• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Redi-Flo Variable Frequency Drive Manual
Redi-Flo Variable Frequency Drive Manual

... #3 and #4 for operation with generator only. WARNING: Do not let the generator run out of gas while powering the VFD. If it surges and creates excessive voltage, internal VFD damage could result. 3. If using a generator, start the generator and allow it to warm up. 4. If the generator has a circuit ...
William States Lee III Nuclear Station FSAR, Chapter 8 CHAPTER 8 ELECTRIC POWER
William States Lee III Nuclear Station FSAR, Chapter 8 CHAPTER 8 ELECTRIC POWER

... rated for the ultimate load and fault current levels to which the switchyard might be exposed. The nominal continuous current ratings of the installed equipment (based on a nominal operating temperature of key elements at 90 Deg C) is 3000 amperes for the 230 kV switchyard and 4000 amperes for the 5 ...


The display indication shall be in 2 languages
The display indication shall be in 2 languages

Supplementary Protectors (UL1077 mini circuit breakers) 2
Supplementary Protectors (UL1077 mini circuit breakers) 2

... Section 25 of UL1077 covers the requirements for supplemental protector short circuit testing and evaluation criteria. Short-circuit performance is one of the most important functions of an overcurrent protective device. Short circuits can impose enormous amounts of energy upon electrical installat ...
Insulation coordination studies
Insulation coordination studies

a CMOS, Low Voltage RF/Video, SPST Switch ADG751
a CMOS, Low Voltage RF/Video, SPST Switch ADG751

... and to grounding. Wire wrap boards, prototype boards and sockets are not recommended because of their high parasitic inductance and capacitance. The part should be soldered directly to a printed circuit board. A ground plane should cover all unused areas of the component side of the board to provide ...
Get PDF - IOS Press
Get PDF - IOS Press

... The electrical power generated by an oscillator is applied to the human body and the standard resistor. The difference in the voltage and the phase between the human body and the standard resistor is measured by a vector voltage comparator. Since the one side of the human body was electrically conne ...
Facility Master Specification Guide
Facility Master Specification Guide

The Polarization Cell Replacement (PCR)
The Polarization Cell Replacement (PCR)

Current transformer relaying accuracies
Current transformer relaying accuracies

... IEC 61869-2 protection (relaying) accuracy classes The classification scheme of IEC 61869-2 is substantially different from that of IEEE C57.13, but since the underlying physics are the same, the two systems are able to be correlated, at least in part. In IEC, the current transformer class of inter ...
ECE 309 - Clemson University
ECE 309 - Clemson University

... subject line, identification symbol, distribution notice, and attachment or enclosure notice. Most organizations, through regulations or through custom, have standard or semi-standard formats for the heading lines. Some common types of memo reports are the progress report and the status report. Thes ...
Noise-current Measurement — 1 Without - Renesas e
Noise-current Measurement — 1 Without - Renesas e

26 24 13 Switchboards
26 24 13 Switchboards

V. C. Summer Nuclear Station, Units 2 and 3 COL Application
V. C. Summer Nuclear Station, Units 2 and 3 COL Application

... The breaker-and-a-half configuration has multiple connections made between the buses. Each connection between the buses is made with three circuit breakers and two circuits (referred to as a bay). This arrangement allows for breaker maintenance without interruption of service. A fault on either bus ...
1 - University of Toronto
1 - University of Toronto

... j   0   0  and, (ii) the driven current amplitude is maximum, Imax= V0Q X C0 . The two observations can be considered to be the consequence of the fact that at resonance the loop impedance is pure resistance. It should be mentioned that although in the circuit considered the response current ...
IF 1684 Revision 1
IF 1684 Revision 1

... Figure 2 - Wiring Diagram ...
Electrical energy
Electrical energy

... that superconductors could revolutionise our methods of transportation. Powerful electromagnets can be made by winding superconductors into coils and passing electricity through them. These could be used to propel trains which float on air. This technology is called maglev (magnetic levitation) and ...
High Frequency Induction Welding
High Frequency Induction Welding

... Relationship between the plate voltage and plate current; and the relationship between plate voltage and grid current are nearly coincident with the rated impedance line. ...
P84025
P84025

... Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with these instructions at the time of installation and at least twice a year or more often and in accordance with loca ...
Electrical energy
Electrical energy

Installation Instruction Sheet for Vision Site Medium LED
Installation Instruction Sheet for Vision Site Medium LED

... IMPORTANT: READ BEFORE REMOVING FIXTURE FROM CARTON. RETAIN FOR FUTURE REFERENCE. SAFETY: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedur ...
ADM1070 数据手册DataSheet 下载
ADM1070 数据手册DataSheet 下载

... UV/OV Pin is proportional to board supply and is determined by external resistors. When the voltage on UV/OV falls below the undervoltage threshold of 0.86 V, the GATE Pin is driven low. When the voltage appearing at the UV/OV Pin rises above the overvoltage threshold of 1.97 V, the GATE Pin is also ...
Protection Relays Guide 2012
Protection Relays Guide 2012

SWITCHGEAR
SWITCHGEAR

... The switchgear shall be factory assembled and tested and comply with applicable industry standards. It shall be a coordinated design so that shipping groups are easily connected together at the site into a continuous line-up. Necessary connecting materials shall be furnished. All power circuit break ...
< 1 ... 83 84 85 86 87 88 89 90 91 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report