• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Typical Current Transformer
Typical Current Transformer

QUASAR KIT No. 1209: ±40V, 8A Dual Polarity Power Supply
QUASAR KIT No. 1209: ±40V, 8A Dual Polarity Power Supply

Dual-Color Chip LEDs with Reflector 1210 3.0 2.5 t=1.3mm
Dual-Color Chip LEDs with Reflector 1210 3.0 2.5 t=1.3mm

Network Theorems
Network Theorems

SML-020MLTT86 - ROHM Co., Ltd.
SML-020MLTT86 - ROHM Co., Ltd.

OET 001 DC Circuits TAG Rubric EET Define/Explain: Schematic
OET 001 DC Circuits TAG Rubric EET Define/Explain: Schematic

... The purpose of this guide is to provide a range of knowledge at which students can demonstrate proficiency for each objective. Subsequent college course success depends strongly on courses taught primarily at the “some applied skills present” and “applied skills strongly demonstrated” levels. ...
Bio-impedance Measurement
Bio-impedance Measurement

Performing Isolation Tests on High Voltage Power Supplies
Performing Isolation Tests on High Voltage Power Supplies

Producing Electric Current - District 273 Technology Services
Producing Electric Current - District 273 Technology Services

... Direct and Alternating Currents  Compare and contrast current in batteries and generators:  Compare: Both devices move electrons through the wire  Contrast: Batteries have DC. Generators have AC. ...
Download PGR-6130 Datasheet
Download PGR-6130 Datasheet

... protective functions include overload, overtemperature, phase unbalance, phase loss, and phase sequence. The PGR-6130 Electronic Overload Relay offers dependable protection and can be used on pumps, conveyor belts, ventilation fans and other small-motor applications that require standard protection. ...
EES612-Lab-1 Single - Department of Electrical and Computer
EES612-Lab-1 Single - Department of Electrical and Computer

... flux in turn produces the hysteresis loss and the eddy current loss in the core. These two losses are collectively called the core loss, P c ore . In this experiment, the core losses of a transformer are evaluated through the opencircuit test at the rated voltage, whereas the copper losses are measu ...
GK-12 Breadboard Tips and Techniques for Digital Circuit
GK-12 Breadboard Tips and Techniques for Digital Circuit

I56-3326 MIX-M502MAPA
I56-3326 MIX-M502MAPA

... The MIX-M502MAPA Interface Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary decade switches. This module allows intelligent panels to interface and monitor two-wire conventional smoke detectors. It transmit ...
TB6612FNG
TB6612FNG

3.4 Three-phase transformer (pole-mounted
3.4 Three-phase transformer (pole-mounted

...  If the LV conductors are energised from an interconnected transformer, conduct the phase-out test at the new transformer’s LV disconnector or fuse box.  If the LV conductors are not energised, proceed to item 5 (ENERGISATION OF THE NETWORK WITH LOAD) and conduct the phase-out test on normally ope ...
Capacitor Self
Capacitor Self

Welding Machines/Electricity
Welding Machines/Electricity

... second to complete a cycle or hertz. – The frequency is indicated as 25, 40, 50, and 60 cycles per second. ...
Retrofit for Safety
Retrofit for Safety

... ahead of the device being controlled. If power to the facility is lost, the devices can still be opened manually. There is no arc flash hazard present in this case since the equipment is not energized. Another solution to mitigate arc flash for consideration by the consultant and owner is a maintena ...
current fuction usage for current lines construction in 2d models
current fuction usage for current lines construction in 2d models

... current electrodes, where the electrical field always is three-dimensional. Meanwhile the actual results of such modeling are qualitatively equivalent to 3D modeling with point electrodes, as long as the measurements are conducted across the objects. The classical modeling presentation is in apparen ...
PS22A76
PS22A76

... 4 :R1, C4 of RC filter for preventing protection circuit malfunction is recommended to select tight tolerance, temp-compensated type. The time constant R1C4 should be set so that SC current is shut down within 2μs. (1.5μs~2μs is general value.) SC interrupting time might vary with the wiring pattern ...
Electrical Safety
Electrical Safety

... equipment, or parts under energized lines unless: ◦ Employee is wearing the proper electrical PPE; or ◦ Equipment/vehicle is located so that no uninsulated part can provide a conductive path to employees ...
KD2003-CF30A
KD2003-CF30A

... KD2003-CF30A is suitable for devices, such as high-speed POS and label printer applications, that require thermal printheads capable of higher printing rates. Improved power circuit design means that with heavier current it is possible to print at speeds as high as 150 mm/s. The GK Series is the thu ...
Electricity scheme
Electricity scheme

... Graph data for various voltages (water temp vs voltage). The higher the voltage the greater the electrical energy, so higher temp.. ...
Ohmic devices - marineabudhabi
Ohmic devices - marineabudhabi

... 3rd CALL: Call for the teacher before using the ohmmeter. E8. With the ohmmeter, measure the resistance of resistors 1 and 2. R1 = ………….. R2 = ………….. Q9. Compare your measurements with the characteristics obtained at question I.2.b. What do you notice? Q10. Write a general relation that links the re ...
IEEE Generator Protection - Levine Lectronics and Lectric
IEEE Generator Protection - Levine Lectronics and Lectric

< 1 ... 209 210 211 212 213 214 215 216 217 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report