• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
FTZ5.6EFH
FTZ5.6EFH

... The products listed in this document are designed to be used with ordinary electronic equipment or devices (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devic ...
A4 - Keri Systems
A4 - Keri Systems

Gas-insulated switchgear up to 420 kV, 63 kA, 5000 A
Gas-insulated switchgear up to 420 kV, 63 kA, 5000 A

... switchgear assemblies are split into optimized shipping units with emphasis on ease of handling. Standard switchgear bays are usually shipped in one transport. All shipping units are mechanically and dielectrically tested before dispatch. In the case of modules that contain switching devices, all op ...
Ground Current Measurement
Ground Current Measurement

Series and Parallel Circuits
Series and Parallel Circuits

... When the switch is closed, the lamp lights up. This is because there is a continuous path of metal for the electric current to flow around. ...
BDTIC New NovalithIC™ BTN8982TA Integrated High Current Half-Bridge Motor Drivers
BDTIC New NovalithIC™ BTN8982TA Integrated High Current Half-Bridge Motor Drivers

... dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components ca ...
TD62083AFNG,TD62084AFNG - Toshiba America Electronic
TD62083AFNG,TD62084AFNG - Toshiba America Electronic

... in this document, and related hardware, software and systems (collectively “Product”) without notice. • This document and any information herein may not be reproduced without prior written permission from TOSHIBA. Even with TOSHIBA’s written permission, reproduction is permissible only if reproducti ...
TR41.9.2-03-05-016-R1-TransverseBalAltDraft
TR41.9.2-03-05-016-R1-TransverseBalAltDraft

E-96
E-96

... b. Find the power in the two intermediate settings. The two intermediate power levels are (using just one resistor) V2/16 = 900 W and V2/24 = 600 W 6. a. Find the Thevenin equivalent circuit for the circuit shown below. Show that VTh = 2100 V and RTh = 700 . ...
CIRCUIT FUNCTION AND BENEFITS
CIRCUIT FUNCTION AND BENEFITS

... (Continued from first page) "Circuits from the Lab" are intended only for use with Analog Devices products and are the intellectual property of Analog Devices or its licensors. While you may use the "Circuits from the Lab" in the design of your product, no other license is granted by implication or ...
Paper 3
Paper 3

... leakage flux does not vary ...
Fault Identification in a Radial Power System Using Fuzzy Logic
Fault Identification in a Radial Power System Using Fuzzy Logic

pract elec rev book - Deans Community High School
pract elec rev book - Deans Community High School

Quiz No.2 ECE 48
Quiz No.2 ECE 48

G028030
G028030

... connected to 1-Wire bus systems by means of sockets with contacts which touch the "lid" and "base" of the canister. iButtons are used as Akbil smart tickets for the Public transport in Istanbul. Alternatively, the connection can be semi-permanent with a different socket type; the iButton clips into ...
ORIGINATION FORM Proposed Revisions to the Specifications
ORIGINATION FORM Proposed Revisions to the Specifications

... SUBARTICLE 620-2.7.1 is deleted and the following substituted: 620-2.7.1 SPD for 120 Volt or 120/240 Volt Power: Install a SPD at the utility disconnect to the cabinet. Ensure that the SPD at the utility disconnect includes L-N, L-G, and N-G protection and has a maximum surge current rating of 50 kA ...
Electric Power Distribution
Electric Power Distribution

ELECTROMAGNETISM
ELECTROMAGNETISM

... People had tried similar experiments before, but only with static electricity, not with a moving electric current. For instance, they had hung batteries so that they were free to rotate in the earth's magnetic field, and found no effect; since the battery was not connected to a complete circuit, the ...
D12E12Safety1\4Curr\emet
D12E12Safety1\4Curr\emet

... 7.6.18 Explain the principle of the most common over current relays 7.6.19 Explain difference between the largest possible overload current and a fault current 7.6.20 Describe the function of the overcurrent trip, time delays and fuses with both overload and fault currents 7.6.21 Explain the basis u ...
GENERATORS- Honda Safety
GENERATORS- Honda Safety

Veris H600 - RSD Total Control
Veris H600 - RSD Total Control

E951 POWER SUPPLY
E951 POWER SUPPLY

ELECTRICAL Engineering Interview Questions With
ELECTRICAL Engineering Interview Questions With

Parallel Circuits
Parallel Circuits

... So the more resistors you add in parallel the lower the equivalent resistance will be. And because Req  the I  sometimes to a potentially dangerous level. This is why we have circuit breakers or fuses inserted into the main line of our homes. When we are trying to use too many electrical devices ( ...
summary of requirements
summary of requirements

... Terminations for flexible internal conductors: Where flexible conductors, including welding cable, flexible machine tool wires, and DLO cables, are provided, terminals at both ends of the conductor must be suitable for use with the conductor class. Manufacturers using flexible conductors after the e ...
< 1 ... 246 247 248 249 250 251 252 253 254 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report