• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
S.T.A.R. PATHFINDER variable trip test point faulted circuit indicators
S.T.A.R. PATHFINDER variable trip test point faulted circuit indicators

Single-Line Diagrams
Single-Line Diagrams

Technical Guidelines and Requirements for Parallel
Technical Guidelines and Requirements for Parallel

Trame Rapport
Trame Rapport

Choose a Regulator with an Accurate Input Current Limit to Safely
Choose a Regulator with an Accurate Input Current Limit to Safely

31-00028—01 - Sylk™ I/O Devices
31-00028—01 - Sylk™ I/O Devices

Solution
Solution

... Solution: Two cases must be described as follow Case#1: Rs1=Rs2=R=80 kΩ ...
Electricity Distribution Network
Electricity Distribution Network

4316C-part2
4316C-part2

... 5.1.29 fault-tolerant — designed so that a reasonably foreseeable single point failure does not result in an unsafe condition. 5.1.30 ground fault — an unintentional, electrically conducting connection between an ungrounded or grounded conductor of an electrical circuit and the normally non-current- ...
Parallel Resonance - KFUPM Resources v3
Parallel Resonance - KFUPM Resources v3

Augmentation Protection
Augmentation Protection

...  All circuit breaker backup and dead zone trips must be independently initiated by X and Y primary protection.  Protection times specified apply to both X and Y protection schemes.  All fault clearance times, including backup/dead zone protection, include circuit breaker operating times, includin ...
Transformer Basics Information Guide
Transformer Basics Information Guide

... A transformer that is fed, on the primary windings, by three equal alternating voltages, the timing of which are 120 degrees “out of phase” with each other. A typical application would be 480V input with 120/208V output, where the grounded conductor (neutral) on the 120V output is common with all th ...
Transformer
Transformer

- National Grid
- National Grid

Distribution Systems
Distribution Systems

... latter case, manholes, duct lines etc., are permanently placed once installed and the load expansion can only be met by laying new lines. However, on an overhead system, poles, wires, transformers etc., can be easily shifted to meet the changes in load conditions. (iv) Faults. The chances of faults ...
Transformer Polarity
Transformer Polarity

... Current Transformers (CT’s) are used to supply a proportional current to the current input of metering and relaying equipment. The standard CT secondary current is 5 amps to match the standard full-scale current rating of switchboard indicating devices, power metering equipment, and protective relay ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... transformers are installed along the streets and roads sides paving way for easy connection of consumers‟ service mains from the Distribution lines emanating from the Distribution Transformer via overhead lines. According to (Wikipedia,2013) “A distribution transformer is a transformer that provides ...
Golden, R. M. (2000). Kirchoff law Markov fields for analog circuit design. In S. A. Solla, T. K. Leen, and K. R. Muller (eds.) Neural Information Processing Systems Proceedings, 12, MIT Press, Cambridge, 907-913.
Golden, R. M. (2000). Kirchoff law Markov fields for analog circuit design. In S. A. Solla, T. K. Leen, and K. R. Muller (eds.) Neural Information Processing Systems Proceedings, 12, MIT Press, Cambridge, 907-913.

... Thus, ki = 10 in this example. By limiting the choice of C I4 to a small number of finite values, this permits the introduction of design expertise hints directly into the problem formulation without making strong committments to the ultimate choice of the value of capacitor C 14 • Other examples of ...
MEDIUM-VOLTAGE SWITCHGEAR
MEDIUM-VOLTAGE SWITCHGEAR

... B. The circuit breakers shall have connected, test and disconnected indicators and open, closed, ready to close indicators which shall be visible to the operator with compartment door closed. It shall be able to rack the breaker with the compartment door closed. C. Interlocks shall be provided to pr ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... differential data mode to be accessed, and the small voltage swings that are present can be more accurately detected. Access to the SRAM memory cell is enabled by the Word Line. This controls the two access control transistors which control whether the cell should be connected to the bit lines. Thes ...
TR41.9.2-04-05-012-MR1-OPS-voltage
TR41.9.2-04-05-012-MR1-OPS-voltage

Sepam 2000 - Schneider Electric
Sepam 2000 - Schneider Electric

MAX3188E/MAX3189E ±15kV ESD-Protected, 1Mbps, 1µA RS-232 Transmitters in SOT23-6 General Description
MAX3188E/MAX3189E ±15kV ESD-Protected, 1Mbps, 1µA RS-232 Transmitters in SOT23-6 General Description

... supply current from ±4.5V to ±6V supplies. They feature a shutdown input that reduces current consumption to only 1µA and forces the transmitter output into a high-impedance state. RS-232 data transmission is guaranteed up to 250kbps with the MAX3188E and up to 1Mbps with the MAX3189E. The MAX3188E/ ...
balanced three–phase circuits
balanced three–phase circuits

... : internal impedance of each phase in generator : line impedance ...
MTI TN113: The Series to Parallel Impedance Transformation
MTI TN113: The Series to Parallel Impedance Transformation

< 1 ... 116 117 118 119 120 121 122 123 124 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report