D-500 - datakom electronics engineering as
... 500mA @ 12VDC. (All options included, digital outputs open.) 250mA @ 24VDC. (All options included, digital outputs open.) ...
... 500mA @ 12VDC. (All options included, digital outputs open.) 250mA @ 24VDC. (All options included, digital outputs open.) ...
Manual for the Ares Modeler Module
... Also, once you start a connector, you can cancel it by pressing the “Esc” (escape) key. (Another convenient way to delete a connector is to click on it close to an icon for editing, and then just press the "Esc" (escape) key to cancel it.) Once a connector has been put in place, it can be detatched ...
... Also, once you start a connector, you can cancel it by pressing the “Esc” (escape) key. (Another convenient way to delete a connector is to click on it close to an icon for editing, and then just press the "Esc" (escape) key to cancel it.) Once a connector has been put in place, it can be detatched ...
Discrete OTA Measurement Report #1
... have been measured to higher current values yet. This graph also shows, and it was witnessed during test, that the discrete OTA doesn’t drift and has more stable readings than the CA3280. The current shown on the y-axis in Figure 10 is taken to be the ...
... have been measured to higher current values yet. This graph also shows, and it was witnessed during test, that the discrete OTA doesn’t drift and has more stable readings than the CA3280. The current shown on the y-axis in Figure 10 is taken to be the ...
TPS23750 Flyback-Converter Evaluation Board
... • All leads should be as short as possible with wide power traces and paired signal and return. • There should not be any crossovers of signals from one part of the flow to another. • Spacing consistent with safety standards like IEC60950 must be observed between the 48-V input voltage rails and bet ...
... • All leads should be as short as possible with wide power traces and paired signal and return. • There should not be any crossovers of signals from one part of the flow to another. • Spacing consistent with safety standards like IEC60950 must be observed between the 48-V input voltage rails and bet ...
Analog input module AI 4xRTD/TC 2-/3-/4-wire HF
... ● Resolution: Up to 16 bits including sign ● Voltage measurement type can be set per channel ● Resistor measurement type can be set per channel ● Thermal resistor (RTD) measurement type can be set per channel ● Thermocouple (TC) measurement type can be set per channel ● Configurable diagnostics for ...
... ● Resolution: Up to 16 bits including sign ● Voltage measurement type can be set per channel ● Resistor measurement type can be set per channel ● Thermal resistor (RTD) measurement type can be set per channel ● Thermocouple (TC) measurement type can be set per channel ● Configurable diagnostics for ...
WT1800 Precision Power Analyzer Getting Started Guide User’s
... To prevent fire and electric shock, only use a power cord supplied by YOKOGAWA. The main power plug must be plugged into an outlet with a protective earth terminal. Do not disable this protection by using an extension cord without protective earth grounding. Additionally, do not use the power cord s ...
... To prevent fire and electric shock, only use a power cord supplied by YOKOGAWA. The main power plug must be plugged into an outlet with a protective earth terminal. Do not disable this protection by using an extension cord without protective earth grounding. Additionally, do not use the power cord s ...
Implementation and Applications of Current
... If a completely floating programable current source is needed, use the circuit shown in Figure 16. It is basically the same as the current source shown in Figure 12 except that R2 is driven by a MOSFET. Since no current flows in the gate of the MOSFET or the inputs of the op amp, all current that en ...
... If a completely floating programable current source is needed, use the circuit shown in Figure 16. It is basically the same as the current source shown in Figure 12 except that R2 is driven by a MOSFET. Since no current flows in the gate of the MOSFET or the inputs of the op amp, all current that en ...
Features Applications Description Functional Block Diagram Logic
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
Precision Dual-Channel Difference Amplifier AD8270
... output current to approximately 100 mA (see Figure 19 for more information). While the short-circuit condition itself does not damage the device, the heat generated by the condition can cause the device to exceed its maximum junction temperature, with corresponding negative effects on reliability. ...
... output current to approximately 100 mA (see Figure 19 for more information). While the short-circuit condition itself does not damage the device, the heat generated by the condition can cause the device to exceed its maximum junction temperature, with corresponding negative effects on reliability. ...
Memristor-The Missing Circuit Element
... We remark that the above criterion remains valid if the “differentiability” condition is replaced by a “continuity” condition, provided that the left- and right-hand derivative at each point on the cp-q curve exists. This criterion shows that only memristors characterized by a monotonically increasi ...
... We remark that the above criterion remains valid if the “differentiability” condition is replaced by a “continuity” condition, provided that the left- and right-hand derivative at each point on the cp-q curve exists. This criterion shows that only memristors characterized by a monotonically increasi ...
MAX1533A/MAX1537A High-Efficiency, 5x Output, Main Power-Supply Controllers for Notebook Computers General Description
... the input voltage to go down to 8.3V before duty-cycle overlap occurs, compared to 180° out-of-phase regulators where the duty-cycle overlap occurs when the input drops below 10V. Output current sensing provides accurate current limit using a sense resistor. Alternatively, power dissipation can be r ...
... the input voltage to go down to 8.3V before duty-cycle overlap occurs, compared to 180° out-of-phase regulators where the duty-cycle overlap occurs when the input drops below 10V. Output current sensing provides accurate current limit using a sense resistor. Alternatively, power dissipation can be r ...
Ladda PDF Lärdomsprov som heltext
... action is achieved by setting right parameters to the transformer IED’s automatic voltage control function. The automatic controllers that are going to be used are RET670 transformer IED and generator automatic voltage regulator Unitrol. The thesis includes a theoretical study about generator, step- ...
... action is achieved by setting right parameters to the transformer IED’s automatic voltage control function. The automatic controllers that are going to be used are RET670 transformer IED and generator automatic voltage regulator Unitrol. The thesis includes a theoretical study about generator, step- ...
RIGOL User’s Guide DM3068 Feb. 2014
... In order to prevent electric shock, DM3068 provides overvoltage protection for line-voltage mains connections meeting both of the following conditions: 1. The HI and LO input terminals are connected to the mains under Measurement Category II conditions, defined below. 2. The mains are limited to a m ...
... In order to prevent electric shock, DM3068 provides overvoltage protection for line-voltage mains connections meeting both of the following conditions: 1. The HI and LO input terminals are connected to the mains under Measurement Category II conditions, defined below. 2. The mains are limited to a m ...
OKY T/3, T/5-W5 Series
... specifications (www.dosapower.com). Applications include powering CPU’s, datacom/telecom systems, programmable logic and mixed voltage systems. The wide input range is 2.4 to 5.5 Volts DC. Two maximum output currents are offered, 3 Amps (T/3 models) or 5 Amps (T/5 models). Based on fixed- ...
... specifications (www.dosapower.com). Applications include powering CPU’s, datacom/telecom systems, programmable logic and mixed voltage systems. The wide input range is 2.4 to 5.5 Volts DC. Two maximum output currents are offered, 3 Amps (T/3 models) or 5 Amps (T/5 models). Based on fixed- ...
LIMEL Integrated Laboratory for Electrical Machines Laboratory structure
... LIMEL, Electrical Machines Integrated Laboratory is a set of different elements that can be interconnected to form a complete learning and teaching center. From the minimum configuration to the most advanced one (always depending on the customer’s choice) EDIBON offers a means of learning electric f ...
... LIMEL, Electrical Machines Integrated Laboratory is a set of different elements that can be interconnected to form a complete learning and teaching center. From the minimum configuration to the most advanced one (always depending on the customer’s choice) EDIBON offers a means of learning electric f ...
Detailed Service Manual
... permitted levels of RF energy for the general population. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety ...
... permitted levels of RF energy for the general population. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety ...
HIMA Catalogue PES H41q and H51q
... Attention: Maintenance on supply, signal and data lines may only be executed by qualified personnel with consideration off all ESD protection measures. With direct contact of this lines the maintenance personnel have to be electrostatic discharged! ...
... Attention: Maintenance on supply, signal and data lines may only be executed by qualified personnel with consideration off all ESD protection measures. With direct contact of this lines the maintenance personnel have to be electrostatic discharged! ...
Arduino & E-Health/M
... Where( can you ) to get (obtain) Hardware & Software? (rhtaorical) How can I get? ...
... Where( can you ) to get (obtain) Hardware & Software? (rhtaorical) How can I get? ...