• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Fluke Corporation Fluke 83V Industrial Multimeter Manual
Fluke Corporation Fluke 83V Industrial Multimeter Manual

... Each Fluke 20, 70, 80, 170 and 180 Series DMM will be free from defects in material and workmanship for its lifetime. As used herein, “lifetime” is defined as seven years after Fluke discontinues manufacturing the product, but the warranty period shall be at least ten years from the date of purchase ...
Analog-to-Digital Conversion via Time
Analog-to-Digital Conversion via Time

... Conventional voltage-mode analog-to-digital converters use voltage amplifiers, voltage comparators, and switch capacitor networks to perform their signal processing. When compared to digital circuitry, these analog circuit blocks consume significant power, occupy large silicon areas, and operate at ...
EasyWeld
EasyWeld

Chapter 4 Specifying Simulation Output
Chapter 4 Specifying Simulation Output

... † Only created if a .POST statement is used to generate graphical data. †† Requires a .GRAPH statement or a pointer to a file exists in the meta.cfg file. This file is not generated by the PC version of Star-Hspice. ††† Only created if a .FFT statement is used. ...
cascaded and hybrid multilevel inverters with reduced number of
cascaded and hybrid multilevel inverters with reduced number of

Octal LNA/VGA/AAF/12-Bit ADC and CW I/Q Demodulator AD9276
Octal LNA/VGA/AAF/12-Bit ADC and CW I/Q Demodulator AD9276

... battery life for portable applications. A standby mode option allows quick power-up for power cycling. In CW Doppler operation, the VGA, AAF, and ADC are powered down. The power of the TGC path scales with selectable ADC speed power modes. The ADC contains several features designed to maximize flexi ...
AD7466 数据手册DataSheet 下载
AD7466 数据手册DataSheet 下载

... Acquisition time/power-up time from power-down. See the Terminology section. The acquisition time is the time required for the part to acquire a full-scale step input value within ±1 LSB or a 30 kHz ac input value within ±0.5 LSB. VDD = 1.6 V. 1.8 V ≤ VDD ≤ 3.6 V. Minimum quiet time required between ...
jClamp PDF Help - SciSoft Company
jClamp PDF Help - SciSoft Company

... MD. There is still a jitter that I detect that MD cannot recapitulate. I think it is present not just in jClamp but also in Clampex. I will fix when they acknowledge and fix. In order to use MD (Axon) boards you will need to copy some files to the jClamp32 directory. The required files change, so em ...
NVT2003/04/06 Bidirectional voltage-level translator for open
NVT2003/04/06 Bidirectional voltage-level translator for open

... Table 6, Table 7 and Table 8 contain suggested minimum values of pull-up resistors for the PCA9306 and NVT20xx devices with typical voltage translation levels and drive currents. The calculated values assume that both drive currents are the same. VOL = VIL = 0.1  VCC and accounts for a 5 % VCC tol ...
8. operation instructions
8. operation instructions

...  Ensure system is in maintenance DC UPS mode or external wrap-around DC UPS mode before work is started.  This manual is designed as an aid tool in diagnosing problems that may arise. Always On does not assume responsibility if information causes injuries.  Apart from the front door, do not open ...
Xcell27
Xcell27

... single device to interface with multiple stan- ...
Solid State Relays Common Precautions
Solid State Relays Common Precautions

... commonly malfunction or fail. Short-circuit failures represent the main failure mode and can result in an inability to shut OFF the load. Therefore, for fail-safe operation of control circuits that use SSRs, do not use circuits that shut OFF the load power supply only with an SSR, but rather also us ...
74HC4040; 74HCT4040 1. General description 12-stage binary ripple counter
74HC4040; 74HCT4040 1. General description 12-stage binary ripple counter

... 001aad589 ...
10 Gb/s Radiation-Hard VCSEL Array Driver
10 Gb/s Radiation-Hard VCSEL Array Driver

... of the ASIC will first be fabricated in a 65 nm CMOS process before expanding to 12 channels. We will present the circuit designs together with results from a simulation of the extracted layout with parasitics included. II. RESULTS FROM A 5 GB/S VCSEL ARRAY DRIVER We have successfully designed a VCS ...
Grid Code
Grid Code

... If the investigations show that the grid conditions at the grid connection nodes are insufficient for correct operation of a connectee’s plant, ENE defines appropriate measures in the grid connection concept for adapting the connectee’s plants. If a conversion, extension, grid reinforcement or other ...
Application Hints TJA1055T Fault
Application Hints TJA1055T Fault

Generic Specifications for Hi-Performance Power Metering with
Generic Specifications for Hi-Performance Power Metering with

Power Specialist`s App Note Book
Power Specialist`s App Note Book

... DC operating points, and allowed the simulated circuit to operate in both conduction modes, regardless of the analysis type (AC, DC or TRAN). Although these models are 15 years old, other models have been introduced since then, our example circuits which have been based upon them will demonstrate ho ...
LX7730 Datasheet
LX7730 Datasheet

... universal inputs can also function as variable bi-level inputs with the threshold set by an internal 8 bit digital-toanalog converter. There is an additional 10 bit digital-toanalog current DAC with complementary outputs. Finally there are 8 fixed threshold bi-level inputs. The LX7730 is register pr ...
Ultra low noise amplifiers
Ultra low noise amplifiers

... AD has the same noise and also offers full DC specification and lower input currents at expense of higher input current noise. 4. Practical recommendations for design of low noise amplifiers Every resistor is a noise source so it is necessary to keep all resistors in a signal path (and also signal s ...
synchronisation of two camcorders with pi controller – 3d lanc master
synchronisation of two camcorders with pi controller – 3d lanc master

... camcorders which are equipped with connectors dedicated for synchronisation. However, those inputs are not available in consumer video equipment, so taking quality stereoscopic video stays out of reach for ordinary amateur videographer. Video frames are taken from camcorder’s CCD chip about 25 (PAL) ...
ppt - glast lat
ppt - glast lat

S280-70-2
S280-70-2

... Control parameters can also be programmed via a personal computer connected to the control through the front panel RS-232 port. Control programming, interrogation, and operations are performed with Form 6 ProView interface software on a personal computer. The ProView interface program software inclu ...
Overcurrent Protection / 7SJ62
Overcurrent Protection / 7SJ62

... The high-impedance measurement principle is an uncomplicated and sensitive method for detecting ground faults, especially on transformers. It can also be applied to motors, generators and reactors when these are operated on an grounded network. When the high-impedance measurement principle is applie ...
PowerCut 1300/1600
PowerCut 1300/1600

... This equipment will perform in conformity with the description thereof contained in this manual and accompanying labels and/or inserts when installed, operated, maintained and repaired in accordance with the instructions provided. This equipment must be checked periodically. Malfunctioning or poorly ...
< 1 ... 62 63 64 65 66 67 68 69 70 ... 1306 >

Immunity-aware programming

When writing firmware for an embedded system, immunity-aware programming refers to programming techniques which improve the tolerance of transient errors in the program counter or other modules of a program that would otherwise lead to failure. Transient errors are typically caused by single event upsets, insufficient power, or by strong electromagnetic signals transmitted by some other ""source"" device.Immunity-aware programming is an example of defensive programming and EMC-aware programming. Although most of these techniques apply to the software in the ""victim"" device to make it more reliable, a few of these techniques apply to software in the ""source"" device to make it emit less unwanted noise.