Deploying the Dell Force10 MXL into a Cisco Nexus Network
... environment: running PVST with discreet LAGs connected to separate top-of-rack switches as covered in Trunk Port Uplink Configuration with Per-VLAN Spanning Tree and running PVST with a single LAG connected across two top-of-rack switches that are using a Multi-chassis LAG as covered in Trunk Port U ...
... environment: running PVST with discreet LAGs connected to separate top-of-rack switches as covered in Trunk Port Uplink Configuration with Per-VLAN Spanning Tree and running PVST with a single LAG connected across two top-of-rack switches that are using a Multi-chassis LAG as covered in Trunk Port U ...
super trouper ii - Schell Scenic Studio, Inc.
... to the floor or platform. If it is desired to have the unit portable, when operating, the (4) leveling feet must be adjusted down until the entire weight of the spotlight has been shifted from the casters to the leveling feet. THE INNER TUBE below the support yoke is drilled with three holes to perm ...
... to the floor or platform. If it is desired to have the unit portable, when operating, the (4) leveling feet must be adjusted down until the entire weight of the spotlight has been shifted from the casters to the leveling feet. THE INNER TUBE below the support yoke is drilled with three holes to perm ...
EN_Wiring manual
... The device must be installed in a place with limited access. The device must be connected to an AC power supply with Protective Earthing: Phase or Live line (L) – black or brown cable, Neutral line (N) – blue cable, Protective Earth line (PE) – green cable with a vertical yellow dash. Double isolate ...
... The device must be installed in a place with limited access. The device must be connected to an AC power supply with Protective Earthing: Phase or Live line (L) – black or brown cable, Neutral line (N) – blue cable, Protective Earth line (PE) – green cable with a vertical yellow dash. Double isolate ...
VESR90x Serial Server
... Connecting ESERV-1xT Serial Servers to Serial Devices ................................................................................... 8 Connecting the ESERV-11T......................................................................................................................................9 ...
... Connecting ESERV-1xT Serial Servers to Serial Devices ................................................................................... 8 Connecting the ESERV-11T......................................................................................................................................9 ...
User Manual
... This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiat ...
... This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiat ...
A. General - Rules and standards
... vented types and one for dry types. The limit for battery size located in electrical assemblies has been increased to 5kVAh. When the assembly is mechanically ventilated the upper limit for installation in the battery room has been increased to 100 kVAh. — I403 b): Text concerning the acceptance of ...
... vented types and one for dry types. The limit for battery size located in electrical assemblies has been increased to 5kVAh. When the assembly is mechanically ventilated the upper limit for installation in the battery room has been increased to 100 kVAh. — I403 b): Text concerning the acceptance of ...
ENERGY LABORATORY
... Guided Practices, Self-evaluation (exam), Video and Statistical analysis. Notes: 1) Multipost option: This module is for 20 students post, but we can recommend the number of units for 30 students working simultaneously. 2)Supply conditions included: a) Technical conditions: - Laboratories adaptation ...
... Guided Practices, Self-evaluation (exam), Video and Statistical analysis. Notes: 1) Multipost option: This module is for 20 students post, but we can recommend the number of units for 30 students working simultaneously. 2)Supply conditions included: a) Technical conditions: - Laboratories adaptation ...
6400LF EdgeMarc Brochure
... The EdgeMarc Series 6400 converged network ing router provides the demarcation point for real-time, interactive IP services. The EdgeMarc 6400 is used in demanding environments and available in redundant AC or DC power supply configurations. Additionally the 6400 is RoHS (Restriction of certain Haza ...
... The EdgeMarc Series 6400 converged network ing router provides the demarcation point for real-time, interactive IP services. The EdgeMarc 6400 is used in demanding environments and available in redundant AC or DC power supply configurations. Additionally the 6400 is RoHS (Restriction of certain Haza ...
PCCE - Cisco Live
... Understanding of the Cisco Unified Wireless Networking for enterprise deployment scenarios. In this course, you will learn the basics of how to install, configure, operate, and maintain a wireless network, both as an add-on to an existing wireless LAN (WLAN) and as a new Cisco Unified Wireless Netwo ...
... Understanding of the Cisco Unified Wireless Networking for enterprise deployment scenarios. In this course, you will learn the basics of how to install, configure, operate, and maintain a wireless network, both as an add-on to an existing wireless LAN (WLAN) and as a new Cisco Unified Wireless Netwo ...
LF-Series Flowmeters
... The maximum cable length between the sensor and the power supply depends on the wire size, as shown in Table 2-1. The wire must be sized to provide a minimum of 15 V at the sensor. See the discussion in Section 5.4.1. ...
... The maximum cable length between the sensor and the power supply depends on the wire size, as shown in Table 2-1. The wire must be sized to provide a minimum of 15 V at the sensor. See the discussion in Section 5.4.1. ...
16-Port Bonded SHDSL
... provides up to eight pairs of SHDSL or e.SHDSL to be bonded together using Ethernet in the First Mile (EFM) to deliver up to 45Mbps to the customer. The Total Access 3000 EFM solution is certified to MEF (Metro Ethernet Forum) four and fourteen. The front panel is equipped with an LED for each port ...
... provides up to eight pairs of SHDSL or e.SHDSL to be bonded together using Ethernet in the First Mile (EFM) to deliver up to 45Mbps to the customer. The Total Access 3000 EFM solution is certified to MEF (Metro Ethernet Forum) four and fourteen. The front panel is equipped with an LED for each port ...
Feature Description
... known as streams, from each of the transmit antennas that results in the space dimension being reused, or multiplexed. If the transmitter is equipped with Ntx antennas and the receiver has Nrx ...
... known as streams, from each of the transmit antennas that results in the space dimension being reused, or multiplexed. If the transmitter is equipped with Ntx antennas and the receiver has Nrx ...
PowerFlex 700H and 700S AC Drives, Frames 9...14 Installation
... operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustment ...
... operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustment ...
AVR STK500 User Guide
... program in the AT90S8515 is similar to the example application code described in Section 9. Connect the LEDs and switches and power up the STK500 to run the test program in the AT90S8515. Use the supplied 10-pin cables to connect the header marked “PORTB” with the header marked “LEDS”, and connect t ...
... program in the AT90S8515 is similar to the example application code described in Section 9. Connect the LEDs and switches and power up the STK500 to run the test program in the AT90S8515. Use the supplied 10-pin cables to connect the header marked “PORTB” with the header marked “LEDS”, and connect t ...
TAS5630B - Texas Instruments
... PurePath HD technology enables traditional ABamplifier performance (< 0.03% THD) levels while providing the power efficiency of traditional class-D amplifiers. Unlike traditional class-D amplifiers, the distortion curve does not increase until the output levels move into clipping. PurePath HD techno ...
... PurePath HD technology enables traditional ABamplifier performance (< 0.03% THD) levels while providing the power efficiency of traditional class-D amplifiers. Unlike traditional class-D amplifiers, the distortion curve does not increase until the output levels move into clipping. PurePath HD techno ...
GTAW Lesson Plan - Jc097.k12.sd.us
... shock. Therefore, the work area must be dry and the operator must be in a dry area. The hazard of electrical shock is one of the most serious risks for a welder. This shock can take two forms: primary voltage shock, which is the most serious and comes from the input voltage. If you touch a lead insi ...
... shock. Therefore, the work area must be dry and the operator must be in a dry area. The hazard of electrical shock is one of the most serious risks for a welder. This shock can take two forms: primary voltage shock, which is the most serious and comes from the input voltage. If you touch a lead insi ...
Cisco IP SLA`s
... • Enterprise will verify SP SLAs by using access router edge to edge measurements Enterprise may provide restricted Simple Network Management Protocol (SNMP) (RTT, Latency, QoS) visibility into Access router for Service Provider Service Provider with restricted access can report SLA as a service bac ...
... • Enterprise will verify SP SLAs by using access router edge to edge measurements Enterprise may provide restricted Simple Network Management Protocol (SNMP) (RTT, Latency, QoS) visibility into Access router for Service Provider Service Provider with restricted access can report SLA as a service bac ...
PDF
... data-reduction techniques, but fluctuating network performance can still affect applications. Cisco Performance Routing (PfR) addresses network performance problems by allowing the network to intelligently choose a path that meets the current requirements of application performance. In addition, thi ...
... data-reduction techniques, but fluctuating network performance can still affect applications. Cisco Performance Routing (PfR) addresses network performance problems by allowing the network to intelligently choose a path that meets the current requirements of application performance. In addition, thi ...
Florida Department of Transportation
... Ensure that the voltage to the LED modules and their associated electronics does not exceed 25 VDC. Ensure that there are a minimum of two, and a maximum of four, power supplies that are wired in a parallel configuration for redundancy. Ensure that multiple power supplies are used to provide power t ...
... Ensure that the voltage to the LED modules and their associated electronics does not exceed 25 VDC. Ensure that there are a minimum of two, and a maximum of four, power supplies that are wired in a parallel configuration for redundancy. Ensure that multiple power supplies are used to provide power t ...
Power over Ethernet
Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.