S280-70-2
... Control parameters can also be programmed via a personal computer connected to the control through the front panel RS-232 port. Control programming, interrogation, and operations are performed with Form 6 ProView interface software on a personal computer. The ProView interface program software inclu ...
... Control parameters can also be programmed via a personal computer connected to the control through the front panel RS-232 port. Control programming, interrogation, and operations are performed with Form 6 ProView interface software on a personal computer. The ProView interface program software inclu ...
Space Qualification and Performance Results of the SIDECAR ASIC
... can be operated at speeds up to 80 Mbits per line in single data rate mode (one bit per clock cycle) with a maximum bus width of 24 signals. Therefore, the maximum data bandwidth is about 1.9 Gbit/s and corresponds to 32 analog detector channels digitized at 5 MHz with 12 bit resolution. Table 1 sum ...
... can be operated at speeds up to 80 Mbits per line in single data rate mode (one bit per clock cycle) with a maximum bus width of 24 signals. Therefore, the maximum data bandwidth is about 1.9 Gbit/s and corresponds to 32 analog detector channels digitized at 5 MHz with 12 bit resolution. Table 1 sum ...
ME371, MT371 ME372, MT372
... repeater mode and transmit data in both directions, even with meters with which it can not communicate directly. Data transmission of max. 7 remote meters which temporarily operate in the repeater mode increases efficiency of communication and distance between the meters and a data concentrator. C ...
... repeater mode and transmit data in both directions, even with meters with which it can not communicate directly. Data transmission of max. 7 remote meters which temporarily operate in the repeater mode increases efficiency of communication and distance between the meters and a data concentrator. C ...
Relay Products Shortform Catalog
... 1) Please contact TE Connectivity application engineering support for details concerning Power Relay K-S. 2) Please contact TE Connectivity application engineering support for higher current (LCC). 3) QC=quick connect. 4) For products V23086-C1021-A502 / V23086-C1001-A602 lamp load/flasher. 5) Curre ...
... 1) Please contact TE Connectivity application engineering support for details concerning Power Relay K-S. 2) Please contact TE Connectivity application engineering support for higher current (LCC). 3) QC=quick connect. 4) For products V23086-C1021-A502 / V23086-C1001-A602 lamp load/flasher. 5) Curre ...
understanding voltage stability - Sacramento
... and leave the specific details for individual investigation. Understanding what causes voltage instability and why this may cascade into a voltage collapse requires knowledge of how key components of the power system are affected by low voltage. Power System components will respond at different time ...
... and leave the specific details for individual investigation. Understanding what causes voltage instability and why this may cascade into a voltage collapse requires knowledge of how key components of the power system are affected by low voltage. Power System components will respond at different time ...
of documents submitted - Orissa Electricity Regulatory Commission
... The technical bid shall be opened on 06.06.12 at 4.00 P.M in the OERC office, Bhubaneswar in presence of such bidders or their authorized representatives, who may like to be present at the time of opening. (Pl. Attach copy of valid STCC/ VAT clearance certificate, (Please attach copy of audited bala ...
... The technical bid shall be opened on 06.06.12 at 4.00 P.M in the OERC office, Bhubaneswar in presence of such bidders or their authorized representatives, who may like to be present at the time of opening. (Pl. Attach copy of valid STCC/ VAT clearance certificate, (Please attach copy of audited bala ...
GA-G33M-S2H
... The revision number on your motherboard looks like this: "REV: X.X." For example, "REV: 1.0" means the revision of the motherboard is 1.0. Check your motherboard revision before updating motherboard BIOS, drivers, or when looking for technical information. ...
... The revision number on your motherboard looks like this: "REV: X.X." For example, "REV: 1.0" means the revision of the motherboard is 1.0. Check your motherboard revision before updating motherboard BIOS, drivers, or when looking for technical information. ...
74AVCH4T245 1. General description 4-bit dual supply translating transceiver with configurable
... for translating between any of the low voltage nodes (0.8 V, 1.2 V, 1.5 V, 1.8 V, 2.5 V and 3.3 V). Pins nAn, nOE and nDIR are referenced to VCC(A) and pins nBn are referenced to VCC(B). A HIGH on nDIR allows transmission from nAn to nBn and a LOW on nDIR allows transmission from nBn to nAn. The out ...
... for translating between any of the low voltage nodes (0.8 V, 1.2 V, 1.5 V, 1.8 V, 2.5 V and 3.3 V). Pins nAn, nOE and nDIR are referenced to VCC(A) and pins nBn are referenced to VCC(B). A HIGH on nDIR allows transmission from nAn to nBn and a LOW on nDIR allows transmission from nBn to nAn. The out ...
Thesis-Reporttt-4
... To safe people and belongings from harm, electric defects in a power grid as in electrical equipment such as Power Transformer must be cleared rapidly. In past days of power systems the defects clarification was done by the service staff, which optically diagnose the faults and by hand monitored a t ...
... To safe people and belongings from harm, electric defects in a power grid as in electrical equipment such as Power Transformer must be cleared rapidly. In past days of power systems the defects clarification was done by the service staff, which optically diagnose the faults and by hand monitored a t ...
ELAB-080 - Osciloskopy
... The application is run as up to 5 separate windows, one with controls for the instruments, 2 other windows showing the results of the DSO and LA, spectral analysis (FFT) window for DSO analysis, and final window showing the AWG waveform (see picture). Each of these windows can be toggled on or off, ...
... The application is run as up to 5 separate windows, one with controls for the instruments, 2 other windows showing the results of the DSO and LA, spectral analysis (FFT) window for DSO analysis, and final window showing the AWG waveform (see picture). Each of these windows can be toggled on or off, ...
N3 Instruction Manual
... Do not touch any circuit boards or components while the charging indicator is still lit after turned the power off. (The light will fade) z Do not wire when the inverter is electrified. Do not check parts and signals on circuit boards during the inverter operation. z Do not disassemble the inverter ...
... Do not touch any circuit boards or components while the charging indicator is still lit after turned the power off. (The light will fade) z Do not wire when the inverter is electrified. Do not check parts and signals on circuit boards during the inverter operation. z Do not disassemble the inverter ...
514 - NDIR analyzer - Teledyne Analytical Instruments
... The energy source for the analyzer is provided by a high intensity quartz iodine lamp located in the source module. Quartz iodine was chosen because it produces sufficient NIR to operate the system and maintains a nearly constant brightness over its lifetime. (See Figures 2-1 and 2-2). This energy i ...
... The energy source for the analyzer is provided by a high intensity quartz iodine lamp located in the source module. Quartz iodine was chosen because it produces sufficient NIR to operate the system and maintains a nearly constant brightness over its lifetime. (See Figures 2-1 and 2-2). This energy i ...
... This manual is intended for use in a linear semiconductor devices course and is appropriate for two and four year electrical engineering technology curriculums. The manual contains sufficient exercises for a typical 15 week course using a two to three hour practicum period. The topics cover basic di ...
Emon Meter Installation
... located on the top and bottom of the meter enclosure. This E-Mon DMon meter model must be installed indoors, in an area that is free from moisture and extreme temperatures. (An optional outdoor enclosure is available; contact E-Mon for details.) Assemble and install the current sensors around the co ...
... located on the top and bottom of the meter enclosure. This E-Mon DMon meter model must be installed indoors, in an area that is free from moisture and extreme temperatures. (An optional outdoor enclosure is available; contact E-Mon for details.) Assemble and install the current sensors around the co ...
230V FX Drives - Accu Electric Motors Inc.
... port. RS-423 is signal compatible with both RS-232C and RS-422 serial communications protocol. Programming of motion parameters, input/ output functions, operating modes, indexes, and setup parameters can be accomplished through this serial interface port. Amplifier status and motor position informa ...
... port. RS-423 is signal compatible with both RS-232C and RS-422 serial communications protocol. Programming of motion parameters, input/ output functions, operating modes, indexes, and setup parameters can be accomplished through this serial interface port. Amplifier status and motor position informa ...
AD8271 数据手册DataSheet 下载
... the output current to approximately 100 mA (see Figure 22 for more information). Although the short-circuit condition itself does not damage the part, the heat generated by the condition can cause the part to exceed its maximum junction temperature, with corresponding negative effects on reliability ...
... the output current to approximately 100 mA (see Figure 22 for more information). Although the short-circuit condition itself does not damage the part, the heat generated by the condition can cause the part to exceed its maximum junction temperature, with corresponding negative effects on reliability ...