STN3N45K3
... The built-in back-to-back Zener diodes have specifically been designed to enhance not only the device’s ESD capability, but also to make them safely absorb possible voltage transients that may occasionally be applied from gate to source. In this respect the Zener voltage is appropriate to achieve an ...
... The built-in back-to-back Zener diodes have specifically been designed to enhance not only the device’s ESD capability, but also to make them safely absorb possible voltage transients that may occasionally be applied from gate to source. In this respect the Zener voltage is appropriate to achieve an ...
5V Tolerance Techniques for CoolRunner-II Devices Summary
... This document describes several different methods for interfacing 5V signals to CoolRunner™II devices. These techniques may be used whenever voltage signal levels exceed the maximum input requirements of logic devices. ...
... This document describes several different methods for interfacing 5V signals to CoolRunner™II devices. These techniques may be used whenever voltage signal levels exceed the maximum input requirements of logic devices. ...
Application Note Designing VME Power Systems from Standard
... clamped, and must be limited with a series device. The best way to implement this is with a series pass MOSFET. The MOSFET is basically configured as a linear regulator, and regulates its output to less than 50V, which can be accepted by the DC-DC converter. An N-channel device should be chosen for ...
... clamped, and must be limited with a series device. The best way to implement this is with a series pass MOSFET. The MOSFET is basically configured as a linear regulator, and regulates its output to less than 50V, which can be accepted by the DC-DC converter. An N-channel device should be chosen for ...
RESEARCH ARTICLE - Bret Research Journals
... if the engine is being started, information is transferred to the master ARM which makes the GSM send a message to the mobile of the owner. The owner then sends a predefined message to the SIM(Subscriber Identity Module) mounted on the GSM. The ARM processes the message and sends the information to ...
... if the engine is being started, information is transferred to the master ARM which makes the GSM send a message to the mobile of the owner. The owner then sends a predefined message to the SIM(Subscriber Identity Module) mounted on the GSM. The ARM processes the message and sends the information to ...
P84719
... If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer’s install ...
... If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer’s install ...
1.5A Very L.D.O Voltage Regulator LM29150/1/2
... 2. Full load current(IFL ) is defined as 1.5A 3. Dropout voltage is defined as the input-to-output differential when the output voltage drops to 99% of its nominal value with Vout to Vin 4. Vin = Vout(nominal) +1V. For example, use Vin =4.3V for a 3.3V regulator or use 6V for a 5V regulator. Employ ...
... 2. Full load current(IFL ) is defined as 1.5A 3. Dropout voltage is defined as the input-to-output differential when the output voltage drops to 99% of its nominal value with Vout to Vin 4. Vin = Vout(nominal) +1V. For example, use Vin =4.3V for a 3.3V regulator or use 6V for a 5V regulator. Employ ...
ADF4007 (Rev. B)
... These two bits set the N value. See Table 4. These two bits set the status of MUXOUT and PFD polarity. See Table 5. This multiplexer output allows either the N divider output or the R divider output to be accessed externally. Digital Power Supply. This pin can range from 2.7 V to 3.3 V. Decoupling c ...
... These two bits set the N value. See Table 4. These two bits set the status of MUXOUT and PFD polarity. See Table 5. This multiplexer output allows either the N divider output or the R divider output to be accessed externally. Digital Power Supply. This pin can range from 2.7 V to 3.3 V. Decoupling c ...
BDTIC Programmable True power on sensor TLE4983C-HTN E6747 Data Sheet Version 1.1
... are called OpenPowerOn and OpenSyncVDD. For already programmed devices this initialisation procedures to testmode are not possible. The IC is still in test mode after programming the IC. It is possible to read out the programmed values as long as you do not leave the test mode. OpenPowerOn: For a sh ...
... are called OpenPowerOn and OpenSyncVDD. For already programmed devices this initialisation procedures to testmode are not possible. The IC is still in test mode after programming the IC. It is possible to read out the programmed values as long as you do not leave the test mode. OpenPowerOn: For a sh ...
LFP: High power circuit breaker Merlin Gerin 1 to 17.5 kV
... part is driven by the mechanical operating mechanism is as follows: Fig. 1: the circuit breaker is closed. Fig. 2: on opening of the main contacts (a), the current is shunted into the breaking circuit (b). Fig. 3: on separation of the arcing contacts, an electric arc appears in the expansion volume ...
... part is driven by the mechanical operating mechanism is as follows: Fig. 1: the circuit breaker is closed. Fig. 2: on opening of the main contacts (a), the current is shunted into the breaking circuit (b). Fig. 3: on separation of the arcing contacts, an electric arc appears in the expansion volume ...
MAX3314 460kbps, 1µA, RS-232-Compatible Transceiver General Description Features
... worst-case loads of 3kΩ in parallel with 1000pF. When SHDN is driven low, the transmitter is disabled and put into 3-state mode. The transmitter input does not have a pull-up resistor. Connect to ground if unused. ...
... worst-case loads of 3kΩ in parallel with 1000pF. When SHDN is driven low, the transmitter is disabled and put into 3-state mode. The transmitter input does not have a pull-up resistor. Connect to ground if unused. ...
In-System Programmability in MAX Devices
... the stylized Altera logo, specific device designations, and all other words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the trademarks and service marks of Altera Corporation in the U.S. and other countries. All other product or service names are the ...
... the stylized Altera logo, specific device designations, and all other words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the trademarks and service marks of Altera Corporation in the U.S. and other countries. All other product or service names are the ...
MM74C89 64-Bit 3-STATE Random Access Read/Write Memory
... prior to the positive to negative transition of memory enable. It is thus not necessary to hold address information stable for more than tHA after the memory is enabled (positive to negative transition of memory enable). Write Operation: Information present at the data inputs is written into the mem ...
... prior to the positive to negative transition of memory enable. It is thus not necessary to hold address information stable for more than tHA after the memory is enabled (positive to negative transition of memory enable). Write Operation: Information present at the data inputs is written into the mem ...
SYNCHRO RETRANSMISSION UNIT KW903-SP
... back-up means you can still use the autopilot. SYNCHRO OUTPUT. The “standard” and most common output is nominally 115v (50/60 Hz) reference, 90v line to line maximum voltage. Synchros are not critical on their voltage. The KW903 has several transformer taps to allow selecting reduced voltage, and by ...
... back-up means you can still use the autopilot. SYNCHRO OUTPUT. The “standard” and most common output is nominally 115v (50/60 Hz) reference, 90v line to line maximum voltage. Synchros are not critical on their voltage. The KW903 has several transformer taps to allow selecting reduced voltage, and by ...
MAX9248/MAX9250 27-Bit, 2.5MHz to 42MHz DC-Balanced LVDS Deserializers General Description
... The MAX9248/MAX9250 pair with the MAX9247 serializer to form a complete digital video transmission system. For operating frequencies less than 35MHz, the MAX9248/ MAX9250 can also pair with the MAX9217 serializer. The MAX9248 features spread-spectrum capability, allowing output data and clock to spr ...
... The MAX9248/MAX9250 pair with the MAX9247 serializer to form a complete digital video transmission system. For operating frequencies less than 35MHz, the MAX9248/ MAX9250 can also pair with the MAX9217 serializer. The MAX9248 features spread-spectrum capability, allowing output data and clock to spr ...
Laboratory Exercise: Temperature Measurement
... include voltage generators, current generators, resistance based, capacitance based and inductance based sensors. Depending upon type of the application, one should be able to select an appropriate sensor. With respect to using any type of sensor technology, the most important aspect is calibration ...
... include voltage generators, current generators, resistance based, capacitance based and inductance based sensors. Depending upon type of the application, one should be able to select an appropriate sensor. With respect to using any type of sensor technology, the most important aspect is calibration ...
SCHRACK
... 3S Relay set: RT 1-pole CO contacts (1 form C), 16 A, red LED 4S Relay set: RT 2-pole CO contacts (2 form C), 8 A, red LED ...
... 3S Relay set: RT 1-pole CO contacts (1 form C), 16 A, red LED 4S Relay set: RT 2-pole CO contacts (2 form C), 8 A, red LED ...
AC Servo Driver - tamagawa seiki co.,ltd.
... products are free of defects, except quality degradation by design or by accident on the part of the user. Even after the warranty period, ...
... products are free of defects, except quality degradation by design or by accident on the part of the user. Even after the warranty period, ...
AiT Semiconductor Inc. DESCRIPTION FEATURES APPLICATION
... capacitor is 2.0V. The voltage allowed to drop is 2.0V-0.5V=1.5V. With typical leakage current of 0.2uA the time to survive is ...
... capacitor is 2.0V. The voltage allowed to drop is 2.0V-0.5V=1.5V. With typical leakage current of 0.2uA the time to survive is ...