DG308A/DG309 Quad, SPST Analog Switches _______________General Description ____________________________Features
... (SPST) analog switches. The DG308A is normally open (SPST, NO), while the DG309 is normally closed (SPST, NC). Both parts feature fast switching speeds and low onresistance over the analog range. Other features include a turn-on time under 120ns, a turn-off time under 90ns, and a channel on-resistan ...
... (SPST) analog switches. The DG308A is normally open (SPST, NO), while the DG309 is normally closed (SPST, NC). Both parts feature fast switching speeds and low onresistance over the analog range. Other features include a turn-on time under 120ns, a turn-off time under 90ns, and a channel on-resistan ...
HARMONICS - Understanding the Facts
... In order to be able to analyze complex signals that have many different frequencies present, a number of mathematical methods were developed. One of the more popular is called the Fourier Transform. However, duplicating the mathematical steps required in a microprocessor or computer-based instrument ...
... In order to be able to analyze complex signals that have many different frequencies present, a number of mathematical methods were developed. One of the more popular is called the Fourier Transform. However, duplicating the mathematical steps required in a microprocessor or computer-based instrument ...
Fundamental Electricity Student Study Notes - Linn
... Depending on the sensitivity of the meter you might actually see a very small reading, for example 136 mV instead of .000V. When you read the meter display make sure you read not just the numbers but the units that the numbers represent. The trick is to watch the meter readout since it will change a ...
... Depending on the sensitivity of the meter you might actually see a very small reading, for example 136 mV instead of .000V. When you read the meter display make sure you read not just the numbers but the units that the numbers represent. The trick is to watch the meter readout since it will change a ...
Need to fix broken links [quote author=Mike Sokol link=topic
... time the blue voltage is higher than the red, and vice versa. Since there exists potential (voltage) between the two machines at these points, when the machines are connected together on a common bus, current will flow between the machines (cross current) even if there is no load. Note that because ...
... time the blue voltage is higher than the red, and vice versa. Since there exists potential (voltage) between the two machines at these points, when the machines are connected together on a common bus, current will flow between the machines (cross current) even if there is no load. Note that because ...
BD63801EFV
... Parasitic diodes occur inevitably in the structure of the IC, and the operation of these parasitic diodes can result in mutual interference among circuits, operational faults, or physical damage. Accordingly, conditions that cause these diodes to operate, such as applying a voltage lower than the GN ...
... Parasitic diodes occur inevitably in the structure of the IC, and the operation of these parasitic diodes can result in mutual interference among circuits, operational faults, or physical damage. Accordingly, conditions that cause these diodes to operate, such as applying a voltage lower than the GN ...
MAX1553 Evaluation Kit - Part Number Search
... Evaluating the MAX1553 Shutdown To place the part in low-power shutdown mode, short pins 1-2 of JU2. For normal operation, short pins 2-3 of JU2. Controlling LED Intensity LED intensity can be controlled using the BRT1 input. BRT1 can be used either as an analog or digital input. When using BRT1, re ...
... Evaluating the MAX1553 Shutdown To place the part in low-power shutdown mode, short pins 1-2 of JU2. For normal operation, short pins 2-3 of JU2. Controlling LED Intensity LED intensity can be controlled using the BRT1 input. BRT1 can be used either as an analog or digital input. When using BRT1, re ...
WP132001EN/ Old W240-11018
... to potentially damaging overloads prior to the BON fuse’s operation. One way of ensuring this is to check the maximum clear current of the BON fuse which must be less than or equal to 90% of the backup CL fuse’s minimum melt current at 300 seconds. When proper coordination is achieved the low curren ...
... to potentially damaging overloads prior to the BON fuse’s operation. One way of ensuring this is to check the maximum clear current of the BON fuse which must be less than or equal to 90% of the backup CL fuse’s minimum melt current at 300 seconds. When proper coordination is achieved the low curren ...
Questions
... 34. A lighting circuit in a house serves 6 rooms. If each room can have a maximum of 150 watts per ceiling lamp, what value of fuse should be used to protect the circuit? current = ...
... 34. A lighting circuit in a house serves 6 rooms. If each room can have a maximum of 150 watts per ceiling lamp, what value of fuse should be used to protect the circuit? current = ...
Week 13-14-Transf-SAB2032
... Power from plant/station is generated around 11-13-20-30kV (depending upon manufacturer and demand) This voltage is carried out at a distance to reach for utilization through transmission line system by step up transformer at different voltage levels depending upon distance and losses Its distributi ...
... Power from plant/station is generated around 11-13-20-30kV (depending upon manufacturer and demand) This voltage is carried out at a distance to reach for utilization through transmission line system by step up transformer at different voltage levels depending upon distance and losses Its distributi ...
Lecture 3
... A multiple stuck-at fault means that any set of lines is stuck-at some combination of (0,1) values. The total number of single and multiple stuck-at faults in a circuit with k single fault sites is 3k-1. A single fault test can fail to detect the target fault if another fault is also present, howeve ...
... A multiple stuck-at fault means that any set of lines is stuck-at some combination of (0,1) values. The total number of single and multiple stuck-at faults in a circuit with k single fault sites is 3k-1. A single fault test can fail to detect the target fault if another fault is also present, howeve ...
Transformer Failure Due to Circuit-Breaker
... (EMTP) consisting of the source, breaker, cable, and transformer, as shown in Fig. 5. The cable is represented by a Pi model consisting of the series impedance and half of the cable charging at each end. In some cases, multiple Pi models are used to represent the cable. The vacuum or SF-6 breaker is ...
... (EMTP) consisting of the source, breaker, cable, and transformer, as shown in Fig. 5. The cable is represented by a Pi model consisting of the series impedance and half of the cable charging at each end. In some cases, multiple Pi models are used to represent the cable. The vacuum or SF-6 breaker is ...
AN-812 APPLICATION NOTE
... Programming specifications require that the unit be powered at 5 V during programming. If the microcontroller is operated at a voltage smaller than 5 V, a switch or a two-position jumper must be added to select from system supply and programming supply (SW1). A three-position switch allows the circu ...
... Programming specifications require that the unit be powered at 5 V during programming. If the microcontroller is operated at a voltage smaller than 5 V, a switch or a two-position jumper must be added to select from system supply and programming supply (SW1). A three-position switch allows the circu ...
Electrical safety costs little … … a human life is priceless
... in medical locations. Contrary to an earthed system (TN system) there is no conductive connection between active conductors and the protective earthing conductor within the IT system. ...
... in medical locations. Contrary to an earthed system (TN system) there is no conductive connection between active conductors and the protective earthing conductor within the IT system. ...
Dynamic Testing of Generator Protection Using a Model Generator
... Saturation of main and relay CTs and switch-off transients are the main concerns when testing the stator differential protection. Particular attention must be paid to long-lasting external faults of small current magnitude but very long d.c. time constant. Small magnitude currents create small restr ...
... Saturation of main and relay CTs and switch-off transients are the main concerns when testing the stator differential protection. Particular attention must be paid to long-lasting external faults of small current magnitude but very long d.c. time constant. Small magnitude currents create small restr ...