• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AAT4614 数据资料DataSheet下载
AAT4614 数据资料DataSheet下载

... The AAT4614 operates with input voltages ranging from 2.4V to 5.5V which, along with its extremely low operating current, makes it ideal for battery-powered applications. In cases where the input voltage drops below 2.4V, the AAT4614 MOSFET is protected from entering the saturated region of operatio ...
Transformer Disassembly and Inductor Winding
Transformer Disassembly and Inductor Winding

How You Can Build Your Own SCR/TRIAC Tester
How You Can Build Your Own SCR/TRIAC Tester

... the device remains above the holding current. Once the current falls below the holding current for an appropriate period of time, the device will switch "off". The SCR can be found in switch mode power supplies (SMPS). For your information not all SMPS use SCR. ...
Saturated Cores FCL—A New Approach
Saturated Cores FCL—A New Approach

... Abstract—The saturated cores FCL exhibits several attractive technological advantages: Inherent fail-safe and selectivity design, superconductivity is maintained during both nominal and fault states, the limiting process as well as the recovery after fault are passive and immediate, operation in lim ...
UC2852 数据资料 dataSheet 下载
UC2852 数据资料 dataSheet 下载

... for systems that would otherwise draw high peak current pulses from AC power lines. This circuit implements zero-current switched boost conversion, producing sinusoidal input currents with a minimum of external components, while keeping peak current substantially below that of fully-discontinuous co ...
TYING IN CONDUCTORS Tie wire fastens the conductor and
TYING IN CONDUCTORS Tie wire fastens the conductor and

5 - apel slice
5 - apel slice

Newport News Shipbuilding Contractor Environmental, Health and
Newport News Shipbuilding Contractor Environmental, Health and

... operations or job completion and it cannot be accomplished by other means. In such cases, the employee’s immediate supervisor must determine, on a daily basis that working on that specific energized electrical circuit is authorized, and must obtain necessary approvals from the general foreman, test ...
have  been  applied  in  industrial ... aircrafts and electric vehicle applications with more electrically
have been applied in industrial ... aircrafts and electric vehicle applications with more electrically

... have been applied in industrial fields such as military/civil aircrafts and electric vehicle applications with more electrically driven actuation systems [3], [4], which have special requirements for high-temperature operation, as well as space and weight savings. In addition, the highly reliable sy ...
EMC filters - General technical information
EMC filters - General technical information

... Directive by attaching a declaration of conformity as well as a CE conformity mark to all equipment and packaging. This implies that they assume responsibility vis-à-vis the legislators for observing the relevant emission limits and interference immunity requirements. The harmonized standards listed ...
Section Overview
Section Overview

... Designed for high operating switching frequency the Sirius SC Solid State Relays and Contactors feature a long lifespan of rugged reliability in adverse conditions, quiet operation, physically compact sizes, and snap on function modules for convenient flexible use. 3RF20 – 1-Phase Solid-State Relay, ...
ECE 310 - Course Website Directory
ECE 310 - Course Website Directory

... It would be very difficult to continually have to refer impedances to the different sides of the transformers ...
AP Physics Core Lab Summaries
AP Physics Core Lab Summaries

... An electrical circuit is present when there is evidence that electrical energy is being used. An electrical current moves or flows in an electrical circuit and is measured with an ammeter. Electrical voltage is related to energy and is measured with a voltmeter. In an electrical circuit, a strict re ...
Fuses - Jaycar
Fuses - Jaycar

AND8093/D Current Sensing Power MOSFETs
AND8093/D Current Sensing Power MOSFETs

Overvoltage and Overcurrent Protection Component Overview
Overvoltage and Overcurrent Protection Component Overview

... “Protective” is a system, not a component or device, property that depends on not only the component or device functions but also the surge and the downstream circuit withstand. To say the protective function protects in all circumstances is generally not true. In the test laboratory with a defined ...
What is an Electric generator? (back to basics)
What is an Electric generator? (back to basics)

... 3) Series generator: In series Generator, the field flux is produced by connecting the field circuit in series with the armature of the generator. 4) Commutatively Compound Generator: In commutatively compounded generator, both a shunt and a series field are present and their efforts are ...
BDTIC TLF50211EL 2.2MHz Buck Converter 5V, 500mA, with Enable and Low Quiescent...
BDTIC TLF50211EL 2.2MHz Buck Converter 5V, 500mA, with Enable and Low Quiescent...

... dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components ca ...
Product Brief TLE7183F Three-Phase Bridge driver IC for MOSFET power
Product Brief TLE7183F Three-Phase Bridge driver IC for MOSFET power

... current applications. Integrated 2-stage charge pump allows ...
ESD Systems` ESD Technical Newsletter
ESD Systems` ESD Technical Newsletter

... system. These "loops" can create potential differences from millivolts to several volts (beyond 10 Volts). If an ESD Sensitive device comes between to points in the grounding system where the potential difference is say 10 Volts, the device is at risk. In addition to ground loops, a grounding system ...
Enquiry Form (Non-Registered Generator With Capacity less than 5
Enquiry Form (Non-Registered Generator With Capacity less than 5

... (Non-Registered Generator With Capacity less than 5 MW) Installation Miscellaneous Information Does the Generating unit seek to provide non-network support of published network constraint? (Y/N) Is the Generating unit exempt from AEMO registration (less than 5MW)? (Y/N) Connection Applicant to is aw ...
Calculating the main and leakage inductance matrix of the 3
Calculating the main and leakage inductance matrix of the 3

2014 Connecting of Meters - Schuylkill Technology Center
2014 Connecting of Meters - Schuylkill Technology Center

... 2. Locates overloads and open circuits 3. Balances the loads on multiwire circuits 4. Locates electrical component malfunctions 5. Two types a. In-line In-line ammeters should always be connected in series with the circuit or component being tested. If direct current is being measured, always check ...
Protection current transformer Type VIS DIN small Form
Protection current transformer Type VIS DIN small Form

REDUR
REDUR

... Constant quality control of all products throughout and after manufacturing process using computer-controlled measuring stations. Specialist in development and manufacture of measuring transducers and measuring instruments. Manufacturer of: window-type current transformers, wound primary current tra ...
< 1 ... 121 122 123 124 125 126 127 128 129 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report