• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Easy Electromagnet Handout (Teacher)
Easy Electromagnet Handout (Teacher)

Important Principle:
Important Principle:

MAX8533 Smallest, Most Reliable, 12V, Infiniband- Compliant Hot-Swap Controller General Description
MAX8533 Smallest, Most Reliable, 12V, Infiniband- Compliant Hot-Swap Controller General Description

... The MAX8533 is a single-port, 12V, InfinibandTM-compliant (IB) versatile hot-swap controller. The device can be implemented in both IB Class I (nonisolated) and Class II (isolated) power-topology applications. Additionally, the MAX8533 can be used as a reliable power controller on hot-swappable blad ...
EN / ACS800 Single Drive Common DC
EN / ACS800 Single Drive Common DC

... • Unequal current distribution is influenced by input cables, AC or DC chokes and input bridges’ forward characteristics. If the voltage reduction over the supply components mentioned is not the same with all converters, more current will flow through the converter which has a lower voltage reductio ...
electric phenomena in relation to lubrication .` of machines
electric phenomena in relation to lubrication .` of machines

... Another method of eliminating the effects of shaft "Electrolysis" regarding the Voltol process). currents is to fit earth brushes to connect the shaft As the average milli-volt meter will not necessarily with the bearing pedestal, thus shunting the oil film. show high-frequency A.C. currents, tests ...
P85452_003 - Ceiling
P85452_003 - Ceiling

... NOTE: For surface mounting options please use the LSPKBB-C accessory products. WARNING: DO NOT PAINT THIS DEVICE. WARNING: When installing strobes in an open office or other areas containing partitions or other viewing obstructions, special attention should be given to the location of the strobes so ...
Current Transducer CTSR 0.3-TP/SP14 I = 300 mA
Current Transducer CTSR 0.3-TP/SP14 I = 300 mA

Series/Parallel Bulb Board
Series/Parallel Bulb Board

... electrical energy is being distributed due to a particular hookup. By using electrical meters, it is possible to make quantitative measurements of the distribution of energy, but such measurements are only recommended for advanced students (see below). Set-up Instructions: The suggested bulbs to be ...
RC circuit
RC circuit

... • The natural response of a circuit refers to the behavior (in terms of voltages and currents) of the circuit itself, with no external sources of excitation. Time constant ...
BS 7671:2008 forms
BS 7671:2008 forms

... earth electrode ...
Digital Low-Impedance Bus Differential Protection
Digital Low-Impedance Bus Differential Protection

High-Impedance Bus Differential Protection Modeling in ATP/MODELS
High-Impedance Bus Differential Protection Modeling in ATP/MODELS

... In the state-of-art of relay modeling in EMTP software, most papers on the subject deal with the transmission lines (TL) distance protection [2-5]. In [2], a distance relay is modeled in EMTP program and its performance is compared with the one of a manufactured relay. In [3] and [4], distance prote ...
Line Differential Protection Under Unusual System Conditions
Line Differential Protection Under Unusual System Conditions

No Slide Title
No Slide Title

... Recognized electrical hazards Recognized electrical hazards are hazards that could cause harm to employees, such as: Bare conductors Overloaded circuits, outlets, or extension cords Underground or overhead power cables or wires Live parts Working too closely to high voltage or unrestricted access t ...
General Description Features
General Description Features

... tion circuitry, and internal MOSFETs to provide up to 300mA of current to the transformer’s primary winding. The device can be operated using the internal 425kHz oscillator, or driven by an external clock to synchronize multiple devices and control EMI behavior. Regardless of the clock source being ...
BY34462465
BY34462465

... Fig.1. Circuit of domino logic circuit During the evaluation phase; there are two possibilities for the dynamic-node voltage. If the input combination is one that corresponds to a low output, the dynamic-node voltage must be maintained at the supply voltage, VDD. On the other hand, if the input comb ...
Recognize electrical hazards that require work practices addressed
Recognize electrical hazards that require work practices addressed

CHAPTER 1
CHAPTER 1

... Although there is no fundamental zero location for electric potential, we find it useful to pretend there is. By agreement, the soil of the earth is defined as zero potential. The earth is slightly conductive so it is possible to make an electrical connection to it. We pound a half-inch diameter met ...
Installation instructions
Installation instructions

Update on 2008 Code Changes
Update on 2008 Code Changes

Hydraulic Solenoid Function - Wood
Hydraulic Solenoid Function - Wood

acadweb.centralgatech.edu
acadweb.centralgatech.edu

... – May still be problem source ...
MAX1940 Triple USB Switch with Autoreset and Fault Blanking General Description
MAX1940 Triple USB Switch with Autoreset and Fault Blanking General Description

... The MAX1940 senses the switch output voltage and selects continuous current limiting for VOUT_ greater than 1V, or short-circuit current limiting for VOUT_ less than 1V. When VOUT_ is greater than 1V, the device operates in a continuous current-limit mode that limits output current to 0.9A. When VOU ...
CONDUCTORS AND INSULATORS
CONDUCTORS AND INSULATORS

... The ampacity of a conductor, that is, the amount of current it can carry, is related to its electrical resistance: a lower-resistance conductor can carry more current. The resistance, in turn, is determined by the material the conductor is made from (as described above) and the conductor's size. For ...
A+ Guide to Hardware
A+ Guide to Hardware

... – May still be problem source ...
< 1 ... 112 113 114 115 116 117 118 119 120 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.