• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
High Speed Digital Video
High Speed Digital Video

... ground. During a positive voltage transient the top diode will conduct the surge current (I1) into the power rail. Dumping the surge current into an unprotected supply rail can cause latch up of the protection circuit, so an additional transient voltage suppression (TVS) device between the supply ra ...
Transpower Planning criteria
Transpower Planning criteria

MSC8122 and MSC8126 Power Circuit Design Recommendations
MSC8122 and MSC8126 Power Circuit Design Recommendations

... As the supply voltage rises, base current drawn through resistor R1 turns transistor T1 off. Current from the 3.3 V supply moves to the core VDD rail and charges the on-board decoupling capacitors. When the voltage on the core VDD rail rises to ~0.8 V, current begins to pass through R2 and D1 to the ...
Electricity - School
Electricity - School

Lab 1 - La Salle University
Lab 1 - La Salle University

Document
Document

section 16920-1 - OPS Schneider Electric
section 16920-1 - OPS Schneider Electric

... (CTs) to measure current on each circuit in a power distribution unit (PDU). b) The BCPM shall also include inputs for 1/3 V AC CTs to allow measurement of the current on the incoming mains. In addition, the BCPM shall include inputs to allow measurement of the voltage of the incoming mains. c) The ...
PPT
PPT

FUNDAMENTALS OF CALCULATION OF EARTH POTENTIAL RISE
FUNDAMENTALS OF CALCULATION OF EARTH POTENTIAL RISE

Lecture 4 - Power System Protection
Lecture 4 - Power System Protection

Relocatable Power Taps “RPT`s”
Relocatable Power Taps “RPT`s”

TEACHING PLAN - UniMAP Portal
TEACHING PLAN - UniMAP Portal

Lecture 4 - Power System Protection
Lecture 4 - Power System Protection

Transient Voltage Surge Suppression and
Transient Voltage Surge Suppression and

BUF634 250-mA High-Speed Buffer (Rev. A)
BUF634 250-mA High-Speed Buffer (Rev. A)

... The BUF634 device is a high speed, unity-gain open-loop buffer recommended for a wide range of applications. The BUF634 device can be used inside the feedback loop of op amps to increase output current, eliminate thermal feedback, and improve capacitive load drive. For low power applications, the BU ...
Analysis of the Occurrence of a Three-Phase Short-Circuit
Analysis of the Occurrence of a Three-Phase Short-Circuit

... for the transmission line three-phase short -circuit was possible utilizing CEMIG Lightning Location System (SLT) technology. This system combines information from the Fault Locator and Analysis System (FALLS) with the transmission line routes digitized and converted into a geoprocessing platform us ...
Electrical Services Audit - Gold Coast Hospital
Electrical Services Audit - Gold Coast Hospital

... Each panel is connected to a separate RCD, however all RCDs are on the one circuit. No UPS power or line isolation monitored power is available. This arrangement is not considered acceptable. Staff advised that on at least one occasion the single circuit to a theatre overloaded and required an elect ...
Ground Resistance Clamp-On Tester - Cole
Ground Resistance Clamp-On Tester - Cole

Lab 6: Electric Circuits Essentials of Physics: PHYS 101
Lab 6: Electric Circuits Essentials of Physics: PHYS 101

30104 Operate electrical switchgear in the electricity
30104 Operate electrical switchgear in the electricity

... specifications; and enterprise requirements which cover the documented workplace policies, procedures, specifications, business, and quality management requirements relevant to the workplace in which assessment is carried out. Status refers to the operational condition or state of any or all of the ...
SECTION 264313 SURGE PROTECTIVE DEVICES 03/03/14
SECTION 264313 SURGE PROTECTIVE DEVICES 03/03/14

... 2.2 SURGE PROTECTIVE DEVICE ................................................................................................... 4 ...
Current Integrators
Current Integrators

... An array of dosimeters (IC’s or diodes) requires an array of integrators, and that can be more challenging and expensive than the detector itself. There are two kinds of integrators: classical and recycling. Both can be used either singly or in arrays, using either discrete integrated circuits or AS ...
Chapter-10: Design Of Ehvand UHV Sub-Station
Chapter-10: Design Of Ehvand UHV Sub-Station

Single Electron Tunneling Junctions
Single Electron Tunneling Junctions

... To get a feeling for the behavior of an isolated SETJ, let’s first turn off the pump voltage. The behavior then resembles a relaxation oscillator. ...
AAT4614 数据资料DataSheet下载
AAT4614 数据资料DataSheet下载

... The AAT4614 operates with input voltages ranging from 2.4V to 5.5V which, along with its extremely low operating current, makes it ideal for battery-powered applications. In cases where the input voltage drops below 2.4V, the AAT4614 MOSFET is protected from entering the saturated region of operatio ...
< 1 ... 120 121 122 123 124 125 126 127 128 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report