MAX256 3W Primary-Side Transformer H-Bridge Driver for Isolated Supplies General Description
... maximum input voltage and low output load current, the voltage at the output of the rectifier network can exceed the absolute maximum input voltage of the low dropout regulator (LDO). If the minimum output load current is less than approximately 5mA, connect a zener diode from the output voltage to ...
... maximum input voltage and low output load current, the voltage at the output of the rectifier network can exceed the absolute maximum input voltage of the low dropout regulator (LDO). If the minimum output load current is less than approximately 5mA, connect a zener diode from the output voltage to ...
datasheet - Intersil
... The ISL69134 is a digital dual output, flexible multiphase (X+Y ≤ 4) PWM controller designed to be compliant with Intel IMVP8 specifications. The digital multiphase controller can be configured to support any desired phase assignments up to a maximum of 4 phases across the two outputs (X and Y). For ...
... The ISL69134 is a digital dual output, flexible multiphase (X+Y ≤ 4) PWM controller designed to be compliant with Intel IMVP8 specifications. The digital multiphase controller can be configured to support any desired phase assignments up to a maximum of 4 phases across the two outputs (X and Y). For ...
magnetizing current effect minimization in current transformers
... U2 – voltage drop on R1 resistor caused by i2 secondary current flow, U0 – voltage drop on R2 resistor caused by io magnetizing current flow. Magnetizing current io influence is being eliminated in the output which in effect gives very precise result of the transformation. In effect i1 current is eq ...
... U2 – voltage drop on R1 resistor caused by i2 secondary current flow, U0 – voltage drop on R2 resistor caused by io magnetizing current flow. Magnetizing current io influence is being eliminated in the output which in effect gives very precise result of the transformation. In effect i1 current is eq ...
Series 440 Installation and Operation Instructions
... Please take note when installing the head transmitter remotely in a field housing. The screen on the (4 to 20) mA signal output must have the same potential as the screen at the sensor connections. When using earthed thermocouples, screening of the output (4 to 20) mA cable is recommended. In plants ...
... Please take note when installing the head transmitter remotely in a field housing. The screen on the (4 to 20) mA signal output must have the same potential as the screen at the sensor connections. When using earthed thermocouples, screening of the output (4 to 20) mA cable is recommended. In plants ...
MAX1558/MAX1558H Dual, 3mm x 3mm, 1.2A/Programmable-Current USB Switches with Autoreset General Description
... condition, which reduces system load current and power dissipation. If a short circuit persists for 20ms, the output turns off and the fault flag is set. The autoreset circuit automatically restarts the part if the fault is removed. ...
... condition, which reduces system load current and power dissipation. If a short circuit persists for 20ms, the output turns off and the fault flag is set. The autoreset circuit automatically restarts the part if the fault is removed. ...
Form Factors and Power Supplies
... Form factor: specifies size, shape, features of device Motherboard, power supply, and case share the same form factor, such as ATX Three types of cases: desktop, tower, and notebook Quantities that characterize electricity: voltage, current, resistance, and power Current flows from hot wires to neut ...
... Form factor: specifies size, shape, features of device Motherboard, power supply, and case share the same form factor, such as ATX Three types of cases: desktop, tower, and notebook Quantities that characterize electricity: voltage, current, resistance, and power Current flows from hot wires to neut ...
Fault Detection in Induction Machine by Application
... proper functioning, the safety and security of goods and devices. To do this, the industrial and scientific communities are seeking solutions to make these systems more competitive, more efficient, and safer. One of the routes on which research works is oriented is the conditional preventive mainten ...
... proper functioning, the safety and security of goods and devices. To do this, the industrial and scientific communities are seeking solutions to make these systems more competitive, more efficient, and safer. One of the routes on which research works is oriented is the conditional preventive mainten ...
Drain current injection circuitry for enabling the use of super
... Stage 5: S1 turns on during this phase and IDa and IDb are driven to zero. With respect to Fig. 8, it is noted that S1 only supplies a very small charging current of approximately 7-8A peak into S2’s output capacitance as the bulk of the required charge has been supplied by the DCI circuit. The inje ...
... Stage 5: S1 turns on during this phase and IDa and IDb are driven to zero. With respect to Fig. 8, it is noted that S1 only supplies a very small charging current of approximately 7-8A peak into S2’s output capacitance as the bulk of the required charge has been supplied by the DCI circuit. The inje ...
ACS713 - Allegro Microsystems
... solutions for DC current sensing in industrial, commercial, and communications systems. The device package allows for easy implementation by the customer. Typical applications include motor control, load detection and management, switch-mode power supplies, and overcurrent fault protection. The devi ...
... solutions for DC current sensing in industrial, commercial, and communications systems. The device package allows for easy implementation by the customer. Typical applications include motor control, load detection and management, switch-mode power supplies, and overcurrent fault protection. The devi ...
Installation Instruction Sheet for Vision Site Small LED
... IMPORTANT: READ BEFORE REMOVING FIXTURE FROM CARTON. RETAIN FOR FUTURE REFERENCE. SAFETY: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedur ...
... IMPORTANT: READ BEFORE REMOVING FIXTURE FROM CARTON. RETAIN FOR FUTURE REFERENCE. SAFETY: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedur ...
Raychem Testing Locating Faults Engineering Specifications
... They require an external 6-volt lantern battery as a separate voltage source. A potentiometer calibrated in percent permits the bridge to be balanced and the distance to the fault, from the negative end, is read as a percent of the actual cable length, L. Refer to the operation manual for complete d ...
... They require an external 6-volt lantern battery as a separate voltage source. A potentiometer calibrated in percent permits the bridge to be balanced and the distance to the fault, from the negative end, is read as a percent of the actual cable length, L. Refer to the operation manual for complete d ...