• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
TB#098 PPE and Arc Resistant Switchgear
TB#098 PPE and Arc Resistant Switchgear

PDS-E Series Step/Direction Drives
PDS-E Series Step/Direction Drives

SMS05C through SMS24C
SMS05C through SMS24C

Dual impedance digital multimeters
Dual impedance digital multimeters

ABSTRACT - 123SeminarsOnly.com
ABSTRACT - 123SeminarsOnly.com

UPEC 2010 - Preparation of Papers in Two
UPEC 2010 - Preparation of Papers in Two

... This is caused by the interaction of different circumstances; for short circuits near “Sexau” substation the voltage at “Sexau” substation is almost zero, the same as in the case without integration of DG units. Because of that the same short circuit current is delivered by the feeder. Added to this ...
EMC filters 2-line filters SIFI-C for very high
EMC filters 2-line filters SIFI-C for very high

... As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specifi ...
STEVAL-ILL017V1
STEVAL-ILL017V1

... VDC source, suitable for illuminating two LEDs in series. The VIPer17 device is an offline converter with an 800 V rugged power section, a PWM control, overcurrent protection, overvoltage and overload protection, hysteretic thermal protection, soft-start and safe auto-restart after the removal of a ...
External Disconnect Switches - Infiltrator Water Technologies
External Disconnect Switches - Infiltrator Water Technologies

... to protect the electrical circuits from damage caused by power overloads or power short circuits. They are not designed to protect system components against lightning events or voltage surges. Due to the short length of this type of event, a fuse or varistor are better designed for this application. ...
presentation on symmetrical componenets of power system
presentation on symmetrical componenets of power system

... REFERENCES ...
three phase transformers three phase system basics
three phase transformers three phase system basics

High Current Test Sets - agea
High Current Test Sets - agea

Kit 47. 6-10 Watt Monophonic Power Amplifier
Kit 47. 6-10 Watt Monophonic Power Amplifier

... differential input. R2 and R3 set the level of feed back. C4 and R4 provide a high frequency load for stability where loudspeaker inductive reactance may become excessive. C5 and C6 provide power supply decoupling or filtering. We have increased C3 from 1000uF (1mF) to 2200uF so if you have a PCB ma ...
AC_Circuits1
AC_Circuits1

... capacitor becomes positively charged and plate Y negatively charged. During the negative half-cycle, X receives a negative charge and Y a positive one. There is therefore an alternating flow of charge or alternating current, i, through the capacitor Thus, unlike the case for a dc voltage where the c ...
eet 3086 switchgear and protection
eet 3086 switchgear and protection

... differential protection system, which superficially, cannot be distinguished from a current unbalance caused by a fault in the transformer. When magnetizing inrush is severe, the current unbalance may easily exceed the current required to trip the differential relay and cause undesired disconnection ...
Protection components - Elektronický katalog Schneider Electric
Protection components - Elektronický katalog Schneider Electric

MS Word
MS Word

... Fortunately for us, the resistance of dry skin is a very important protection at low voltages. Typically, over an ordinary contact area, the skin inserts 10 100 k between an outside conductor (like the end of a banana lead or multimeter probe) and the internal body fluids. Therefore, at voltages be ...
B . A = BA - RAJEEV Classes
B . A = BA - RAJEEV Classes

Document
Document

... the current, the capacitance and the inductance. (Assume no energy loss in both cases.) (iii) Explain why it would be difficult to sustain such an electromagnetic oscillation in practice. With the aid of a graph, describe how the current in the circuit actually varies with time. (10 marks) (c) When ...
AC Power Switch
AC Power Switch

... Digitally Programmable Solid State Power Controller - Demonstrator The Digitally Programmable Solid State Power Controller was developed as a base for a power management and distribution system to meet the needs of future and existing platforms requirements for safe circuit protection devices on ai ...
underground cable fault distance locator
underground cable fault distance locator

Comments on 802.3-2012 - IEEE Standard for Ethernet
Comments on 802.3-2012 - IEEE Standard for Ethernet

... SELV circuit [b-IEC 60950-1]: secondary circuit that is so designed and protected that under normal operating conditions and single fault conditions, its voltages do not exceed a safe value TNV circuit [b-IEC 60950-1]: circuit that is in the equipment and to which the accessible area of contact is l ...
S4624 npmxxx Reactive Power
S4624 npmxxx Reactive Power

... In a predominantly capacitive circuit an electrical charge is maintained in the circuit. A similar effect occurs to that in an inductive circuit but now the current waveform leads the voltage waveform as the voltage is subject to the inertia created by the electrical charge in the circuit. If the c ...
���������������� ������ - Noor Technology for General Trading, Contracting
���������������� ������ - Noor Technology for General Trading, Contracting

RPI-352
RPI-352

... The products listed in this document are designed to be used with ordinary electronic equipment or devices (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devic ...
< 1 ... 235 236 237 238 239 240 241 242 243 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report