Safety Requirements for Work On or Adjacent to the Distribution
... Establishing a physical barrier between live components and the safe area of work will ensure safe performance of the work. Clear and unambiguous communication is crucial to establishing the above. Access can also be restricted by use of road barriers around excavations, securing or locking off cab ...
... Establishing a physical barrier between live components and the safe area of work will ensure safe performance of the work. Clear and unambiguous communication is crucial to establishing the above. Access can also be restricted by use of road barriers around excavations, securing or locking off cab ...
APC FireCrest Surge
... damaged, it will self-sacrifice rather than let damaging surges get through to your equipment. Thermal Fusing - ensures that wiring faults and other catastrophic events don’t cause the Surge Protector to overheat. Safety Shutters - reduce shock hazards (with small children, this is a “must have” ...
... damaged, it will self-sacrifice rather than let damaging surges get through to your equipment. Thermal Fusing - ensures that wiring faults and other catastrophic events don’t cause the Surge Protector to overheat. Safety Shutters - reduce shock hazards (with small children, this is a “must have” ...
NEU-4, -6, -8 AND -10 E-BEAM GUN SWITCHING POWER SUPPLY
... the frame. The mounting bolts themselves will establish a proper ground connection. As a result, the Transformer Core and the Ground Shield will have the same potential as the Ground during normal operation. The Filament Transformer Primary must be connected to the Output at the rear panel of the Co ...
... the frame. The mounting bolts themselves will establish a proper ground connection. As a result, the Transformer Core and the Ground Shield will have the same potential as the Ground during normal operation. The Filament Transformer Primary must be connected to the Output at the rear panel of the Co ...
Frequency Inverter Operation on Emergency Power Generators
... connection of a regenerative power supply unit to an emergency generator. Many storage/retrieval systems are equipped with regenerative power supplies. In case of an emergency, these systems must also be able to work with a generator. If regenerated power is supplied to a generator, the following as ...
... connection of a regenerative power supply unit to an emergency generator. Many storage/retrieval systems are equipped with regenerative power supplies. In case of an emergency, these systems must also be able to work with a generator. If regenerated power is supplied to a generator, the following as ...
Wall-mount Instructions
... and/or locating Notification Appliance Circuits (NAC) and notification appliances. Some system communication circuits and/or audio circuits, for example, may require special precautions to assure immunity from electrical noise (e.g. audio crosstalk). NOTE: This equipment has been tested and found to ...
... and/or locating Notification Appliance Circuits (NAC) and notification appliances. Some system communication circuits and/or audio circuits, for example, may require special precautions to assure immunity from electrical noise (e.g. audio crosstalk). NOTE: This equipment has been tested and found to ...
MAX378/MAX379 High-Voltage, Fault-Protected Analog Multiplexers _______________General Description
... that fault current will initially be 40µA or 50µA, decaying over a few seconds to the nanoamp level. The time constant of this decay is caused by the discharge of stored charge from internal nodes, and does not compromise the fault-protection scheme. Figure 10 shows the condition of the ON channel w ...
... that fault current will initially be 40µA or 50µA, decaying over a few seconds to the nanoamp level. The time constant of this decay is caused by the discharge of stored charge from internal nodes, and does not compromise the fault-protection scheme. Figure 10 shows the condition of the ON channel w ...
QUD 2-Input NAND Gate
... used with a 47 µF de–coupling filter capacitor. The device has an internal oscillator controlled by one of two external resistors (R2 and R3) in addition to one external capacitor (C2), dependent on the application function required. The values of C2 and R2 determine the tb1 time base. Tb1 is used t ...
... used with a 47 µF de–coupling filter capacitor. The device has an internal oscillator controlled by one of two external resistors (R2 and R3) in addition to one external capacitor (C2), dependent on the application function required. The values of C2 and R2 determine the tb1 time base. Tb1 is used t ...
MAX894L/MAX895L Dual, Current-Limited, High-Side P-Channel Switches with Thermal Shutdown General Description
... The MAX894L/MAX895L are short-circuit-protected switches. In the event of an output short circuit or current-overload condition, the current through either switch is limited by the internal current-limiting error amplifier to 1.5 x ILIMIT. When the fault condition is removed, the replica error ampli ...
... The MAX894L/MAX895L are short-circuit-protected switches. In the event of an output short circuit or current-overload condition, the current through either switch is limited by the internal current-limiting error amplifier to 1.5 x ILIMIT. When the fault condition is removed, the replica error ampli ...
application note 6 - Dairyland Electrical Industries
... cause flashover of nearby insulated joints, and create a potential shock hazard. NACE Standard RP0177-2000 and Canadian Standard C22.3 No. 6-1987 both caution against using power system grounds for voltage mitigation. Spot mitigation alone cannot address all of the problems associated with induced A ...
... cause flashover of nearby insulated joints, and create a potential shock hazard. NACE Standard RP0177-2000 and Canadian Standard C22.3 No. 6-1987 both caution against using power system grounds for voltage mitigation. Spot mitigation alone cannot address all of the problems associated with induced A ...
balanced power system
... the installer and be of the highest quality available. 6. It is the responsibility of the installer to verify that proper working branch circuit power (both voltage and frequency) is supplied to the listed equipment. ...
... the installer and be of the highest quality available. 6. It is the responsibility of the installer to verify that proper working branch circuit power (both voltage and frequency) is supplied to the listed equipment. ...