• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Diode-connected BJT
Diode-connected BJT

165-640-900 Protective Relays P C
165-640-900 Protective Relays P C

MAX3250 ±50V Isolated, 3.0V to 5.5V, 250kbps, 2 Tx/2 Rx, RS-232 Transceiver
MAX3250 ±50V Isolated, 3.0V to 5.5V, 250kbps, 2 Tx/2 Rx, RS-232 Transceiver

... are forced into a high-impedance state. When powered off or shut down, the outputs can be driven up to ±12V relative to ISOCOM. The transmitter inputs do not have pullup resistors. All unused inputs should be connected to VCC or GND. ...
Circuit Note - Analog Devices
Circuit Note - Analog Devices

บทที่ 6 Special Transformers
บทที่ 6 Special Transformers

7762 AA Electrical Distribution (1)
7762 AA Electrical Distribution (1)

... Heat lost by convection Heat lost by radiation ...
A New Definition of Characteristic Impedance
A New Definition of Characteristic Impedance

... adjacent to an end ground plane, the terminal ...
Dc Microgrids Stability
Dc Microgrids Stability

... grids are inverted for microgrids. This fact has important implications in terms of stability and control. • Loss of stability will be also observed in microgrids as voltage deviations. © A. Kwasinski, 2014 ...
Integrating a Current Sense Resistor With a
Integrating a Current Sense Resistor With a

... other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. ...
Detection of back-fed ground fault using smart grid distribution
Detection of back-fed ground fault using smart grid distribution

the alcan glossary handbook
the alcan glossary handbook

... continuity and having the capacity to conduct safely, any current likely to be imposed on it. ...
CP4201612617
CP4201612617

... seems likely to be possible as other researchers have described ways to use far lower VDD values to maintain logic state. ...
BD6290EFV : Motor Drivers
BD6290EFV : Motor Drivers

BD6290EFV : Motor Drivers
BD6290EFV : Motor Drivers

... An excess in the absolute maximum ratings, such as supply voltage, temperature range of operating conditions, etc., can break down the devices, thus making impossible to identify breaking mode, such as a short circuit or an open circuit. If any over rated values will expect to exceed the absolute ma ...
Course Notes
Course Notes

MAX4951AE Evaluation Kit Evaluates: General Description Features
MAX4951AE Evaluation Kit Evaluates: General Description Features

... The application circuit utilizes 100I differential controlled-impedance traces and provides two SATA connectors (J1 and J2), allowing for evaluation of the MAX4951AE in a SATA environment. The characterization circuit utilizes 50I controlled-impedance traces and SMA input/output connectors, allowing ...
Novel transient-energy-based directional pilot protection method for
Novel transient-energy-based directional pilot protection method for

Complete PDF Edition (2,508 KB)
Complete PDF Edition (2,508 KB)

... by Setsuo Hosogai and Hitoshi Ito ...
M V L I
M V L I

Types Of Load Centers
Types Of Load Centers

AVR-P20 User Manual
AVR-P20 User Manual

EE411_Balanced_Three_Phase_Phasors.doc Page 1 of 6 The
EE411_Balanced_Three_Phase_Phasors.doc Page 1 of 6 The

Electromagnetism - KCPE-KCSE
Electromagnetism - KCPE-KCSE

Electrical Safety Policy Contents - Freeport
Electrical Safety Policy Contents - Freeport

... electrorefineries and may be exposed to electric shock or arc flash hazards. This policy does not prescribe operation, maintenance or installation procedures specific to all electrowinning and electrorefining systems or system components. Other applicable standards must be reviewed and adhered to in ...
Device circuit breakers - the basics
Device circuit breakers - the basics

< 1 ... 102 103 104 105 106 107 108 109 110 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report