too fast to be directly perceptible.Oscilloscopes are used in the sciences, medicine, engineering, and telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.Before the advent of digital electronics, oscilloscopes used cathode ray tubes (CRTs) as their display element (hence were commonly referred to as CROs) and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal. CROs were later largely superseded by digital storage oscilloscopes (DSOs) with thin panel displays, fast analog-to-digital converters and digital signal processors. DSOs without integrated displays (sometimes known as digitisers) are available at lower cost and use a general-purpose digital computer to process and display waveforms.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report