• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Lecture Circuits
Lecture Circuits

... The last term on the left side represents the potential difference across the capacitor. The term is negative because the capacitor's top plate, which is connected to the battery's positive terminal, is at a higher potential than the lower plate. Thus, there is a drop in potential as we move down th ...
Slide 1
Slide 1

... The last term on the left side represents the potential difference across the capacitor. The term is negative because the capacitor's top plate, which is connected to the battery's positive terminal, is at a higher potential than the lower plate. Thus, there is a drop in potential as we move down th ...
Integrator Op Amp Amplifier Circuit Diagram
Integrator Op Amp Amplifier Circuit Diagram

... The rate at which the output voltage increases (the rate of change) is determined by the value of the resistor and the capacitor, "RC time constant". By changing this RC time constant value, either by changing the value of the Capacitor, C or the Resistor, R, the time in which it takes the output vo ...
RLC Series Circuit
RLC Series Circuit

... therefore it will be difficult to measure this angle at frequencies that are very close to resonance. Above resonance the impedance is more inductive than capacitive and the Current will LAG the Voltage. Below resonance the impedance is more capacitive than inductive and the Current will LEAD the Vo ...
Digital Circuit I (EEI 101)
Digital Circuit I (EEI 101)

... Most waveforms encountered in digital systems are composed of series of pulses, sometimes called pulse trains, and can be classified as either periodic or nonperiodic. A periodic pulse waveform is one that repeats itself at a fixed interval, called a period (T). The frequency (f) is the rate at whic ...
Experiment 2b: TVS, Simulation using Scope
Experiment 2b: TVS, Simulation using Scope

... l. Ideal AC meters measure AC frequencies from near 0 Hz (almost DC) to way higher than any frequency our lab equipment can produce (about 5megHz maximum). But our lab meters are not that good. So, how good are they – what range of frequencies will each type of our lab meters measure when set to mea ...
Comdyna Model GP-6 Analog Computer, Serial Number 794
Comdyna Model GP-6 Analog Computer, Serial Number 794

... switch to POT SET, and depress the IC mode control push button. a. Position the Y/POT ADDRESS rotary switch to the number of the pot that you wish to set, and the digital voltmeter display (DVM) will show the current value of that pot (0 < value < 1). b. Rotate the knob (dial) of that pot CW or CCW ...
6 The Amplifier Experiment 6.1
6 The Amplifier Experiment 6.1

... If instead, we had connected the signal into channel A to the reference (with our input signal connected to B) we would get essentially the same result but with a minus sign, i.e. output = k × (A − B) = k × (0 − Vb ) = −k × Vb . For AC signals, this minus sign presents itself as a 180° phase shift i ...
07LAB5 - University of Guelph Physics
07LAB5 - University of Guelph Physics

... circuits. It is natural to ask if the two circuit types could be combined to perform subtraction or to find the difference between two voltages. A method of obtaining the difference between two voltages using one amplifier uses the circuit illustrated in Fig 5.1. ...


... voltage but is insensitive to the average voltage. This mode is convenient for most sine wave measurements. It must be used to observe small variations of large voltages. The capacitor will produce a DC level shift for pulses (see notes Section 3.04). 5.3* DC INPUT. The DC mode uses a direct connect ...
Ai-762 Analog Test Instrument
Ai-762 Analog Test Instrument

... Teradyne’s Ai-762 analog test instrument allows systems integrators to create powerful, mixed-signal test equipment that yields lower costs for test systems and test programs. The Ai-762 is a standards-based analog test solution that provides high-performance and flexibility for Defense and Aerospac ...
Product data: Charge Amplifier
Product data: Charge Amplifier

... from the case, and therefore from the machine frame, ground loop interference problems are largely eliminated. When the 2634 is used with normal, single ended transducers, the microplug adaptor JJ 0207 supplied allows the use of normal, low-noise coaxial cables; this adaptor automatically grounds on ...
DC and Parametric Sweep
DC and Parametric Sweep

... 35) At the bottom of the window you may have to resize the cursor window to display data There are two cursors Y1 and Y2. Y1 is controlled with the left mouse and Y2 with the right. 36) Affiliate cursor Y1 with the left trace of V(Vo)by clicking on its trace icon (small shape – blue square) with the ...
Week 3 - Making the Right Connections
Week 3 - Making the Right Connections

... Analog Recording  Comes from the word “analogous” meaning “similar to” or “the same as”  The voltage changes coming from the microphone will have absolute correlation with the changes in air pressure caused by the sound wave that moved the diaphragm  The fluctuations in the magnetic field record ...
AD8508 数据手册DataSheet 下载
AD8508 数据手册DataSheet 下载

... The AD8508 are specified for both the industrial temperature range of −40°C to +85°C and the extended industrial temperature range of −40°C to +125°C. The AD8508 quad amplifiers are available in the 14-lead TSSOP package. ...
TekConnect Adapters - Liberty Test Equipment
TekConnect Adapters - Liberty Test Equipment

... Tektronix Highperformance Oscilloscopes This family of adapter systems provides less signal distortion and better performance than traditional connections used to move a signal from one environment to another, such as BNC to N or BNC to SMA. TCA75 Adapter (75 to 50 Ω) ...
C35-100 Bogen 35 - 100 Watt Mixer Amplifiers
C35-100 Bogen 35 - 100 Watt Mixer Amplifiers

... The amplifiers mix 3 inputs: 2 Mic and Tel, or 1 Mic, 1 Aux and Tel. A second telephone input can be added using an accessory transformer. A built-in circuit provides microphone precedence over the Aux channel when a customersupplied SPST switch is actuated. The Tel input is signal activated and aut ...
Analog to Digital Converter
Analog to Digital Converter

... signals are converted to digital signals for display to user Slingbox converts analog input stream and rebroadcasts it across the internet in digital form CCDs use ADCs to process image data ...
Low-Voltage CMOS Analog Bootstrapped Switch For
Low-Voltage CMOS Analog Bootstrapped Switch For

... A general block diagram of the bootstrapped switch is shown in Fig. 2a. It consists of three main elements: the passtransistor (nMOS, pMOS or both types), a control signal generator and, finally, a clock booster. The control circuit generates a signal linearly related to the input signal. The purpos ...
- Krest Technology
- Krest Technology

... continuous-time comparators of a flash ADC implemented in the same technology [12]. To increase the bandwidth, inductive peaking and source degeneration with a bypass capacitor are applied. In the presented circuit, Bufout drives an output buffer, i.e., Bufmeas , which has been implemented to drive ...
SCT Data Sheet/Manual PDF
SCT Data Sheet/Manual PDF

... The Model SCT is a very versatile totalizing counter that can be adapted to a wide variety of counting, measuring, and position readout applications. Based on solid-state technology and circuit designs proven in tens of thousands of field applications, this unit exhibits outstanding noise immunity a ...
EE105 – Fall 2014 Microelectronic Devices and Circuits Introduction to Amplifiers
EE105 – Fall 2014 Microelectronic Devices and Circuits Introduction to Amplifiers

... Transistor Amplifiers dc and ac Analysis – Two Step Analysis •  dc analysis: –  Find dc equivalent circuit by replacing all capacitors by open circuits and inductors by short circuits. –  Find Q-point from dc equivalent circuit by using appropriate large-signal transistor model. •  ac analysis: –  ...
Evaluates: MAX4200/MAX4201/MAX4202 MAX4201 Evaluation Kit ________________General Description ____________________________Features
Evaluates: MAX4200/MAX4201/MAX4202 MAX4201 Evaluation Kit ________________General Description ____________________________Features

... maximum to the SMA connector marked IN+. 4) Verify the output signal on the oscilloscope. (Note: When using a 50Ω terminated oscilloscope input, the output amplitude observed on the oscilloscope will be half that on the input. This is due to the voltage divider formed by the internal 50Ω back-termin ...
Wireless Communications and Networks
Wireless Communications and Networks

... Conversion permits use of modern digital transmission and switching equipment ...
TS1003 Demo Board
TS1003 Demo Board

... using or intending to use the Silicon Laboratories products. Characterization data, available modules and peripherals, memory sizes and memory addresses refer to each specific device, and "Typical" parameters provided can and do vary in different applications. Application examples described herein a ...
< 1 ... 68 69 70 71 72 73 74 75 76 ... 97 >

Oscilloscope



An oscilloscope, previously called an oscillograph, and informally known as a scope, CRO (for cathode-ray oscilloscope), or DSO (for the more modern digital storage oscilloscope), is a type of electronic test instrument that allows observation of constantly varying signal voltages, usually as a two-dimensional plot of one or more signals as a function of time. Other signals (such as sound or vibration) can be converted to voltages and displayed.Oscilloscopes are used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope allows single events to be captured by the instrument and displayed for a relatively long time, allowing observation of events too fast to be directly perceptible.Oscilloscopes are used in the sciences, medicine, engineering, and telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.Before the advent of digital electronics, oscilloscopes used cathode ray tubes (CRTs) as their display element (hence were commonly referred to as CROs) and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal. CROs were later largely superseded by digital storage oscilloscopes (DSOs) with thin panel displays, fast analog-to-digital converters and digital signal processors. DSOs without integrated displays (sometimes known as digitisers) are available at lower cost and use a general-purpose digital computer to process and display waveforms.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report