AF-17 Electronic Positioner
... A. The AC AF-17 board 4-20 mA signal input circuit is protected with a 62 mA fuse (F1). The fuse is used to protect the input circuit from an excessively high voltage. The fuse used in the input circuit is a Littlefuse PICO II very fast-acting fuse rated at 62 mA. There is a spare fuse located on th ...
... A. The AC AF-17 board 4-20 mA signal input circuit is protected with a 62 mA fuse (F1). The fuse is used to protect the input circuit from an excessively high voltage. The fuse used in the input circuit is a Littlefuse PICO II very fast-acting fuse rated at 62 mA. There is a spare fuse located on th ...
Programmable Gain Amplifier (PGA)
... adjusting two resistors, Ra and Rb (see Figure 2. PGA Schematic). Ra may be set to either 20 kΩ or 40 kΩ. Rb is set between 20 kΩ and 1000 kΩ to generate the gain values selectable in either the parameter dialog or the PGA_SetGain() function. The block has a programmable capacitor in parallel with t ...
... adjusting two resistors, Ra and Rb (see Figure 2. PGA Schematic). Ra may be set to either 20 kΩ or 40 kΩ. Rb is set between 20 kΩ and 1000 kΩ to generate the gain values selectable in either the parameter dialog or the PGA_SetGain() function. The block has a programmable capacitor in parallel with t ...
BA324C Intrinsically safe Loop-powered 4½ digit field mounting
... displayed by the indicator are shown within inverted commas e.g. 'CAL' and ' ALr2'. Access to the programme menu is obtained by operating the P and E push-buttons simultaneously. If the instrument is not protected by a security code the first parameter 'root' will be displayed. If a security code ot ...
... displayed by the indicator are shown within inverted commas e.g. 'CAL' and ' ALr2'. Access to the programme menu is obtained by operating the P and E push-buttons simultaneously. If the instrument is not protected by a security code the first parameter 'root' will be displayed. If a security code ot ...
Lecture 03
... NMH: noise margin for high input NML: noise margin for low input Vth: threshold voltage Noise margins are typically around 0.4 VDD; close to half power-supply voltage CMOS ideal from noise-immunity standpoint ...
... NMH: noise margin for high input NML: noise margin for low input Vth: threshold voltage Noise margins are typically around 0.4 VDD; close to half power-supply voltage CMOS ideal from noise-immunity standpoint ...
Imrie® Diagnostic Testing
... 11. Crank the engine vigorously and note the voltage on the meters 400v DC scale. The meter readings should be close to the voltages specified. 12. If voltage reading is as specified, the CDI unit or kill switch is faulty, if the kill switch is OK then replace the CDI unit. 13. ...
... 11. Crank the engine vigorously and note the voltage on the meters 400v DC scale. The meter readings should be close to the voltages specified. 12. If voltage reading is as specified, the CDI unit or kill switch is faulty, if the kill switch is OK then replace the CDI unit. 13. ...
6.0 Front Control Panel
... exceeded. The static transfer switch control logic will contain an automatic transfer control that senses the status of the inverter logic signals, and operating and alarm conditions. This control circuit will provide an uninterrupted transfer of the load to a normal input source (or alternate bypas ...
... exceeded. The static transfer switch control logic will contain an automatic transfer control that senses the status of the inverter logic signals, and operating and alarm conditions. This control circuit will provide an uninterrupted transfer of the load to a normal input source (or alternate bypas ...
Helios Rectifier 25/48 Single Phase
... confidential and shall protect same, in whole or in part, from disclosure and dissemination to all third parties, and use the same for start-up, operation, troubleshooting, and maintenance purposes only. Any modification to the equipment must be approved by the person responsible for product safety, ...
... confidential and shall protect same, in whole or in part, from disclosure and dissemination to all third parties, and use the same for start-up, operation, troubleshooting, and maintenance purposes only. Any modification to the equipment must be approved by the person responsible for product safety, ...
4.5. Current Mode Instrumentation Amplifiers
... performed using surface electrodes on the skin of the chest. Therefore, they can be considered as non-invasive. On the other hand, the measurement of the EMG signals are generally considered as non-invasive, unless needle electrodes are used in order to monitor single motor unit potentials. Referrin ...
... performed using surface electrodes on the skin of the chest. Therefore, they can be considered as non-invasive. On the other hand, the measurement of the EMG signals are generally considered as non-invasive, unless needle electrodes are used in order to monitor single motor unit potentials. Referrin ...
15-60kVA
... A. Normal: The inverter shall supply AC power continuously to the critical loads. The inverter output shall be synchronized with the bypass AC power source provided that the bypass AC power source is within the specified frequency range. The rectifier shall convert the normal AC input power to DC po ...
... A. Normal: The inverter shall supply AC power continuously to the critical loads. The inverter output shall be synchronized with the bypass AC power source provided that the bypass AC power source is within the specified frequency range. The rectifier shall convert the normal AC input power to DC po ...
S260-80-2
... Operation on AC Power Only The iMC switch control continuously monitors the battery voltage. To prevent battery damage, the control shuts down automatically upon detection of low battery voltage (below 22 V dc) for 60 seconds. During such occurrence the Automated M-Force switch will be electrically ...
... Operation on AC Power Only The iMC switch control continuously monitors the battery voltage. To prevent battery damage, the control shuts down automatically upon detection of low battery voltage (below 22 V dc) for 60 seconds. During such occurrence the Automated M-Force switch will be electrically ...
IVGTF Task 1-3 Interconnection Requirements for VG
... Fault ride-through and frequency ride-through capability of generators will be covered by the NERC standards under development. TPL-001-2 will cover the planning assessment for new and existing generators to ensure that grid performance reliability standards are met. PRC-024-1 will provide additiona ...
... Fault ride-through and frequency ride-through capability of generators will be covered by the NERC standards under development. TPL-001-2 will cover the planning assessment for new and existing generators to ensure that grid performance reliability standards are met. PRC-024-1 will provide additiona ...
S280-70-15
... and connects to the Recloser Interface (RIF) module to provide isolation for reliable operation. Voltages for metering are connected to the analog input module. Line current flowing through the recloser is converted by the CPU module to a digital signal suitable for metering and fault current calcul ...
... and connects to the Recloser Interface (RIF) module to provide isolation for reliable operation. Voltages for metering are connected to the analog input module. Line current flowing through the recloser is converted by the CPU module to a digital signal suitable for metering and fault current calcul ...
TPS5130 数据资料 dataSheet 下载
... The high-side driver is designed to drive high current and low rDS(on) N-channel MOSFET(s). The current rating of the driver is 1.2 A at source and sink. When configured as a floating driver, a 5-V bias voltage is delivered from VREF5 pin. The instantaneous drive current is supplied by the flying ca ...
... The high-side driver is designed to drive high current and low rDS(on) N-channel MOSFET(s). The current rating of the driver is 1.2 A at source and sink. When configured as a floating driver, a 5-V bias voltage is delivered from VREF5 pin. The instantaneous drive current is supplied by the flying ca ...
4.5 Rectifier Circuits
... We then determine WHEN our reverse bias assumption is valid, by solving the inequality vDi f v I 0 for vI. For the example used here, we would find that the IDEAL diode is reverse biased WHEN v I 5.0 V . For junction diode circuits with multiple diodes, we may have to repeat this entire pro ...
... We then determine WHEN our reverse bias assumption is valid, by solving the inequality vDi f v I 0 for vI. For the example used here, we would find that the IDEAL diode is reverse biased WHEN v I 5.0 V . For junction diode circuits with multiple diodes, we may have to repeat this entire pro ...
Substrate Coupling in Digital Circuits in Mixed-Signal Smart
... pulse at the same time. This type of noise is often referred to as uniform noise. In the second case, depicted in Fig. 4(b), the noise is not in phase, that is the transistors in the inverters are affected by the substrate noise pulses at different times. For CMOS circuits, latch-up and metastabilit ...
... pulse at the same time. This type of noise is often referred to as uniform noise. In the second case, depicted in Fig. 4(b), the noise is not in phase, that is the transistors in the inverters are affected by the substrate noise pulses at different times. For CMOS circuits, latch-up and metastabilit ...
An Enhanced Faraday Cup for Rapid Determination of Power
... multiple beam profiles in a fraction of a second as the beam is oscillated in a circular pattern over the tungsten disk. These individual beam profiles are then reconstructed using a computed tomographic method to render an image of the beam shape, size, and power density distribution (Ref. 10). All ...
... multiple beam profiles in a fraction of a second as the beam is oscillated in a circular pattern over the tungsten disk. These individual beam profiles are then reconstructed using a computed tomographic method to render an image of the beam shape, size, and power density distribution (Ref. 10). All ...
Parallel port interfacing made easy: Simple circuits and
... Those are the typical I/O addresses used in ISA bus based systems. In PCI bus based systems the LPT1 port on motherboard is typically at I/O-address 378h or 3BCh. If the systems has extra LPT ports on multi-IO card in PCI bus, those extra LPT ports work differently than the "normal parallel port" de ...
... Those are the typical I/O addresses used in ISA bus based systems. In PCI bus based systems the LPT1 port on motherboard is typically at I/O-address 378h or 3BCh. If the systems has extra LPT ports on multi-IO card in PCI bus, those extra LPT ports work differently than the "normal parallel port" de ...
M4315-PRO Instructions
... The M4315-PRO features Panamax’s revolutionary AVM (Automatic Voltage Monitoring) circuit, and our exclusive Linear Filtering Technology (LiFT). Together, these technologies comprise precisely what our customers have come to expect from Panamax: uncompromised AC protection and purification. Outlets: ...
... The M4315-PRO features Panamax’s revolutionary AVM (Automatic Voltage Monitoring) circuit, and our exclusive Linear Filtering Technology (LiFT). Together, these technologies comprise precisely what our customers have come to expect from Panamax: uncompromised AC protection and purification. Outlets: ...
SiloPatrol® Auxiliary Output Enclosure (AOE)
... Specifications). 2) Circuit Separation - Two cable entry locations are provided to aid in maintaining separation of "hazardous live" (typically mains voltages such as 115Vac and 230Vac) and limited circuits (typically control voltages less than 30Vrms or 42.4VDC). However, since the SMU's single wir ...
... Specifications). 2) Circuit Separation - Two cable entry locations are provided to aid in maintaining separation of "hazardous live" (typically mains voltages such as 115Vac and 230Vac) and limited circuits (typically control voltages less than 30Vrms or 42.4VDC). However, since the SMU's single wir ...