• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
fault zone analysis
fault zone analysis

MC33887, 5.0 A H-Bridge with Load Current Feedback
MC33887, 5.0 A H-Bridge with Load Current Feedback

MAX256 3W Primary-Side Transformer H-Bridge Driver for Isolated Supplies General Description
MAX256 3W Primary-Side Transformer H-Bridge Driver for Isolated Supplies General Description

... maximum input voltage and low output load current, the voltage at the output of the rectifier network can exceed the absolute maximum input voltage of the low dropout regulator (LDO). If the minimum output load current is less than approximately 5mA, connect a zener diode from the output voltage to ...
datasheet - Intersil
datasheet - Intersil

... The ISL69134 is a digital dual output, flexible multiphase (X+Y ≤ 4) PWM controller designed to be compliant with Intel IMVP8 specifications. The digital multiphase controller can be configured to support any desired phase assignments up to a maximum of 4 phases across the two outputs (X and Y). For ...
magnetizing current effect minimization in current transformers
magnetizing current effect minimization in current transformers

... U2 – voltage drop on R1 resistor caused by i2 secondary current flow, U0 – voltage drop on R2 resistor caused by io magnetizing current flow. Magnetizing current io influence is being eliminated in the output which in effect gives very precise result of the transformation. In effect i1 current is eq ...
Series 440 Installation and Operation Instructions
Series 440 Installation and Operation Instructions

... Please take note when installing the head transmitter remotely in a field housing. The screen on the (4 to 20) mA signal output must have the same potential as the screen at the sensor connections. When using earthed thermocouples, screening of the output (4 to 20) mA cable is recommended. In plants ...
MAX1558/MAX1558H Dual, 3mm x 3mm, 1.2A/Programmable-Current USB Switches with Autoreset General Description
MAX1558/MAX1558H Dual, 3mm x 3mm, 1.2A/Programmable-Current USB Switches with Autoreset General Description

... condition, which reduces system load current and power dissipation. If a short circuit persists for 20ms, the output turns off and the fault flag is set. The autoreset circuit automatically restarts the part if the fault is removed. ...
IQ131+ Controller Data Sheet - wind
IQ131+ Controller Data Sheet - wind

TRANSIENT PROTECTION SOLUTIONS: Transil™ diode versus
TRANSIENT PROTECTION SOLUTIONS: Transil™ diode versus

Form Factors and Power Supplies
Form Factors and Power Supplies

... Form factor: specifies size, shape, features of device Motherboard, power supply, and case share the same form factor, such as ATX Three types of cases: desktop, tower, and notebook Quantities that characterize electricity: voltage, current, resistance, and power Current flows from hot wires to neut ...
Physical Science: Unit 8: Sound
Physical Science: Unit 8: Sound

Powercut 900
Powercut 900

Electrical Design Team Guidance Notes GN31 Pedestrian
Electrical Design Team Guidance Notes GN31 Pedestrian

Operating instructions R4D630RB1501 - ebm
Operating instructions R4D630RB1501 - ebm

Fault Detection in Induction Machine by Application
Fault Detection in Induction Machine by Application

... proper functioning, the safety and security of goods and devices. To do this, the industrial and scientific communities are seeking solutions to make these systems more competitive, more efficient, and safer. One of the routes on which research works is oriented is the conditional preventive mainten ...
Drain current injection circuitry for enabling the use of super
Drain current injection circuitry for enabling the use of super

... Stage 5: S1 turns on during this phase and IDa and IDb are driven to zero. With respect to Fig. 8, it is noted that S1 only supplies a very small charging current of approximately 7-8A peak into S2’s output capacitance as the bulk of the required charge has been supplied by the DCI circuit. The inje ...
ACS713 - Allegro Microsystems
ACS713 - Allegro Microsystems

... solutions for DC current sensing in industrial, commercial, and communications systems. The device package allows for easy implementation by the customer. Typical applications include motor control, load detection and management, switch-mode power supplies, and overcurrent fault protection. The devi ...
Investigation of Polarization and Depolarization Current for
Investigation of Polarization and Depolarization Current for

Data Sheet - technicalaudio.com
Data Sheet - technicalaudio.com

Analysis of Low-Frequency Electromagnetic Devices using Finite
Analysis of Low-Frequency Electromagnetic Devices using Finite

Installation Instruction Sheet for Vision Site Small LED
Installation Instruction Sheet for Vision Site Small LED

... IMPORTANT: READ BEFORE REMOVING FIXTURE FROM CARTON. RETAIN FOR FUTURE REFERENCE. SAFETY: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedur ...
Small Current Output Power Management Switch ICs
Small Current Output Power Management Switch ICs

Raychem Testing Locating Faults Engineering Specifications
Raychem Testing Locating Faults Engineering Specifications

... They require an external 6-volt lantern battery as a separate voltage source. A potentiometer calibrated in percent permits the bridge to be balanced and the distance to the fault, from the negative end, is read as a percent of the actual cable length, L. Refer to the operation manual for complete d ...
SCI 111
SCI 111

S.T.A.R. PATHFINDER variable trip test point faulted circuit indicators
S.T.A.R. PATHFINDER variable trip test point faulted circuit indicators

< 1 ... 115 116 117 118 119 120 121 122 123 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report