• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Transformers
Transformers

Installation manual - Harrison Hydra-Gen
Installation manual - Harrison Hydra-Gen

... All wiring must meet applicable local, state, and federal electrical codes. Accordingly, have a qualified electrician install and inspect the wiring. Mount switches and controls securely to prevent damage from vibration and road shock. All switches must be vibration proof to prevent accidental openi ...
Low-noise computer-controlled current source for quantum
Low-noise computer-controlled current source for quantum

... through an optical link. The three signals necessary—clock (CLK), data (SDI), and chip select (CS)—are sent individually from the digital outputs of the controlling computer to LED transmitters (Agilent HFBR-1412T) which convert the electrical signals to optical signals. The light travels across thr ...
ZXMS6003G 60V N-channel self protected enhancement mode IntelliFET MOSFET with programmable current limit
ZXMS6003G 60V N-channel self protected enhancement mode IntelliFET MOSFET with programmable current limit

... All types of resistive, inductive and capacitive loads in switching applications. ␮C compatible power switch for 12V and 24V DC applications. Automotive rated. Replaces electromechanical relays and discrete circuits. Linear mode capability - the current-limiting protection circuitry is designed to d ...
Specification Status: Released  PolyZen GENERAL DESCRIPTION
Specification Status: Released PolyZen GENERAL DESCRIPTION

... This polymer PTC layer responds to either extended diode heating or overcurrent events by transitioning from a low to high resistance state, also known as ”tripping”. A tripped PTC will limit current and generate voltage drop. It helps to protect both the Zener diode and the follow-on electronics an ...
Electrical Safety Training
Electrical Safety Training

... • Wire insulation melting, which may cause arcing and a fire in the area where the overload exists, even inside a wall ...
Insulation monitor - GMWISO 1.05
Insulation monitor - GMWISO 1.05

... The GMWISO insulation monitors serve for the insulation monitoring in ungrounded A.C. networks (as well as chained threephase networks in star connection) of portable stand?by electric-power generators. With GMWISO insulation monitors, it is easy to generate electric-power generators according to re ...
Infranor Variable Speed Drive Implementation
Infranor Variable Speed Drive Implementation

short circuit anaylsis and coordination study
short circuit anaylsis and coordination study

DRV8870 3.6-A Brushed DC Motor Driver (PWM
DRV8870 3.6-A Brushed DC Motor Driver (PWM

STUDY AND DESIGN OF ENLARGED AUTOMATED TEST STATION FOR GRID AUTOMATION CONTROL CABINETS
STUDY AND DESIGN OF ENLARGED AUTOMATED TEST STATION FOR GRID AUTOMATION CONTROL CABINETS

... The definition of intelligent distribution network - Smart Grid - is still nonspecific. Basically it is a renewal concept for energy systems where new energy and data solutions are used in every field of the energy system from production to consumption. /3/ Inventions such as self-healing electrical ...
Surge protection - Phoenix Contact
Surge protection - Phoenix Contact

B1506A Power Device Analyzer for Circuit Design
B1506A Power Device Analyzer for Circuit Design

Application Note No. 7038
Application Note No. 7038

... installation in countries using the IEC electrical safety system) is shipped to the United States. This equipment may not meet the North American electrical safety system requirements, which includes the National Electrical Code®, North American product standards/certifications, such as to UL, and l ...
Specification Status: Released  PolyZen GENERAL DESCRIPTION
Specification Status: Released PolyZen GENERAL DESCRIPTION

... the voltage (VIN-VOUT) at which typical qualification devices (98% devices, 95% confidence) survived at least 100 trip cycles and 24hours trip endurance at the specified voltage (VIN-VOUT) and current (IPTC). VINT Max testing is conducted using a "shorted" load (VOUT = 0V). VINT Max is a survivabili ...
AAT4670 数据资料DataSheet下载
AAT4670 数据资料DataSheet下载

... Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. ...
Specification Status: Released  PolyZen GENERAL DESCRIPTION
Specification Status: Released PolyZen GENERAL DESCRIPTION

... enhanced, precision Zener diode microassemblies. They offer resettable protection against multi-Watt fault events without the need for multi-Watt heat sinks. The Zener diode used for voltage clamping in a PolyZen micro-assembly was selected due to its relatively flat voltage vs current response. Thi ...
High Speed Hardware Design Techniques
High Speed Hardware Design Techniques

Guide to Portable Appliance Testing
Guide to Portable Appliance Testing

... grounding system for safety protection. If the earth conductor within the power cable is damaged, the hazard rises and will, therefore, require electrical testing on a more regular basis. Operators: If the equipment is likely to receive constant unreported abuse, more frequent testing will be requir ...
electrical safety guideline - University of Northern Colorado
electrical safety guideline - University of Northern Colorado

... outwards from electrical equipment creating a high-intensity flash that can damage eyesight, may damage hearing, and send damage equipment or objects through the air. A ball of gas may severely burn a worker’s body and melt metals. A. Definitions Arc Flash Hazard: A dangerous condition associated wi ...
Weighing Applications for Hazardous Areas
Weighing Applications for Hazardous Areas

Figure 1 - Texas Instruments
Figure 1 - Texas Instruments

... Texas Instruments Incorporated (‘TI”) technical, application or other design advice, services or information, including, but not limited to, reference designs and materials relating to evaluation modules, (collectively, “TI Resources”) are intended to assist designers who are developing applications ...
ADG752 数据手册DataSheet下载
ADG752 数据手册DataSheet下载

... The ADG752 is designed on a submicron process that provides low power dissipation yet gives high switching speed and low on resistance. This part is a fully bidirectional switch and can handle signals up to and including the supply rails. Break-before-make switching action ensures the input signals ...
555 IC Circuit Monostable
555 IC Circuit Monostable

... Actually really a alarm circuit, it shows how to use a 555 timer and a small glass-encapsulated mercury switch to indicate 'tilt'. The switch is mounted in its normal 'open' position, which allows the timer output to stay low, as established by C1 on start-up. When S1 is disturbed, causing its conta ...
Current-Limited, Power-Distribution Switches
Current-Limited, Power-Distribution Switches

< 1 ... 105 106 107 108 109 110 111 112 113 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.