• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
doc
doc

... P3. With the voltage regulator working, you are now ready to power-up the rest of the PCB.  Carefully slide the shorting jumper over the two J21 header pins: this will connect 5 volts from the regulator to the Vcc supply bus on the board. This should illuminate LED1, located in the lower right of t ...
an1686 application note
an1686 application note

... Input Capacitor. Looking at the evaluation results presented in [1], it is reasonable to assume that with 75 W load the input power will be around 90 W. Estimating about 5 W power loss before the transformer, the power managed by the transformer will be 85 W. With the worst-case spread (-20 %) of C1 ...
RF5355 3.3V, 5GHz LINEAR POWER AMPLIFIER Features
RF5355 3.3V, 5GHz LINEAR POWER AMPLIFIER Features

... The RF5355 is a three-stage device with a minimum gain of 28dB in the 4.9GHz to 5.850GHz ISM band. The RF5355 is designed primarily for IEEE802.11a, IEEE802.11n, and IEEE802.16e in the 4.9GHz to 5.850GHz band where the available supply voltage and current are limited. This amplifier will operate to ...
Detecting, Identifying, and Correcting Power Quality Problems
Detecting, Identifying, and Correcting Power Quality Problems

Nuance B18-10: Specification - Nuance Battery and Tube Guitar
Nuance B18-10: Specification - Nuance Battery and Tube Guitar

IOSR Journal of Electronics and Communication Engineering (IOSR-JECE) ISSN: www.iosrjournals.org
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE) ISSN: www.iosrjournals.org

... harmonic damping, harmonic isolation, harmonic termination, reactive-power control for power factor correction and voltage regulation, load balancing, voltage-flicker reduction, and/or their combinations. Active filters can divided into single-phase active filters and three-phase active filters. Res ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

Aalborg Universitet transmission systems for passive networks
Aalborg Universitet transmission systems for passive networks

... By closing the busbar breaker between AC and DC lines, the power flow can transfer via AC and DC system simultaneously. The power sharing between AC and DC lines is an open issue. Currently, the power capability of DC system is set as constant, which is usually as full load demand, therefore when th ...
RS-422/232 CONVERTERS
RS-422/232 CONVERTERS

... 5.1.12 The port server shall utilize socket services to distribute the data without the need to load any software in any communicating device. Software may be loaded on a field maintenance computer to allow initial configuration of the devices. This software and applicable license shall be included ...
EE 1040104
EE 1040104

The Freedom of Wi-Fi
The Freedom of Wi-Fi

... The client communicate through Access Point. BSA-RF coverage provided by an AP. ESA-It consists of 2 or more BSA. ESA cell includes 10-15% overlap to allow roaming. ...
An Improved Power System Operation For Better Voltage
An Improved Power System Operation For Better Voltage

... reduces the losses. FACTS devices are used to control the voltage, current, impedance, phase angle and to damp the oscillations. To place these FACTS devices at optimal location with optimal rating in the electrical networks, some optimization techniques are proposed. In this paper Genetic algorithm ...
- 1 - HARMONICS AND HOW THEY RELATE TO POWER FACTOR
- 1 - HARMONICS AND HOW THEY RELATE TO POWER FACTOR

... than single-phase loads and, thus, higher distortion power factors. However, if three-phase loads employ phase control, their true power factors may be poor at reduced load levels due to low displacement power factors. It is important to point out that one cannot, in general, compensate for poor dis ...
PDF
PDF

... Sample One-Line RS-485 Network Connect up to 254 ControlKeeper lighting control panels and accessories 1. Daisy-chain all ControlKeeper lighting control panels using twisted pair (Belden #9841) or category 5 cable. 2. Lighting control network up to 4000 feet total length.If greater length is needed ...
MX Series data sheet - AMETEK Programmable Power
MX Series data sheet - AMETEK Programmable Power

... ease. Since many modern products use switching power supplies, they have a tendency to pull high repetitive peak currents. The MX30-3Pi can deliverup to 240 Amps of repetitive peak current (150 V AC range) per phase to handle three phase loads. Remote Control ...
Cummins Power Generation C900 D5 Diesel
Cummins Power Generation C900 D5 Diesel

... integrate the universal design, production and testing standard of Cummins, providing fully reliable and integrated power generation sy stems with optimum performance for applications in standby power, prime power and continuous operation. ...
PUB‐NLH‐547  Island Interconnected System Supply Issues and Power Outages  Page 1 of 8   
PUB‐NLH‐547  Island Interconnected System Supply Issues and Power Outages  Page 1 of 8   

... Please provide the minimum Effective Short Circuit Capacity (“ESCC”) at Soldiers  Pond at which the LIL will be expected to deliver:  ...
lecture
lecture

... 1.Multiple Access Links and Protocols Three types of “links”:  point-to-point (single wire, e.g. PPP, SLIP)  broadcast (shared wire or medium; e.g, Ethernet, Wavelan, etc.) ...
OptiSwitch® 940 Series - MV Communications Co., Ltd.
OptiSwitch® 940 Series - MV Communications Co., Ltd.

D_LKAT2_P
D_LKAT2_P

... DynAmp’s new LKAT2 Portable is a lightweight, extremely rugged and easy to use AC / DC measurement system for currents up to 150kA. Based on DynAmp’s well-proven 3rd Generation OLOP technology, primary measurement accuracy is 0.25% The typical system is offered with a variety of Head ‘Sides’ enablin ...
Development of Power Flow Model of Hybrid Power Flow Controller
Development of Power Flow Model of Hybrid Power Flow Controller

... Flow Controller (UPFC). The dynamic performance of the switching converter type FACTS devices is better than that of the variable impedance type FACTS devices [1]. Among the various FACTS devices, UPFC is the most comprehensive one [2]. It is capable of controlling voltage, impedance and phase angle ...
Multiple-Output, Variable-Output DC Power Supply
Multiple-Output, Variable-Output DC Power Supply

... The power supply will be built with a circuit board and basic circuit components, including transformers, resistors, inductors, capacitors, and diodes. Complicated components, such as the LM317T adjustable output, positive voltage regulator, will be purchased separately. The basic technical problem ...
On Current and Power Injection Models for Angle
On Current and Power Injection Models for Angle

80-6420-10/Rev. A/12-98 - GE Healthcare Life Sciences
80-6420-10/Rev. A/12-98 - GE Healthcare Life Sciences

Devtech Lighting Control Gear.cdr
Devtech Lighting Control Gear.cdr

< 1 ... 378 379 380 381 382 383 384 385 386 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report