Braking Module / braking resistor
... In converters with no regenerative feedback capability, the energy that occurs in the drive train under regenerative conditions is fed back to the DC link where it is reduced via braking resistors. The braking resistor is connected to the Braking Module. The distance between the Braking Module and b ...
... In converters with no regenerative feedback capability, the energy that occurs in the drive train under regenerative conditions is fed back to the DC link where it is reduced via braking resistors. The braking resistor is connected to the Braking Module. The distance between the Braking Module and b ...
HP MSR4000 Series
... Ethernet Virtual Interconnect (EVI) EVI is a MAC-in-IP technology that provides Layer 2 connectivity between distant Layer 2 network sites across an IP routed network. It is used for connecting geographically dispersed sites of a virtualized large-scale data center that requires Layer 2 adjacency. V ...
... Ethernet Virtual Interconnect (EVI) EVI is a MAC-in-IP technology that provides Layer 2 connectivity between distant Layer 2 network sites across an IP routed network. It is used for connecting geographically dispersed sites of a virtualized large-scale data center that requires Layer 2 adjacency. V ...
Multicast Rutorial r3
... – SONET and ATM are still applicable but are now rarely deployed on new installations. – Ethernet is the most common technology due to the wide range of affordable products available from many manufacturers and the familiarity with Ethernet and IP technology. – The components more commonly used to b ...
... – SONET and ATM are still applicable but are now rarely deployed on new installations. – Ethernet is the most common technology due to the wide range of affordable products available from many manufacturers and the familiarity with Ethernet and IP technology. – The components more commonly used to b ...
PDF - Complete Book (2.54 MB)
... You can use the ip default-gateway global configuration command to define a default gateway when IP routing is disabled on a device. For instance, if a device is a host, you can use this command to define a default gateway for the device. You can also use this command to transfer a Cisco software im ...
... You can use the ip default-gateway global configuration command to define a default gateway when IP routing is disabled on a device. For instance, if a device is a host, you can use this command to define a default gateway for the device. You can also use this command to transfer a Cisco software im ...
2-kW Electric Power Transmission Training Systems - Lab-Volt
... SERIES 8059 – 220 V – 50 Hz VERSION understandable by anyone who has foundational knowledge of electricity. The 2-kW Electric Power Transmission Training Systems are available in four versions. Model 8059-2 is a complete system using analog meters to perform the measurements. Model 8059-4 is also a ...
... SERIES 8059 – 220 V – 50 Hz VERSION understandable by anyone who has foundational knowledge of electricity. The 2-kW Electric Power Transmission Training Systems are available in four versions. Model 8059-2 is a complete system using analog meters to perform the measurements. Model 8059-4 is also a ...
Dimension ES-4024 Ethernet Switch: User`s Guide
... Trademarks mentioned in this publication are used for identification purposes only and may be properties of their respective owners. ...
... Trademarks mentioned in this publication are used for identification purposes only and may be properties of their respective owners. ...
Exelon Energy Delivery Interconnection Guidelines greater than 2
... necessary to interconnect the generation to the T&D System, as requested by the GIC. In order to perform such an analysis, EED will require technical information on the GIC generator(s) and proposed interconnection location to the system. In the case where the customer wishes to participate in the P ...
... necessary to interconnect the generation to the T&D System, as requested by the GIC. In order to perform such an analysis, EED will require technical information on the GIC generator(s) and proposed interconnection location to the system. In the case where the customer wishes to participate in the P ...
1.0 Introduction The Particulars of Work and
... in as a Visitor to site and should present themselves to the Security gate house. The Annexure 1 shall be completed and forwarded to The Principal representative named below 24 hours prior to the meeting. Proof of identity will be required prior to entry. NB: If details as required above are not sup ...
... in as a Visitor to site and should present themselves to the Security gate house. The Annexure 1 shall be completed and forwarded to The Principal representative named below 24 hours prior to the meeting. Proof of identity will be required prior to entry. NB: If details as required above are not sup ...
Intrinsically Safe Interfaces - Isolators
... On a worldwide basis, Original Equipment Manufacturers are continuously looking to expand their markets for existing and new system designs. When market opportunities arise that require ATEX or IEC certification for markets, such as Europe, the Middle East, Asia and Russia, R. STAHL is the preferred ...
... On a worldwide basis, Original Equipment Manufacturers are continuously looking to expand their markets for existing and new system designs. When market opportunities arise that require ATEX or IEC certification for markets, such as Europe, the Middle East, Asia and Russia, R. STAHL is the preferred ...
Liebert eXM User Manual–50-250kVA, 480V, 50/60Hz ®
... Cable entry locations, 50-200kVA model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable entry locations, 250kVA model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cabinet arrangement . . . . . . . . . . . ...
... Cable entry locations, 50-200kVA model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable entry locations, 250kVA model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cabinet arrangement . . . . . . . . . . . ...
Carlo Gavazzi Product Overview
... they are conductive or non-conductive. The patented and proven TripleshieldTM design has become the standard all other capacitive Automation Components proximity sensors are measured against. Now in its fourth generation, TripleshieldTM provides outstanding electromagnetic immunity and protection ag ...
... they are conductive or non-conductive. The patented and proven TripleshieldTM design has become the standard all other capacitive Automation Components proximity sensors are measured against. Now in its fourth generation, TripleshieldTM provides outstanding electromagnetic immunity and protection ag ...
DRAFT 0400 Installation Standard
... between the parties relating to its subject matter during the term of this Agreement. No modification to this Agreement will be binding, unless in writing and signed by an authorized representative of each party. Licensee may not assign or transfer this Agreement or any rights granted hereunder, by ...
... between the parties relating to its subject matter during the term of this Agreement. No modification to this Agreement will be binding, unless in writing and signed by an authorized representative of each party. Licensee may not assign or transfer this Agreement or any rights granted hereunder, by ...
PDF
... and other cell-site equipment. It transparently and efficiently transports cell-site voice, data, and signaling traffic over IP using traditional T1 and E1 circuits, as well as alternative backhaul networks such as Carrier Ethernet and DSL, Ethernet in the First Mile (EFM), and WiMAX. It also suppor ...
... and other cell-site equipment. It transparently and efficiently transports cell-site voice, data, and signaling traffic over IP using traditional T1 and E1 circuits, as well as alternative backhaul networks such as Carrier Ethernet and DSL, Ethernet in the First Mile (EFM), and WiMAX. It also suppor ...
PowerWAVE 6000 Series 3 60
... avoids a single point of failure that can exist in other, more traditional, parallel systems. Parallel system expansion Most data centres present a low initial power demand which increases as the data centre grows to its full capacity; and it is essential that any installed power protection system c ...
... avoids a single point of failure that can exist in other, more traditional, parallel systems. Parallel system expansion Most data centres present a low initial power demand which increases as the data centre grows to its full capacity; and it is essential that any installed power protection system c ...
UPS Uninterruptible Power Supply Adira (10 kVA, 20 kVA 3
... The packaging plays no role as fall protection, so all fallen devices must be checked by EFFEKTA Regeltechnik GmbH before commissioning. The device may not be transported or stored upside-down. ...
... The packaging plays no role as fall protection, so all fallen devices must be checked by EFFEKTA Regeltechnik GmbH before commissioning. The device may not be transported or stored upside-down. ...
super trouper ii
... mounted to the yoke pivot studs (see Figure 6, Item 2) are designed to bear the weight of the spotlight and base. This permits assembling the spotlight on the floor and later hoisting it to an overhead spotlight position. THE FOLDING BASE ASSEMBLY is shipped collapsed, and requires only folding the ...
... mounted to the yoke pivot studs (see Figure 6, Item 2) are designed to bear the weight of the spotlight and base. This permits assembling the spotlight on the floor and later hoisting it to an overhead spotlight position. THE FOLDING BASE ASSEMBLY is shipped collapsed, and requires only folding the ...
mn-lcs4 r1
... meaning ‘is BUC A power supply on or off?’), the target would respond with BSA=x, where x represents the state in question, 1 being on and 0 being off. Second, if the controller sends an instruction to set a parameter to a particular value, then, providing the value sent in the argument is valid, th ...
... meaning ‘is BUC A power supply on or off?’), the target would respond with BSA=x, where x represents the state in question, 1 being on and 0 being off. Second, if the controller sends an instruction to set a parameter to a particular value, then, providing the value sent in the argument is valid, th ...
PDF
... Introduction to the Cisco ATA Analog Telephone Adaptor The Cisco ATA is an analog telephone adaptor that allows traditional analog telephones to operate on IP-based telephony networks. The Cisco ATA supports two voice ports, each with its own independent telephone number. Two Cisco ATA products are ...
... Introduction to the Cisco ATA Analog Telephone Adaptor The Cisco ATA is an analog telephone adaptor that allows traditional analog telephones to operate on IP-based telephony networks. The Cisco ATA supports two voice ports, each with its own independent telephone number. Two Cisco ATA products are ...
MGETM GalaxyTM 5000
... The MGE™ Galaxy™ 5000 range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS. APC by Schneider Electric pays great attention to the environmental impact of its products. Measures that have made MGE ...
... The MGE™ Galaxy™ 5000 range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS. APC by Schneider Electric pays great attention to the environmental impact of its products. Measures that have made MGE ...
Cisco Enhances per- IPSec Tunnel QoS, IOS Firewall Security for Unified
... Voice, MPLS, and IP Services Integrates a portfolio of new capabilities, including security, voice, and IP services, with powerful hardware support Delivers advanced services for Enterprise and access customers Series of regularly scheduled individual technology releases, each of which delivers aggr ...
... Voice, MPLS, and IP Services Integrates a portfolio of new capabilities, including security, voice, and IP services, with powerful hardware support Delivers advanced services for Enterprise and access customers Series of regularly scheduled individual technology releases, each of which delivers aggr ...
Power over Ethernet
Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.