• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Anant Kumar Tiwari, Miss. Durga Sharma, Mr.Vijay Kumar Sharma
Anant Kumar Tiwari, Miss. Durga Sharma, Mr.Vijay Kumar Sharma

... a industries which can be managed by power factor correction of electrical loads. Earlier the power factor correction was done by adjusting the capacitive bank manually [1]. The automated power factor corrector (APFC) using capacitive load bank is helpful in providing the power factor correction. Pr ...
moplt124
moplt124

... system of the Small Isochronous Ring (SIR) developed and built at the National Superconducting Cyclotron Laboratory (NSCL) at Michigan State University (MSU). SIR is a small-scale experiment that simulates the dynamics of intense beams in large accelerators. A 20 to 30 keV hydrogen or deuterium ion ...
Hoefer Power Supply
Hoefer Power Supply

... Power Supply Crossover A lamp next to the display indicates the parameter currently held constant. “Crossover” occurs when the second parameter limit is reached as system resistance changes. At this point the new parameter is held constant (the other lamp lights) and the previously unchanging param ...
Assembling a Computer
Assembling a Computer

... performance Set up boot sequence ...
Definition Crest Factor - AMETEK Programmable Power
Definition Crest Factor - AMETEK Programmable Power

... The crest factor and the peak currents of a load are important considerations in power source selection. Crest factor is defined as the ratio of peak value to rms value of a current waveform: ...
Floodless in SEATTLE: A Scalable Ethernet Architecture for Large Enterprises
Floodless in SEATTLE: A Scalable Ethernet Architecture for Large Enterprises

it right here
it right here

... Volt (V) A unit of electrical pressure. One volt is the electrical pressure that will cause one ampere of current to flow through one ohm of resistance. Voltage The term most often used in place of electromotive force, potential difference, or voltage drop. Designates the electric pressure existing ...
A Configuration Protocol for Embedded Networked Devices on Secure Wireless Networks
A Configuration Protocol for Embedded Networked Devices on Secure Wireless Networks

... Wireless devices do not have that luxury and require configuration at the data link level. In the common case of a Wi-Fi enabled laptop joining a wireless network, the user generally enters the SSID (network name) and optionally the WEP keys, and then uses higher-level configuration protocols. The S ...
Sales Conference Session for Simple Switcher & Tools
Sales Conference Session for Simple Switcher & Tools

... • These parameters are at odds with each other and need to be balanced for a designer’s needs • Tools are available to visualize tradeoffs and make it easier to get to the best solution for your design ...
Datasheet - Traco Power
Datasheet - Traco Power

... work en sure that t he m ain swit ch i s swi tched of f and prevented fro m be ing sw itched o n aga in. Non-observance, touch ing of an y live components or improper handling o f th is power supply ca n result i n death, sev ere personal in jury or sub stantial pro perty damage. Prop er and safe op ...
UPS Operating Modes: A Global Standard
UPS Operating Modes: A Global Standard

... All of these are predicated on the ability of the UPS to maintain these relationships within a specified range without resorting to battery power. By defining these relationships in this way, the focus is on WHAT the UPS actually does (and therefore, what problems it can address) as opposed to HOW it ...
Syllabus EE 435
Syllabus EE 435

... calculation. AC-DC converters: uncontrolled and fully-controlled single-phase and three-phase rectifiers, half-controlled rectifiers. AC-AC converters: cycloconverters, ac voltage controllers. DC-AC converters: single-phase and three-phase inverters. DC-DC converters: step-down, step-up, and step-do ...
C80216m-08/880  Project Title
C80216m-08/880 Project Title

... 12.x MS ID Privacy protection during Network Entry Each SS/MS has an X.509 certificate that is bound to the MAC address. The addition of a secondary certificate or use of an internal algorithm to (randomly) generate a key pair to protect MS ID privacy during network entry. This secondary key pair wo ...
Call for Papers Selected Areas in Communications Symposium
Call for Papers Selected Areas in Communications Symposium

... Scope and Motivation Cloud networking has emerged as a promising direction for cost-efficient, reliable and on-demand service provisioning across data communication networks. The Selected Areas in Communications Symposium – Cloud Networks provides an international track to present and develop scient ...
Multiplexed Amplifier
Multiplexed Amplifier

... maximum signal. On long distance it is not possible to get a steady signal but the alignment is optimal when the led flashes with the highest frequency. On short distance the sensitivity can be reduced using the potentiometer and then ...
BDTIC 900V CoolMOS™ C3 High Voltage Power MOSFET Using Charge Compensation Principle
BDTIC 900V CoolMOS™ C3 High Voltage Power MOSFET Using Charge Compensation Principle

... High Voltage Power MOSFET Using Charge Compensation Principle Infineon continues to deliver energy-saving CoolMOS™ power MOSFETs with extremely low static and dynamic power losses. Based on the device concept of charge compensation the on-resistance (RDS(on)) can be drastically reduced by a factor o ...
Power Inductors 8 Design Tips
Power Inductors 8 Design Tips

GUJARAT TECHNOLOGICAL UNIVERSITY  POWER ELECTRONICS (29) POWER CONVERTERS-I
GUJARAT TECHNOLOGICAL UNIVERSITY POWER ELECTRONICS (29) POWER CONVERTERS-I

Chapter 20: Quasi-Resonant Converters
Chapter 20: Quasi-Resonant Converters

... Zero-current and zero-voltage switching ZCS quasi-resonant switch: • Tank inductor is in series with switch; hence SW switches at zero current • Tank capacitor is in parallel with diode D2; hence D2 switches at zero voltage Discussion • Zero voltage switching of D2 eliminates switching loss arising ...
stereo-magazine - Rutherford Audio
stereo-magazine - Rutherford Audio

... T E S T C D P L AY E R  / I N T E G R AT E D A M P L I F I E R identical boards, separated in two channels, each comprises an input section, volume control, high-voltage amplifier and current amplifier stage. The circuit almost doing without negative feedback loop based of its quality relies on a c ...
1 - Oxford Schools | PowerSchool Learning
1 - Oxford Schools | PowerSchool Learning

... 8. Which of the following terms describes the address used at the Network layer? A. Physical B. Logical C. MAC D. Host E. Hexadecimal 9. Which of the following is the binary representation of the decimal number 110? A. 10000011 B. 01101110 C. 01111101 D. 11110111 E. 11101101 10. How is data packaged ...
Diode Lasers - Price
Diode Lasers - Price

... Current high-power, fiber-coupled diode laser systems are fabricated using laser diode bars with beamshaping optics. Although bar-based systems can couple impressive amounts of power into a fiber, they operate with low overall efficiency due to device cross-heating and poor fiber coupling efficiency ...
OnChipRegulators
OnChipRegulators

F2250 Power SyStem SimulatorS General Specifications teChNiCal
F2250 Power SyStem SimulatorS General Specifications teChNiCal

... temperature, up to full output power. Stable source operation in four quadrants: load power factor from 1 to 0, leading or lagging. The F2250 Family is supplied with a Certificate of Calibration traceable to the National Institute of Standards and Technology. ...
PXE Data Sheet
PXE Data Sheet

< 1 ... 431 432 433 434 435 436 437 438 439 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report