• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Electro-Mechanical Terminology
Electro-Mechanical Terminology

... Egress Side - The side of an opening from which traffic exits. Electric Strike - An electro-mechanical door locking device (usually solenoid-operated) that will unlock the door when electrical power is applied to it. A fail-safe configuration will operate in the reverse condition (i.e., normally loc ...
PA4 rev1 - Knight Fire And Security
PA4 rev1 - Knight Fire And Security

Synchronous condenser solutions
Synchronous condenser solutions

SR Trace Heating Cable Brochure
SR Trace Heating Cable Brochure

... drains and rooftops, SR Trace is a self-regulating heating cable engineered to vary its heat output as the surrounding temperature changes; the colder it gets, the more heat is generated by the cable. Available in power densities of 3, 5 and 8 Watts per foot, all cables are UL Listed and CSA Certifi ...
RF_commissioning1 - Indico
RF_commissioning1 - Indico

... • Long-term power test (100 hours) If SPS type 800MHz power plant is used, most of the procedures will already be well defined ...
Dynamic power management for embedded system
Dynamic power management for embedded system

... Automatic selection of operating points as devices change states is a central feature of DPM. Embedded systems may not have a BIOS or machine abstraction layer to insulate the operating system from low-level device and power management. The most aggressive power management strategies will also re ...
EE595_Team1_P3_Fall07
EE595_Team1_P3_Fall07

... Market Price $490.00 Market price with mark-up of 40% Total Sales $490,000.00 Total sales for 1000 systems Profit Total Profit/ first year ...
Emergency services location configuration protocols
Emergency services location configuration protocols

... Patent Policy and Procedures: The contributor is familiar with the IEEE 802 Patent Policy and Procedures , including the statement "IEEE standards may include the known use of patent(s), including patent applications, provided the IEEE receives assura ...
AZ22308312
AZ22308312

Location Configuration
Location Configuration

... Patent Policy and Procedures: The contributor is familiar with the IEEE 802 Patent Policy and Procedures , including the statement "IEEE standards may include the known use of patent(s), including patent applications, provided the IEEE receives assura ...
Voice Synthesizer - Western Weather Group
Voice Synthesizer - Western Weather Group

... Phone. Typically a touch-tone phone, but a rotary phone can be used to receive a verbal report only when the report does not require user participation. Analog phone line. Some DBX office phone lines are digital and cannot be used with the COM320 Surge protector at the datalogger site if one is not ...
MODIS System Accessory Brochure PDF - Snap-on
MODIS System Accessory Brochure PDF - Snap-on

Dynatel™ 2273 Cable/Fault Locator
Dynatel™ 2273 Cable/Fault Locator

Presentation Slides - Electrical and Computer Engineering
Presentation Slides - Electrical and Computer Engineering

... and a tight tolerance crystal, which typically must be better than 25 ppm. ...
Diesel Generator Set Model DGHD 60 Hz
Diesel Generator Set Model DGHD 60 Hz

... Separately Excited Permanent Magnet Generator (PMG) System - This option uses an integral PMG to supply power to the voltage regulator. A PMG system generally has better motor-starting performance, lower voltage dip upon load application, and better immunity from problems with harmonics in the main ...
KV2 Audio EX12T Rental Manual
KV2 Audio EX12T Rental Manual

IOSR Journal of Computer Engineering (IOSR-JCE) e-ISSN: 2278-0661,p-ISSN: 2278-8727 PP 32-35 www.iosrjournals.org
IOSR Journal of Computer Engineering (IOSR-JCE) e-ISSN: 2278-0661,p-ISSN: 2278-8727 PP 32-35 www.iosrjournals.org

277 Volts to your Server? - Engineered Systems Magazine
277 Volts to your Server? - Engineered Systems Magazine

... lamps in the late 1890s allowed higher voltages to be used thus reducing losses. In Europe where development was after the US, the higher voltage was adopted. ...
Advantage of the use of an added driver source lead in discrete
Advantage of the use of an added driver source lead in discrete

IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)

... design of ARM processor-based embedded Ethernet interface is presented. In the design, an existing SPI serial device can be converted into a network interface peripheral to obtain compatibility with the network. The design mainly consists of SPI communication module, processor module and Ethernet in ...
Power on the move
Power on the move

... power quality. It is to help utilities meet these two challenges that ABB has built upon decades of technical achievements in high-voltage substation technologies with advanced degrees of compactness, availability and automation to expand its prefabricated and functionally integrated offerings into ...
101a-NK_Technologies_Power_Transducers
101a-NK_Technologies_Power_Transducers

... transformer is producing its maximum signal, the primary voltage is at the range maximum and power factor is at unity. For example, using the APT-480-5 A-120-420 with 400:5 current transformers, the transducer will produce 20 mA when there is 400 A through the CT and the primary voltage is 480. If t ...
GZ3612511256
GZ3612511256

... power manufacturing. The structure methodology found in this work will involve application layout with regard to aspect selection, increased equipment layout, computer simulation. This proposed research work will also presents an assessment regarding transformation, rectification, filtration and reg ...
Circuit Protection Solutions for Security and Fire Alarm Systems
Circuit Protection Solutions for Security and Fire Alarm Systems

... Figure 1. PPTC devices protect the circuit by going from a low-resistance state to a high-resistance state in response to an overcurrent or overtemperature condition. ...
User Manual ® Features
User Manual ® Features

< 1 ... 382 383 384 385 386 387 388 389 390 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report