• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Connected Equipment Guarantee Limited Lifetime Product Warranty
Connected Equipment Guarantee Limited Lifetime Product Warranty

general electrical equipment
general electrical equipment

Determination and Application of Practical Relaying
Determination and Application of Practical Relaying

... When the study to establish the original loadability parameters was performed, it was based on the 4-hour facility rating. The intent of the 150% factor applied to the Facility Rating in the loadability requirement was to approximate the 15-minute rating of the transmission line and add some additio ...
UCC5614 数据资料 dataSheet 下载
UCC5614 数据资料 dataSheet 下载

... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
MC1488 Quad Line Driver
MC1488 Quad Line Driver

... must be validated for each customer application by customer’s technical experts. Motorola does not convey any license under its patent rights nor the rights of others. Motorola products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the ...
BD82022FVJ
BD82022FVJ

... When excessive current flows due to output short-circuit or overload ringing occurs because of inductance between power source line and IC. This may cause bad effects on IC operations. In order to avoid this case, connect a bypass capacitor CIN across IN terminal and GND terminal of IC. 1µF or highe ...
Submersible Wastewater Pump Type ABS AS 0530 - 0841
Submersible Wastewater Pump Type ABS AS 0530 - 0841

... -- Do the non-return valves (where fitted) function easily? -- Have the hydraulics been vented in the case of dry installed pumps? ...
ABR1E301M - Schneider Electric
ABR1E301M - Schneider Electric

... ABR1E301M ...
If You have Problems
If You have Problems

Oregon 2011 NEC Code Change RV 4.12.2014 PLEASE DO NOT
Oregon 2011 NEC Code Change RV 4.12.2014 PLEASE DO NOT

Portfolio Template - Schuylkill Technology Center
Portfolio Template - Schuylkill Technology Center

Trouble Code: P0010 (2.4L L4 VIN B Auto)
Trouble Code: P0010 (2.4L L4 VIN B Auto)

Generator Protection
Generator Protection

Busbars and distribution
Busbars and distribution

1200V Large DIPIPM Version 6 Series Application Note
1200V Large DIPIPM Version 6 Series Application Note

... life time curves (Section 3.1.10) for safety design. (6) Vcc(prot) The maximum supply voltage for IGBT turning off safely in case of an SC fault. The power chip might be damaged if supply voltage exceeds this rating. (7) Tc position Tc (case temperature) is defined as the temperature just underneath ...
Fence Systems for Grazing Management 1
Fence Systems for Grazing Management 1

... poor. Whereas a deep silt loam soil may retain good conductivity at all times, drouthy non-conductive soils pose some special grounding problems. To enhance the effectiveness of electric fence in these environments, it may be appropriate to construct what is termed an earth-return fence system. In a ...
UCC281-5 数据资料 dataSheet 下载
UCC281-5 数据资料 dataSheet 下载

... shutdown pin which, when pulled low, turns off the regulator output and puts the device in a low current state. For the UCC381-ADJ version, a capacitor is required between the CT pin and GND to set the TON time during overcurrent according to the following (typical) equation: ...
Hammond Manufacturing Line Transformers
Hammond Manufacturing Line Transformers

... • Finished in a grey/beige color, textured powder paint with rubber feet installed. • NOTE 1: Due to the nature of ferroresonant designs - these units do produce audible noise. We have reduced this through careful design, but these units are NOT usable in an office environment. • NOTE 2: Thes ...
S2014, BME 101L: Applied Circuits Lab 5a Characterizing
S2014, BME 101L: Applied Circuits Lab 5a Characterizing

... of the impedance) and the DC resistance. In this lab you will measure both. The impedance is not really a single number though, but a function of frequency, and you will model the impedance of the loudspeaker as a combination of different linear components (inductors, resistors, and capacitors). The ...
FCPS-24F/FCPS-24FE Field Charger/Power Supply
FCPS-24F/FCPS-24FE Field Charger/Power Supply

Diagnostic Fault Information Perform the Diagnostic System Check
Diagnostic Fault Information Perform the Diagnostic System Check

Project code STCU/5388. Development, realisation and testing of the sample... phase shift transformer with thyristor control. Period of realisation 2011-2012....
Project code STCU/5388. Development, realisation and testing of the sample... phase shift transformer with thyristor control. Period of realisation 2011-2012....

Read Full Article  - ADB Airfield Solutions
Read Full Article - ADB Airfield Solutions

... Operation on higher crest factor CCR current wave shapes may not be possible with these other manufacturers—again, it pays to investigate this issue with all potential suppliers. It is also important for the design engineer to specify the desired performance requirements because, in a low bid market ...
How RF transformers work and how they are measured
How RF transformers work and how they are measured

... signal amplitude, in dB, between the two outputs of a center-tapped transformer using the center tap as a ground reference. Phase balance, sometimes called “unbalance”, is the absolute value of the difference in signal phase between the two outputs of a center-tapped transformer using the center tap ...
Accutrack Relays
Accutrack Relays

... of excellence established by GRS with the innovation of Alstom to perfect the technology, first introduced nearly 80 years ago. Today, Alstom relays are considered to be the standard in the industry. Available in a wide range of types and configurations, Alstom relays improve reliability, reduce mai ...
< 1 ... 56 57 58 59 60 61 62 63 64 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report