• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Electrostatic motor
Electrostatic motor

... spark gaps to sub-mm precision. This is particularly important for operating voltages below 10kV. To keep it safe, cheap and simple I suggest using a negative-ion generator power module as a HV source. These are available for around $10, sometimes less, and produce up to about 10kV negative voltage ...
HACR Ratings and UL® Listed Molded Case Circuit
HACR Ratings and UL® Listed Molded Case Circuit

... 600 Vac and less and 250 A maximum as a second step. By these test parameters HACR Type circuit breakers were the same as other types of inverse-time circuit breakers except they were additionally investigated by UL and determined to be suitable for motor branch circuit protection on group installat ...
Transformers
Transformers

20151112 SOTWG Item 08c TOP-09 R1 Tasks
20151112 SOTWG Item 08c TOP-09 R1 Tasks

Atomic Structure - BDJ Engineering
Atomic Structure - BDJ Engineering

... Resistance Resistance: The opposition to the flow of current. ...
Document
Document

... identify problems in building power distribution systems without making physical contact with the equipment to be tested. ...
Variable Dimming - 100-277VAC
Variable Dimming - 100-277VAC

Slide 1
Slide 1

... Output (6) ...
ICL7673 Datasheet
ICL7673 Datasheet

... open-drain N-Channel transistor PBAR . The first inverter drives a large P-Channel switch, P1, a second inverter, and another open-drain N-Channel transistor, SBAR . The second inverter drives another large P-Channel switch P2. The ICL7673, connected to a main and a backup power supply, will connect ...
All Mode Instructions.pmd
All Mode Instructions.pmd

2 single phase transformers - Arrdekta Institute of Technology
2 single phase transformers - Arrdekta Institute of Technology

...  neutral in secondary can be grounded for 3 phase 4 wire system.  Neutral shifting and 3rd harmonics are there.  Phase shift of 30⁰ between secondary and primary currents and voltages. ...
Generators and Transformers
Generators and Transformers

Chapter 24: Capacitance and Dielectrics and Ch. 26
Chapter 24: Capacitance and Dielectrics and Ch. 26

Building a Headphone Amplifier
Building a Headphone Amplifier

... Typical Altoids tins are slightly larger. Most builders will appreciate the extra room. ...
OHM`S LAW LAB
OHM`S LAW LAB

... series circuit, and RC series circuit, were AC circuits. In both cases, the concept of reactance was investigated. The results showed that the reactive component had its own voltage drop that was out of phase with the resistive component, although the circuit current was the same in all parts of the ...
10EE751 HVDC TRANSMISSION
10EE751 HVDC TRANSMISSION

BSNL_TTA_Electricalspecialization
BSNL_TTA_Electricalspecialization

SECTION (ELECTRICAL) 1. In a D.C. generator, if the brushes are
SECTION (ELECTRICAL) 1. In a D.C. generator, if the brushes are

... 6. Leakage fluxes of transformer may be minimized by a. Reducing the magnetizing current to the minimum b. Reducing the reluctance of the iron core to the minimum c. Reducing the number of primary and secondary turn to the minimum d. Sectionalizing and interleaving the primary and secondary windings ...
BP-320 Technical Data Package
BP-320 Technical Data Package

Electric Circuits
Electric Circuits

... HS-PS2-5. Plan and conduct an investigation to provide evidence that an electric current can produce a magnetic field and that a changing magnetic field can produce an electric current. HS-PS2-6. Communicate scientific and technical information about why the molecular-level structure is important in ...
Physical Principles of Defibrillators
Physical Principles of Defibrillators

... International Electrotechnical Committee (IEC) symbols for ‘defibrillator safe’ equipment ...
Module 1 : Fundamentals of Power System Protection Lecture 3
Module 1 : Fundamentals of Power System Protection Lecture 3

Experiment FT2: Measurement of Inductance and Mutual Inductance
Experiment FT2: Measurement of Inductance and Mutual Inductance

TAINY GMOD-S3
TAINY GMOD-S3

... DC. The output of the external power supply must be protected against short circuiting. When connecting to a battery or an accumulator, please ensure that there is likewise an all-phase separator (battery master switch) and a fuse with sufficient separating ability between the device and the battery ...
投影片 1
投影片 1

... sequence. (b) The acb (negative) sequence. ...
< 1 ... 236 237 238 239 240 241 242 243 244 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report