smart5000tel3u
... Tripp Lite's SMART5000TEL3U intelligent, line interactive UPS protects server, networking and telecommunications equipment from blackouts, voltage fluctuations and surges in a compact rackmount housing. Completely self-contained UPS system occupies only 3 rack spaces (3U) in a standard 19 inch rack, ...
... Tripp Lite's SMART5000TEL3U intelligent, line interactive UPS protects server, networking and telecommunications equipment from blackouts, voltage fluctuations and surges in a compact rackmount housing. Completely self-contained UPS system occupies only 3 rack spaces (3U) in a standard 19 inch rack, ...
Leaded varistors, AdvanceD-MP series, S14K...E2K1
... 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly poin ...
... 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly poin ...
s lec e - pSenso
... layout. Confirm that all connections are correct. Use lugged terminals. To reduce electromagnetic interference use of wires with adequate ratings and twists of the same in equal size shall be made with shortest connections. Layout of connecting cables shall be away from any internal EMI source. Cabl ...
... layout. Confirm that all connections are correct. Use lugged terminals. To reduce electromagnetic interference use of wires with adequate ratings and twists of the same in equal size shall be made with shortest connections. Layout of connecting cables shall be away from any internal EMI source. Cabl ...
DS3503 - Maxim Part Number Search
... The DS3503 can step the RW output up to WR+STEPCOUNT and down to WR-STEPCOUNT when stepping is enabled. Stepping is enabled when a nonzero STEPCOUNT value is programmed into SCR and pulses are applied to the SYNC input pin. Stepping is disabled when STEPCOUNT = 0 or no pulses are applied on the SYNC ...
... The DS3503 can step the RW output up to WR+STEPCOUNT and down to WR-STEPCOUNT when stepping is enabled. Stepping is enabled when a nonzero STEPCOUNT value is programmed into SCR and pulses are applied to the SYNC input pin. Stepping is disabled when STEPCOUNT = 0 or no pulses are applied on the SYNC ...
Aalborg Universitet
... % of the DC-link capacitor. applied for a back-to-back converter study Winding case in order capacitance value change K losses W The proposed method requires no additional hardware circuit and can be implemented by using the spare resources of existing digital controllers in most only in the researc ...
... % of the DC-link capacitor. applied for a back-to-back converter study Winding case in order capacitance value change K losses W The proposed method requires no additional hardware circuit and can be implemented by using the spare resources of existing digital controllers in most only in the researc ...
SN74LVC16374 数据资料 dataSheet 下载
... Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable f ...
... Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable f ...
ULTRA SLIMPAK G448-0002 ® Bridge Input Field Configurable Isolator
... loops from any source. Isolation protects expensive SCADA systems from ground faults and provides filtering for noise reduction which can be a significant problem with small, millivolt, bridge signals. Wide ranging flexibility allows the user to easily zero out dead-loads in weighing systems or conf ...
... loops from any source. Isolation protects expensive SCADA systems from ground faults and provides filtering for noise reduction which can be a significant problem with small, millivolt, bridge signals. Wide ranging flexibility allows the user to easily zero out dead-loads in weighing systems or conf ...
ADuC824 数据手册DataSheet 下载
... The device operates from a 32 kHz crystal with an on-chip PLL generating a high-frequency clock of 12.58 MHz. This clock is, in turn, routed through a programmable clock divider from which the MCU core clock operating frequency is generated. The microcontroller core is an 8052 and therefore 8051-ins ...
... The device operates from a 32 kHz crystal with an on-chip PLL generating a high-frequency clock of 12.58 MHz. This clock is, in turn, routed through a programmable clock divider from which the MCU core clock operating frequency is generated. The microcontroller core is an 8052 and therefore 8051-ins ...
MAX2242EVKIT.pdf
... This section lists the test equipment recommended to verify operation of the MAX2242. It is intended as a guide only, and some substitutions are possible: • One RF signal generator capable of delivering at least +10dBm of output power at the operating frequency with 802.11b comparable source • One R ...
... This section lists the test equipment recommended to verify operation of the MAX2242. It is intended as a guide only, and some substitutions are possible: • One RF signal generator capable of delivering at least +10dBm of output power at the operating frequency with 802.11b comparable source • One R ...
CS51021A, CS51022A, CS51023A, CS51024A
... Blanking is disabled when VFB is less than 2.0 V so that the minimum on−time of the controller does not have an additional 55 ns of delay time during fault conditions. For the remaining portion of the switching period, the current sense signal, combined with a fraction of the slope compensation volt ...
... Blanking is disabled when VFB is less than 2.0 V so that the minimum on−time of the controller does not have an additional 55 ns of delay time during fault conditions. For the remaining portion of the switching period, the current sense signal, combined with a fraction of the slope compensation volt ...
SYSMAC CPM1A Programmable Controllers Operation Manual
... explanation of operating procedures for the Programming Consoles. It also introduces the capabilities of the SYSMAC Support Software (SSS). Read this manual first to acquaint yourself with the CPM1A. The CPM1/CPM1A/CPM2A/CPM2C/SRM1(-V2) Programming Manual (W353) provides detailed descriptions of the ...
... explanation of operating procedures for the Programming Consoles. It also introduces the capabilities of the SYSMAC Support Software (SSS). Read this manual first to acquaint yourself with the CPM1A. The CPM1/CPM1A/CPM2A/CPM2C/SRM1(-V2) Programming Manual (W353) provides detailed descriptions of the ...
cable tester ct100
... This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate ...
... This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate ...
1 Data Representation
... • The list of characters that a computer can handle is called the character set. • ASCII character set was introduced so that all computers would use the same codes to represent the same characters • Control characters are included in the character set that tell the computer to do things, for instan ...
... • The list of characters that a computer can handle is called the character set. • ASCII character set was introduced so that all computers would use the same codes to represent the same characters • Control characters are included in the character set that tell the computer to do things, for instan ...
abridged data sheet - Maxim Part Number Search
... relevant supply voltage range are guaranteed by design and characterization. Typical values are not guaranteed. System requirement. Maximum allowable pullup resistance is a function of the number of 1-Wire devices in the system and 1-Wire recovery times. The specified value here applies to systems w ...
... relevant supply voltage range are guaranteed by design and characterization. Typical values are not guaranteed. System requirement. Maximum allowable pullup resistance is a function of the number of 1-Wire devices in the system and 1-Wire recovery times. The specified value here applies to systems w ...
MAX3187 ±15kV ESD-Protected, EMC-Compliant, 230kbps, Dual RS-232 Serial Port for Motherboards/Desktops _______________General Description
... are incorporated on all pins to protect against electrostatic discharges (ESD) encountered during handling and assembly. The MAX3187 driver outputs and receiver inputs have extra protection against static electricity found in normal operation. Maxim’s engineers developed state-of-the-art structures ...
... are incorporated on all pins to protect against electrostatic discharges (ESD) encountered during handling and assembly. The MAX3187 driver outputs and receiver inputs have extra protection against static electricity found in normal operation. Maxim’s engineers developed state-of-the-art structures ...
Data Sheet (current)
... This symbol advises the user that the terminal(s) so marked must not be connected to a circuit point at which the voltage with respect to earth ground exceeds 600V. This symbol adjacent to one or more terminals identifies them as being associated with ranges that may, in normal use, be subjected to ...
... This symbol advises the user that the terminal(s) so marked must not be connected to a circuit point at which the voltage with respect to earth ground exceeds 600V. This symbol adjacent to one or more terminals identifies them as being associated with ranges that may, in normal use, be subjected to ...
Future Trends in Microelectronics – Impact on Detector Readout
... applied to a logic circuit one finds easily that transistor density goes up by α2, speed goes up by α, and power density remains constant. Industry has capitalized on this scaling behavior, adopting a model where a new process generation is introduced into production every 2 years, with α ≅√2. With ...
... applied to a logic circuit one finds easily that transistor density goes up by α2, speed goes up by α, and power density remains constant. Industry has capitalized on this scaling behavior, adopting a model where a new process generation is introduced into production every 2 years, with α ≅√2. With ...