• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Generator protection and control REG630 Flexibility for
Generator protection and control REG630 Flexibility for

Digital Micro-Ohm Meter
Digital Micro-Ohm Meter

See data sheet No. 2160
See data sheet No. 2160

... Protective Device (SPD) for Ethernet cable systems with RJ connectors is easy to install in new, or retrofitting into existing, installations. The BSPD48RJ45 is installed between the patch panel and the active component (a switch for example). The snap-in mechanism of the supporting foot allows the ...
Earth Ground Resistance
Earth Ground Resistance

... resistance of all ground paths will be extremely low as compared to any single path (the one under test). So, the net resistance of all the parallel return path resistances is effectively zero. If the ground system is not parallel to earth then you will either have an open circuit, or be measuring g ...
Lightning and Power Surges
Lightning and Power Surges

... • Install a lightning protection system – e.g., lightning rods (air terminals), down conductors, and grounding rods – on vulnerable structures and buildings. This will allow electrical current from lightning to travel safely to the ground. • Install transient voltage surge suppressors at the main ...
Comprehensive Modulation and Classification of Faults and
Comprehensive Modulation and Classification of Faults and

... failures, thus before starting supervisory system and fault diagnosis methods, it is necessary to identify what kind of failures can be found in the real system. The first step in this challenge is to cognition and classification all possible faults, in the first. On the other hand, the fault detect ...
TR41.9.2-05-02-007 - Telecommunications Industry Association
TR41.9.2-05-02-007 - Telecommunications Industry Association

PDF: 94KB
PDF: 94KB

... 4) . If the tweezers you use are possibly to touch the device terminals, use anti-static tweezers and in particular avoid metallic tweezers. If the device touches low resistance materials, rapid discharge can occur, and then the device can be degraded or destroyed. 5) Do not place the devices or the ...
Switch Yard Training Report NTPC Barh
Switch Yard Training Report NTPC Barh

Electrical safety for entertainers
Electrical safety for entertainers

Electrical Engineering
Electrical Engineering

... During the operation of the transformer, insulation inside deteriorates. When the gradual aging gets more severe, arcing discharge or incipient fault may occur. This may cause a short circuit between the adjacent turns of primary or secondary winding leading to a catastrophic failure. This catastrop ...
Lab 2
Lab 2

What is the current in the circuit?
What is the current in the circuit?

Printed-Circuit-Board Layout for Improved
Printed-Circuit-Board Layout for Improved

... The current peaks mentioned previously are one of the most significant causes of electromagnetic interference. Every time an output is switched, a corresponding pulse of current flows along the supply lines. The latter connections lead by a more or less direct route from the module to the central po ...
Model 548 Solid State DC Load Switch
Model 548 Solid State DC Load Switch

Flyer - Engineers Australia
Flyer - Engineers Australia

What is Cathodic Protection
What is Cathodic Protection

... Cathodic Protection (CP) is a technique to control the corrosion of a metal surface by making that surface the cathode of an electrochemical cell. In practical terms, CP is a method used to protect metal structures from corrosion. Cathodic protection systems are most commonly used to protect steel w ...
2BOhmsLaw - WordPress.com
2BOhmsLaw - WordPress.com

Computer Activity Questions
Computer Activity Questions

Theory of Alternating Currents
Theory of Alternating Currents

EVALUATION AND DESIGN SUPPORT
EVALUATION AND DESIGN SUPPORT

... The pin-selectable switching frequency and PWM current mode architecture allows easy noise filtering and yields excellent transient response. The components connected around the ADP1613 generate a 32 V output from a 3 V input. ...
Technical Note: Installation and Grounding of Magmeters
Technical Note: Installation and Grounding of Magmeters

Define - UniMAP Portal
Define - UniMAP Portal

... two standard circuits are: 1. 20 A fuse or miniature circuit breaker protection with 2.5 mm² live and 1.5mm² protective conductors (or 1.5 mm² if m.i. cable) feeding a floor area of not more than 50 m². If the circuit feeds a kitchen or utility room, it must be remembered that a 3 kW device such as ...
Feeder Protection - 123SeminarsOnly.com
Feeder Protection - 123SeminarsOnly.com

2SB1198K : Transistors
2SB1198K : Transistors

... The products listed in this document are designed to be used with ordinary electronic equipment or devices (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devic ...
< 1 ... 248 249 250 251 252 253 254 255 256 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.