Download ZLM4 OEM Technical Manual Version 3, June 2014

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Islanding wikipedia , lookup

Power inverter wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Three-phase electric power wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

History of electric power transmission wikipedia , lookup

Electrical substation wikipedia , lookup

Rectifier wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Rechargeable battery wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Schmitt trigger wikipedia , lookup

Power electronics wikipedia , lookup

Distribution management system wikipedia , lookup

Voltage regulator wikipedia , lookup

Surge protector wikipedia , lookup

Opto-isolator wikipedia , lookup

Stray voltage wikipedia , lookup

Alternating current wikipedia , lookup

Power MOSFET wikipedia , lookup

Buck converter wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Voltage optimisation wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
ZLM4 OEM Technical Manual
Version 3, June 2014
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 1 of 32
Issue:1/08/2014 10:49:00 AM
Contents
INTRODUCTION ................................................................................................................................................... 4
Scope and Purpose ............................................................................................................................................ 4
DRAFT .................................................................................................................................................................. 4
Features ......................................................................................................................................................... 5
Limitations ...................................................................................................................................................... 5
Equipment Requirements and Options ................................................................................................................... 6
Requirements..................................................................................................................................................... 6
Options .............................................................................................................................................................. 6
OPERATION ......................................................................................................................................................... 7
Status LED Lights............................................................................................................................................... 7
LCD display........................................................................................................................................................ 7
ZLM4 LCD Screen.............................................................................................................................................. 8
Control Options .................................................................................................................................................. 9
Control Arbitration .............................................................................................................................................. 9
Control inputs ..................................................................................................................................................... 9
Keypad Control .................................................................................................................................................. 9
Keypad Versions .............................................................................................................................................. 10
Arming/Disarming the Fence Using the Keypad ................................................................................................ 10
Keypad Status Display ..................................................................................................................................... 10
When an Alarm Occurs .................................................................................................................................... 10
To Silence the Alarm ........................................................................................................................................ 11
To Disarm ........................................................................................................................................................ 11
To Clear Alarm Memory ................................................................................................................................... 11
Changing your User PIN................................................................................................................................... 11
Standby Battery................................................................................................................................................ 11
Internal Beeper/Keypad Beeper........................................................................................................................ 11
ZLM4 Relevant Keypad Codes ......................................................................................................................... 12
SPECIFICATIONS ........................................................................................................................................... 13
INSTALLATION ................................................................................................................................................... 14
Installation Steps .............................................................................................................................................. 14
Jumper Configuration ....................................................................................................................................... 15
Fence Terminals .............................................................................................................................................. 15
Fence Wiring Diagrams .................................................................................................................................... 17
Standalone fence continuity monitor .............................................................................................................. 17
Low Voltage Zoning System .......................................................................................................................... 18
Control, Power and IO Terminals ...................................................................................................................... 16
Wiring Diagrams............................................................................................................................................... 19
Combining the ZLM4 with a Z Series energiser ................................................................................................. 19
Fence Wiring ................................................................................................................................................ 19
Keypad Bus Wiring ....................................................................................................................................... 20
Example group wiring diagrams .................................................................................................................... 21
Z28 and two ZLM4 connected to Perimeter Patrol through a PAE223 (USB Interface) ................................... 21
PROGRAMMING OPTIONS ................................................................................................................................ 22
Enter Programming mode................................................................................................................................. 22
To exit programming mode ............................................................................................................................... 23
Changing the installer PIN ................................................................................................................................ 23
Changing an Option ......................................................................................................................................... 23
Programmable Options Table ........................................................................................................................... 24
Programming Options in Detail ......................................................................................................................... 25
Zone 1 Fence Voltage Alarm Level (01xx#) ................................................................................................... 25
Zone 2 Fence Voltage Alarm Level (02xx#) ................................................................................................... 25
Zone 3 Fence Voltage Alarm Level (03xx#) ................................................................................................... 25
Zone 4 Fence Voltage Alarm Level (04xx#) ................................................................................................... 25
Missed Pulse Count (06xx#) ......................................................................................................................... 25
Battery Alarm Voltage (07x#) ........................................................................................................................ 25
Siren on Time (08x#) .................................................................................................................................... 26
Siren Off Time (09x#) .................................................................................................................................... 26
Siren Cycles (10x#)....................................................................................................................................... 26
Input Type (11x#).......................................................................................................................................... 26
Input 2 Function (12x#) ................................................................................................................................. 26
Gate Delay (13x#)......................................................................................................................................... 27
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 2 of 32
Issue:1/08/2014 10:49:00 AM
Chime mode (14x#) ...................................................................................................................................... 27
Fence Mode (15x#) ....................................................................................................................................... 27
Binary Options (16x#) ................................................................................................................................... 27
Auto Re-Arm time (20x#) .............................................................................................................................. 27
Relay Functions ............................................................................................................................................ 29
Group Mode (26x#) ....................................................................................................................................... 30
Keypad programming........................................................................................................................................... 31
Changing the Keypad Messages and Address .................................................................................................. 31
Keys used for changing messages: ............................................................................................................... 31
To Exit Keypad Programming ........................................................................................................................... 31
Connecting Multiple Keypads to a system ......................................................................................................... 31
Notes Regarding Keypad Configuration ............................................................................................................ 32
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 3 of 32
Issue:1/08/2014 10:49:00 AM
INTRODUCTION
The ZLM4 is a 4 zone low voltage electric fence monitor. The ZLM4 may be used by itself or in conjunction with a
number of high voltage security electric fence energisers. The ZLM4 monitors up to 4 loops of fence wire, each up
to several hundred meters long, to detect someone tampering with the fence by cutting or shorting the wires.
When used in conjunction with a high voltage electric fence energiser the ZLM4 is wired to the non energised earth
wires on the fence. In this way the ZML4 can be used to split one high voltage zone into up to 4 low voltage
monitored zones for improved targeting of the response to potential security breaches.
The ZLM4 is compatible with the JVA Z series energisers. It may be connected via a Keypad bus network with
other Z series devices to enable the whole group to be controlled via one keypad, or linked to a PC running
Perimeter Patrol.
The ZLM4 monitors a low voltage loop using intrinsically safe, isolated ELV DC. It employs a continuity check for
detecting open circuits, DC voltage level sensing to detect a short to ground and pulse voltage sensing to detect a
short to a line powered by a high voltage fence energiser.
The advanced features of this device allow the performance to be tuned to the fence and to the particular
requirements of the site. This is done by adjusting the devices programmable options.
The ZLM4 will report an alarm on seeing a low voltage loop cut (open circuit), shorted to ground (short), when high
voltage from an electric fence energiser wire is shorted to the monitored low voltage loop or when two low voltage
loops short to one another (cross couple).
Scope and Purpose



This document is intended for the training of engineering and technical personnel both internally at Pakton
and for our OEM customers.
As a reference for the features and specifications per version, as such it will be kept up to date and reissued with each revision of the PCB or firmware. Please ask Pakton for the latest version.
The users / installation manual will be drawn directly from this material (reformatted). Information NOT
meant to be included to end users should be identified by an “OEM only” comment.
This manual relates to:
PCB versions:
1.00 or higher
Firmware version:
1.00 or higher (the firmware version is shown on the LCD after reset)
Current Firmware:
1.00
Latest Version
The latest version of this OEM manual should be available from here.
The latest version of the Users manual should be available from here.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 4 of 32
Issue:1/08/2014 10:49:00 AM
Features
 Monitors for continuity using safe 50V DC pulses.
 Can be used to split a single security electric fence zone into up-to 4 low voltage zones
 Can detect a short, cut or if the monitored wire is touching a high voltage wire
 Optional LCD display, displays which zone is in alarm and other information
 Controlled and Programmed via a JVA keypad with similar codes to the JVA Z series
Compatible with all JVA Z series network adaptors including :
o USB
o Able to be monitored via PC (using Perimeter Patrol software version 5.3 or above)
o RS485
o TCP/IP *not all versions
o GSM *not all versions
 Able to be integrated into third party access control and security information management systems at a
variety of levels
 Enables the construction of systems from economical Key switch operation to complex PC controlled
applications
 Built into the wall mountable Z series energiser enclosure
 Runs from 16Vac or 12V DC external source
 In built battery charger and for optional 7aH back up battery
 Siren and Strobe switched 12V DC outputs for standalone operation
 2 control inputs and 4 form C relays with many programmable functions for low level integration with other
systems
 Fence connections are fully isolated from power and IO as per relevant parts of ICE60335.2.76
Limitations







Any energiser used with the ZLM4 must comply with IEC60335.2.76 electrical safety standard
Energisers with a negative voltage pulse may not be suitable
The energiser output pulse energy must not exceed 18 Joules
The maximum series resistance of the fence wire loop which can be accurately monitored is 5000 Ohms
* Not all versions of the PAE212, PAE224 or PAE218 GSM module recognise the ZLM4. For compatibility
please check with your distributor or JVA
The JVA LCD keypad (PTE0210) requires version 2.12 or later firmware to operate with a ZLM4, the
keypad firmware can be viewed by at power up or by pressing *9# on the keypad.
Perimeter Patrol version 5.2.2 or later is required to operate with a ZLM4
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 5 of 32
Issue:1/08/2014 10:49:00 AM
Equipment Requirements and Options
Requirements


12V rechargeable backup battery or external 12V source
16Vac or 24Vdc power adaptor if using internal rechargeable battery
Options



12V Siren and strobe light
LCD Keypad (PTE0210). Note 1,2
Windows PC
o Windows XP or later
o PAE223 or PAE100 serial adaptor AND USB to serial adaptor
o or PAE212 TCP/IP adaptor
o Perimeter Patrol PC application
Notes
1. While the Keypad is not essential for normal operation, it is required to adjust the programmable options.
2. Up to 3 Keypads may be connected in parallel on a ZLM4, each Keypad must have a unique ID setting.
3. The ZLM4 contains patent pending technology, contact JVA for more information.
For more information please see www.jva-fence.com.au
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 6 of 32
Issue:1/08/2014 10:49:00 AM
OPERATION
Status LED Lights
The status LED’s on the front of the ZLM4 allow the user to quickly ascertain the current status of the unit and if
any action needs to be taken. Below is a brief description of each LED (top to bottom) and the information it
conveys.
Power
Armed
Fence
Gate
Status
-
On (Green) whenever the unit has power.
On (Red) when the unit is armed, flashes if any zone is bypassed
On (Red) when there is a fence alarm (any zone), flashes if any zone has a low voltage
On (Red) when there is a gate alarm, flashes if the gate is open
Flashes (Red) an error code for service errors. The LCD may also show an error message.
Status LED
Number of
Flashes
Interpretation
Corrective \Action
1
Not used
2
16Vac Mains fail
Restore mains power
3
Low battery, bad battery
Charge or replace battery
4
PCB service fault
Return to repair/service centre
Note: A Z slave will show this error if
disconnected from the Master
LCD display
The Optional LCD display shows the status of the ZLM4 at all times.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 7 of 32
Issue:1/08/2014 10:49:00 AM
ZLM4 LCD Screen
The ZLM4 will show the status on the optional LCD display.
When disarmed
JVA ZLM4
Disarmed
While armed, the LCD display cycles the following information.
1: 35V 2: 37V
2: 40V 4: 35V
ZLM4 Armed
All clear
Battery 14.5V
AC On
Pressing # on the keypad will freeze the current information displayed on the LCD screen for approximately 10
pulses. Pressing the # key again will cycle the display to the next information screen.
When an alarm occurs the screen will detail the type of alarm and the sector if applicable.
Alarm: Zone 1
Gnd Short
Alarm: Zone 2
Fence Cut
ALARM
Gate
ALARM
Energiser Fail
Alarm: Zone 3
HV Short
Various “troubles” are also displayed, such as AC fail or low battery.
Battery 11.5V
AC Fail
When the ZLM4 is disarmed, all current alarms are shown.
JVA ZLM4
Disarmed
Alarm: Zone 1
Gnd Short
The display also shows the programmable options and values when in programming mode.
1: Alarm V 1
Value: 20
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 8 of 32
Issue:1/08/2014 10:49:00 AM
Control Options
The ZLM4 may be armed and disarmed (controlled) using a:
 Magnetic proximity fob
 Key switch or remote switch connected to the control input (IN1)
 Remote control radio receiver connected to IN1
 Z Series Keypad (LCD or Touch)
 JVA Webserver *not all versions
 JVA GSM module *not all versions
 Windows PC running JVA Perimeter Patrol
 Low level interface (wired to control inputs and relay outputs) from a third part security alarm panel or
Physical Security Information System (PSIM)
Note: More than 1 method may be used in the one installation.
Control Arbitration
If an installation contains two ways to control the ZLM4, then the most recent control signal will determine the
Armed/Disarmed state. For example if the ZLM4 is armed via the keypad and then disarmed at the control input
(IN1) it will disarm.
The higher level control methods such as the Webserver, GSM and PC control software may override the Control
input and Keypads methods, depending on the options used. If you need to make sure that fence is disarmed (for
maintenance) then using the Key switch or keypad alone may not guarantee that the fence will remain disarmed.
Magnetic proximity switch
The ZLM4 may be controlled using the JVA permanent magnet key ring fob. To operate the fob must be held
against the control zone marked on the front label. The energiser will beep and toggle from armed to disarmed or
visa versa after the fob is held in position for 2 seconds. The magnetic proximity receiver should be disabled in the
programmable options if it is not being used.
Control inputs
The ZLM4 may have a single Key switch mounted on the right hand side of the cabinet which may be used to arm
and disarm the security electric fence to which it is connected. This switch is useful for the simplest
implementations where no keypad or PC control program is used. It may be disabled by the installer, by removing
the lead from socket J2.
When switched on via the Key switch (or a switch connected to IN1) the ZLM4 will power up the energiser it is
coupled to and begin monitoring the fence.
The screen will change to display the Armed status and any faults or alarms. If there is a fence fault the ZLM4 will
go into alarm, the internal beeper will sound (if it has not been inhibited) and any siren and strobe connected to the
ZLM4 will be turned on.
The zone in which the fault has occurred will be displayed.
Switching the Key switch off will disarm the ZLM4, though it will continue to display the last alarm and zone.
Keypad Control
The ZLM4 uses the same keypad as the Z series
energisers and is controlled using similar keypad codes.
The PTE0210 keypad (Version 2.00 and higher) will
display the Fence voltages plus the zone if in fence
alarm.
Alarms and troubles will also be displayed.
The Keypad has two LED lights
Power
Armed
On with Mains power, Off with Main
fail, flashes on low battery
On when the energiser is armed,
flashes when in low power mode
All other indication is given via messages on the keypad
LCD screen.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 9 of 32
Issue:1/08/2014 10:49:00 AM
If the Keypad shows “Alarm” or “Trouble” pressing [#] will reveal more information about the problem.
NOTE: There is no panic function currently implemented.
Keypad Versions
The current version keypad is a PTE0210 with code version 2.00. Older versions have limitations.
The keypad version can be seen by pressing *9#.
PTE0200



PTE0210




PTE0230



Shows “ALPHA KEYPAD Revision 7.0”
Cannot show Zone (fence) voltages
Shows only Zone alarms 1-8
Does not show Gate alarms
Shows “PTE0210” and the code version.
Can show fence voltages
Will respond to *68# to analyse the “group”.
Version 1.21 and below
o Older version, can be upgraded to V2.00 firmware.
o Cannot detect or operate with the ZLM4.
Version 2.20 and higher
o ZLM4 is supported, zones are displayed.
Android based touch screen keypad
Provides the most advanced monitoring and control of all Z range devices
All functions are available
Refer to the inbuilt help, the rest of this chapter refers to the simpler LCD keypads above.
Arming/Disarming the Fence Using the Keypad
Enter your User PIN (Personal Identification Number: four digits long) and push the # key. Make sure the red ARM
light comes on and the keypad beeps twice to confirm that the system is armed.
The fence will power up and if all is well (no faults) the system will be ready to deter and detect.
To disarm the system enter your User PIN and press #.
Note: If there is an alarm sounding you will need to enter your PIN twice, once to silence the alarm and once more
to disarm.
See also the section on programming Keypads.
Keypad Status Display
In normal operation the keypad shows a continuous summary of the system status. For example if the system is
disarmed the keypad will display “Ready to Arm”.
If the system is armed then the keypad will display the voltages for each zone in the system.
Since there can be many things to display the keypad automatically “scrolls” through all relevant detail. Each
screen is show for about 2 seconds. If you wish to hold the display at a particular point simple press the [#] key.
The auto scrolling will stop for about 20 seconds.
Pressing the [#] key again will advance the display one step.
If a new trouble (AC fail, low battery etc) or alarm occurs, the keypad screen will jump to the relevant zone, the
keypad will beep (unless toggled off) and auto scrolling will cease for about 3 minutes.
When an Alarm Occurs
An Alarm will occur if there is a fault on the fence caused by a short or an open circuit (cut), while the system is
armed. The siren will sound and the strobe will light. The internal beeper and the Keypad may also sound,
depending on how your system is configured.
There are 3 ways the ZLM4 can detect a fence fault:
1) A low voltage circuit is cut (open circuit)
2) A low voltage circuit is shorted to ground (LV short)
3) A high voltage wire shorts to a low voltage wire (HV Short)
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 10 of 32
Issue:1/08/2014 10:49:00 AM
The siren and keypad beeper will sound and any relays assigned to this fence alarm will turn on.
An alarm will also sound if Control Input 2 is assigned to the “gate” function and the gate input is opened for longer
than the Gate delay time.
After the siren has cycled on and off according to the times and numbers set in options, the siren will stop
sounding. The on and off timing can be set in the programmable options. The Strobe will remain on. After a further
delay (Auto Rearm Time) the siren will again respond to the next alarm condition with a new set of on / off cycles.
If the alarm condition is removed, the siren will stop after the end of the current “on” time (Siren On Time).
If the siren is silenced (by entering PIN#) then the siren will enter the next “off” cycle (Siren Off Time). If the alarm
condition is still present (voltage is low) the siren will sound again after the preset “off” time. If the alarm condition is
not present the Energiser is instantly rearmed, irrespective of the auto-rearm setting.
To Silence the Alarm
If there is no Keypad attached simply disarm the ZLM4 using the Key switch or magnetic fob.
Using a Keypad, enter your User PIN and press #. This will silence the alarm but not disarm the system; the armed
light will still be on. The system will be ready for the next alarm.
Note: This silence function will not operate if the ZLM4 is part of a Z series “group”.
The last alarmed Zone will still be displayed on the front panel LCD and the Keypad.
The siren and strobe are ready to respond again if triggered.
To Disarm
If there is no Keypad attached simply disarm the ZLM4 using the Key switch or magnetic fob.
Using a Keypad, disarm the system by entering your User PIN and press #.
The Fence or Gate light on the ZLM4 will remain on to show the Alarm memory. This can be cleared by entering
the Clear Alarm memory command *1#. The Alarm memory will also be cleared when the ZLM4 next Arms.
To Clear Alarm Memory
After an alarm occurs, pressing *1#, will clear the alarm memory. If the problem still exists the unit will alarm again.
Changing your User PIN
Enter the current 4 digit PIN and press *0#. This enters User Programming mode.
Enter your new PIN (must be 4 digits) and then #.
Press *# to exit User Programming mode.
Make sure your new PIN works by using it to arm the energiser.
The default User PIN is 1234.
For example, the following Keypad sequence will change the User PIN to 8015 from the default PIN:
1234*0#8015#*#
Standby Battery
Should there be a loss of mains power, the Power light on the keypad will go off. The status LED on the ZLM4 front
panel will flash twice and the Keypad will show Trouble – AC Fail.
If the loss of power is prolonged, the battery may become discharged and become ineffective. The Power light on
the keypad will start to flash indicating that the battery charge is low. The status LED on the ZLM4 front panel will
flash three times and the Keypad will show TROUBLE: LOW BAT
If the standby battery requires replacement, the Status LED on the Energiser will flash 3 times even after the mains
power has been restored.
Internal Beeper/Keypad Beeper
Depending on the Chime Mode setting, the internal beeper and keypad beeper will sound when there is a fence
alarm, a gate alarm, a general alarm or a door chime. On flat battery the keypad will always beep 4 times before
the energiser automatically enters low power mode to preserve the battery. On AC Fail it will not beep.
Note: The Internal beeper also beeps at Power up.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 11 of 32
Issue:1/08/2014 10:49:00 AM
ZLM4 Relevant Keypad Codes
Function
Arm/Disarm
Silence an alarm (Single zone system only)
Start Programming the Z series energiser
Start Programming the Keypad
Exit Programming (any mode)
Change a User PIN
Change the Installer PIN
Arm All Zones (Multi-zone groups)
Arm Zone 1 (Master)
Arm HV Zone x, where x is any zone number up to 15
Disarm All Zones
Disarm HV Zone 1 or Master
Disarm HV Zone x, where x is any zone number up to
15 (Note 1)
Arm Gate circuits only
To change the Keypad Messages to English
To change the Keypad Messages to Spanish
Keypad Audible Feedback Toggle
Keypad Chimes Toggle On/Off
Keypad Error Tones Toggle On/Off
Keypad Alarm Tones Toggle On/Off
Backlight Toggle On/Off
Display Keypad Model
Analyse Group
Reset and Display firmware version number
Reset and return to factory defaults
Siren test
Battery test
Key Sequence
[User PIN][#]
[User PIN][#]
[Installer PIN][*] [0] [#]
[Installer PIN][*] [0] [1] [#]
[*] [#]
[User PIN][*][0][#][New PIN]#
[0] [0] [New Installer PIN][#]
[User PIN][*][1][0][#]
[User PIN][*][1][1][#]
[User PIN][*][1][x][#]
[User PIN][*][2][0][#]
[User PIN][*][2][1][#]
[User PIN][*][2][x][#]
Clear Alarm memory
[*] [1] [#]
© JVA Technologies Pty Ltd
OEM technical manual.docx
[User PIN][*][4][#]
[*][3][1][#]
[*][3][2][#] (not well supported yet)
[*] [5] [1] [#]
[*] [5] [3] [#]
[*] [5] [4] [#]
[*] [5] [5] [#]
[*] [8] [#]
[*] [9] [#]
[*][6][8][#]
[User PIN][*][6][8][#]
[Installer PIN][*] [6] [8] [#]
[*] [6] [3] [#]
[*] [6] [4] [#]
Page 12 of 32
Issue:1/08/2014 10:49:00 AM
SPECIFICATIONS
The specifications table below outlines the power consumption of the ZLM4 and the acceptable voltage and current
ranges for different inputs and outputs.
Internal battery charger float voltage
Internal battery charger charging current
Power consumption of ZLM4 (Note 1)
Maximum AC input voltage when internal battery charger is supplying 580mA
Battery backup time (without keypad)
Maximum voltage on “In1”, “SW2” and “Gate” inputs (Note 2)
Maximum power provided to “Siren” and “Strobe” outputs (Note 3)
Maximum Energiser Joules (Note 4)
Maximum low voltage loop impedance
Maximum loop capacitance to ground
14.2Vdc
1200mA
130mA at 12.5
Vdc
19Vac
24 Hours
5Vdc
35Watts (2.5A at
13.5V)
18J
5000 Ohm
0.2uF
Note 1: This is the power consumption when none of the powered outputs are active and the keypad is not
connected. The rated power consumption may be lower depending on relay configuration and alarm states.
Note 2: The control inputs as supplied with 5V from a “weak pull up” circuit so that they can be controlled using dry
contacts from a relay or switch. A device with “open collector” outputs may be used. They can also be driven from a
5V switched output, so long as the driving circuit actively pulls down to ground when off.
Note 3: This is the limit for the combination of the loads on both the “Siren” and “Strobe” outputs.
Note 4: This is the maximum rating of the energiser if the ZLM4 is used on the same fence as a high voltage
electric fence energiser. Beyond this rating the ZLM4 loop circuit protection MOV’s may fail if high voltage wires are
shorted to the ZLM4 loop wires.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 13 of 32
Issue:1/08/2014 10:49:00 AM
INSTALLATION
It is recommended that all installations are performed by qualified technicians.
Installation Steps
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
Read the entire ZLM4 and Energiser manuals first!
Design and build the fence. (Beyond the scope of this manual.) Ask your distributor for help if required.
Decide where the energiser, ZLM4 and Keypad are to be mounted. If on an external wall it should be
housed within a weatherproof equipment box, shaded from direct sun.
Remove the lid of the ZLM4 using a 5mm Hex key.
Remove the ZLM4 PCB chassis from the housing by removing the two screws at the top corners.
Mount the housing by using 4 screws through the rear of the box. The box must be mounted to a wall
in such a way that all of the 4 holes in the rear of the case are against the mounting surface.
Replace the PCB chassis.
If using a keypad, remove the rear housing of the keypad and fix it to the wall.
Wire the low voltage cables to the PCB terminals.
Wire the high voltage cable to the PCB terminals.
Set the Jumpers as required
Fit the battery leads to the battery. The Error LED should be blinking twice to show mains fail.
Replace the front cover (lid).
Turn AC power on.
Arm the ZLM4 and Switch on the Energiser if used. The LCD display will now show the zone voltages.
Find and remove any faults on the fence
Test that a short in any zone puts the ZLM4 into alarm and shows the correct Zone
Notes:
1.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 14 of 32
Issue:1/08/2014 10:49:00 AM
Jumper Configuration
The ZLM4 is equipped with three jumpers, two of which (J3 and J4) operate in an identical fashion to those on the
Z14. The third jumper, J8 will suppress the beeper on the ZLM4 when fitted.
These are located in the top left corner of the PCB.
Jumper
J3
Function
Inhibit Mains fail error.
J4
Factory default jumper
Off to return programmable options to
factory defaults on power up.
J8
Inhibit internal Beeper
Purpose
J3 is fitted to inhibit Mains fail errors if the
intention is to operate the energiser on DC
only (as in solar power systems).
If the energiser needs to be defaulted to
factory settings, remove all power (AC and
battery) and remove the J4 jumper. Reapply
the mains and the battery power. Reapply the
J4 jumper and the Energiser will be reset to
default settings.
Fitted to inhibit the internal beeper,
irrespective of any option setting.
Fence Terminals
Description of fence terminals (Left to Right)
Loop 1
Loop 2
Loop 3
Loop 4
Ground
© JVA Technologies Pty Ltd
OEM technical manual.docx
Connect to zone 1 fence wires
Connect to zone 2 fence wires
Connect to zone 3 fence wires
Connect to zone 4 fence wires
Connect to main fence earth stakes.
Page 15 of 32
Issue:1/08/2014 10:49:00 AM
Control, Power and IO Terminals
Label
Type
Description
IN1
2 Way
Gate
2 Way
Keypad
3 Way
Siren
2 Way
Strobe
2 Way
AC IN
3 Way
Relay 3
Relay 4
Relay 5
Relay 6
3 Way
3 Way
3 Way
3 Way
Energiser control input (dry contact). Defaults to normally open.
Can be used for a remote switch or a radio receiver. The receiver may be powered
from the keypad +12V terminal.
Energiser control input, defaults to normally open low power but may also be
assigned to gate input. When the unit is armed and the gate is opened, it will trigger
the gate alarm.
Supplies power and data line for an external keypad. The +12V source on these
terminals is protected with 1A self resetting fuse.
Switched 12 volt output. Low side switched. 35W max (including strobe). A buffer
relay should be used when connecting these outputs to an alarm panel.
Switched 12 volt output. Low side switched. 35W max (including siren). A buffer
relay should be used when connecting these outputs to an alarm panel.
16Vac power input. Fused via F3 3A self resetting fuse.
The Earth terminal may be required to be connected to mains earth in some
countries, consult your local wiring guidelines.
May be set to any of 16 alarm conditions. Defaults to zone 1 alarm.
May be set to any of 16 alarm conditions. Defaults to zone 2 alarm.
May be set to any of 16 alarm conditions. Defaults to zone 3 alarm.
May be set to any of 16 alarm conditions. Defaults to zone 4 alarm.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 16 of 32
Issue:1/08/2014 10:49:00 AM
Fence Wiring Diagrams
Standalone fence continuity monitor
The ZLM4 may be used to monitor a loop of wire on or under a perimeter fence.
 Bare conductors on insulators as per high voltage electric fence, but powered by the ZLM4 low voltage
monitor for sensitive environments such as public areas.

Insulated wire woven through balustrade or chainmesh fencing. The alarm is given if the insulated wire is
cut or shorted to earthed metal.

Insulated wire buried underground. The alarm is given if the insulated wire is cut or shorted to earth.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 17 of 32
Issue:1/08/2014 10:49:00 AM
Low Voltage Zoning System
The ZLM4 uses interleaved low voltage wires of the fence to detect any tampering.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 18 of 32
Issue:1/08/2014 10:49:00 AM
Wiring Diagrams
Combining the ZLM4 with a Z Series energiser
A ZLM4 can be combined with JVA Z series energisers to power the fence. The ZLM4 should be configured as a
slave and the Z series energiser as the master. The number of Z series energisers and ZLM4 is limited by the
available ID numbers if using the keypad bus, it is unlimited if using TCP/IP.
Fence Wiring
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 19 of 32
Issue:1/08/2014 10:49:00 AM
Keypad Bus Wiring


Set the Group ID of the Z18 to Master (2601#)
Set the Group ID of the ZLM4 to Slave 1 (2602#)
The Group ID of the ZLM4 must be 1 value higher than the Group ID of the Z-Series Energiser driving it
A ZLM4 by itself does not require the Group ID to be configured as it is factory set to Stand-Alone mode
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 20 of 32
Issue:1/08/2014 10:49:00 AM
Example group wiring diagrams
Z28 and two ZLM4 connected to Perimeter Patrol through a PAE223 (USB Interface)
(Change diagram to one Z28 and two ZLM4)



Set the Group ID of the Z28 to Master (2601#)
Set the Group ID of the first ZLM4 to Slave 1 (2602#)
Set the Group ID of the first ZLM4 to Slave 2 (2603#)
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 21 of 32
Issue:1/08/2014 10:49:00 AM
PROGRAMMING OPTIONS
Like the Z series of security energisers, the ZLM4 has non-volatile memory in which programming options (or setup
parameters) can be stored. These are factory pre-set (defaults), but can be field programmed using a keypad.
Enter Programming mode
To enter programming mode, enter the 6 digit installer PIN followed by *0# keys. The keypad will beep twice to
indicate that the command was accepted. If the PIN was incorrect the keypad will beep 3 times. The LCD on the
ZLM4 will now show the first programming option and its current setting.
Pressing the # key will cycle through all the options on the LCD.
Note: Not all numbers are used.
The Default Installer PIN is 012345
Also see a table of
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 22 of 32
Issue:1/08/2014 10:49:00 AM
ZLM4 Relevant Keypad Codes which are in the Operation section of this manual.
To exit programming mode
To exit programming mode press *#. If left unattended the ZLM4 will time out and auto exit after approximately 5
minutes.
Changing the installer PIN
The installer PIN may only be changed while in programming mode.
To enter a new installer pin, press 00 followed by the new 6 digit PIN, then the # key.
If you cannot remember your installer or user PIN, return the ZLM4 memory to default. To do this, remove power
(AC off and disconnect the battery), open the ZLM4 enclosure, remove jumper J4 and reconnect the battery for
about 10 seconds. Do not forget to re-fit J4.
This will return all options to the factory set defaults.
Changing an Option
The options have possible values in the range of 0 to 99, some are limited to lower maximum values.
To change an option value, first check the option number (see table below) and then the table of values for that
option. On the Keypad, press the option number followed by the required value.
For example, to change option 1 to the maximum press 0199#, the keypad will beep twice to indicate that the
command was successful. The Energiser LCD will immediately show the updated value.
As the keypad bus is common to a group of Z-Series Energisers and ZLM4s, one keypad could be used to program
all connected units at the same time. A Group containing Z-Series Energisers and ZLM4s MUST NOT get
programmed this way as the ZLM4 contains different Option values to the Z-Series Energisers. Each
ZLM4/Energiser will need to be isolated from the Group Wiring and programmed individually.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 23 of 32
Issue:1/08/2014 10:49:00 AM
Programmable Options Table
Option
01
Function
Voltage alarm
level zone 1
Default
20V
02
Voltage alarm
level zone 2
Voltage alarm
level zone 3
Voltage alarm
level zone 4
20V
Description
Sets the voltage below which the fence alarm will occur. If the
return voltage falls below this level for more than the Missed
pulse count a fence alarm (zone 1) will occur.
As above
20V
As above
20V
As above
Not used
Missed Pulse
Count
Battery Alarm
Voltage
0
3
08
Siren On Time
4 (3 Mins)
09
Siren Off Time
4 (10 Min)
10
Siren Cycles
3
11
Input type
0 (N/O)
12
13
14
15
16
17
18
19
20
Input 2 Function
Gate Delay
Chime Mode
Not Used
Binary Options
Not Used
Not Used
Not used
Auto Rearm
Time
0
2 (1 Min)
2 (siren)
0
0
0
4
0
0
21
22
23
24
25
26
27
Relay 1
Relay 2
Relay 3
Relay 4
Relay 5
Group ID
Relay 6
8
9
03
04
05
06
07
© JVA Technologies Pty Ltd
OEM technical manual.docx
2 (10V)
0
Sets the number of pulses which may be missed before the
alarm is activated
Sets the battery voltage threshold below which the general
alarm will activate
Sets the time that the siren (and keypad beeper) will stay on
after an alarm
The amount of time the siren will be off for after the on time
has expired
The number of times the siren will sound for the time set in on
time above. After this many cycles the siren will automatically
mute
Allows the control inputs to be changed from normally open to
normally closed.
Gate switch
Gate switch open time till alarm
Allows the keypad and internal beeper function to be altered
Miscellaneous options
Sets the time which must elapse after an alarm has timed out
(completed the siren cycles) before the unit will automatically
re-arm ready for the next alarm event.
Used to assign an alarm function to relay 1 (siren output)
Used to assign an alarm function to relay 2 (strobe output)
Used to assign an alarm function to relay 3 (Zone 1 alarm)
Used to assign an alarm function to relay 4 (Zone 2 alarm)
Used to assign an alarm function to relay 5 (Zone 3 alarm)
If used as part of a group, this sets the device ID
Used to assign an alarm function to relay 6 (Zone 4 alarm)
Page 24 of 32
Issue:1/08/2014 10:49:00 AM
Programming Options in Detail
Zone 1 Fence Voltage Alarm Level (01xx#)
Sets the voltage below which the zone alarm will occur. If the fence voltage
measured at the return “R” loop terminal falls below this level for more than the
Missed pulse count a fence alarm (zone 1) will occur. The value is set directly,
not via a table.
For example to set a threshold of 25V enter: 0 1 2 5 #
Setting this option to 0 effectively turns off fence voltage monitoring.
Value (x)
Minimum
0
Default
20
Maximum
40
Alarm Level
0.0 V
20V
40 V
Warning: Setting this level to higher than the normal running voltage of the fence
will result in continuous fence alarms.
Zone 2 Fence Voltage Alarm Level (02xx#)
As above for zone 1.
Zone 3 Fence Voltage Alarm Level (03xx#)
As above for zone 1.
Zone 4 Fence Voltage Alarm Level (04xx#)
As above for zone 1.
Missed Pulse Count (06xx#)
Value (x)
This option enables the pulse count to be varied from the default (3). This is the
number of bad or missing pulses that are counted before the alarm occurs. Note:
The lower this option is set the more likely you are to get false alarms.
The value is set directly. For example to set a threshold of 2 bad or missing
pulses enter: 0 6 0 2 #.
0
1
2
3
4
5
6
7
8
9
Missed Pulses
1
1
2
3
4
5
6
7
8
9
Battery Alarm Voltage (07x#)
This option sets the battery voltage threshold below which the general
alarm will activate. The default Battery Alarm Voltage is 10.0 Volts. This
alarm can be set to activate one of the relays, and is part of the General
alarm.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 25 of 32
Value
0
1
2
3
4
5
6
7
8
9
Alarm
9.0 V
9.5 V
10.0 V
10.5 V
11.0 V
11.5 V
12.0 V
12.5 V
13.0 V
13.5 V
Issue:1/08/2014 10:49:00 AM
Siren on Time (08x#)
This option sets the duration of time that the siren will remain on after a fence
alarm occurs. After this time the siren will turn off for the Siren Off Time indicated
in the table. The siren will sound again if the alarm is still present after this off
time has passed.
The default is 3 Minutes. This may be the subject of local regulations to
stop an alarm causing undue disturbance to neighbours, etc.
Note: the Siren On Time will be cut short if the battery falls below the low
battery level
Siren Off Time (09x#)
This option sets the amount of time the siren will be off for after the Siren On
Time has expired. If an alarm is still present after this off time the siren will sound
again.
Value
Time
10 Seconds
30 Seconds
1 Minute
2 Minutes
3 Minutes
4 Minutes
5 Minutes
6 Minutes
7 Minutes
8 Minutes
Value
Time
10 Seconds
1 Minute
2 Minute
5 Minutes
10 Minutes
20 Minutes
30 Minutes
40 Minutes
50 Minutes
60 Minutes
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
Siren Cycles (10x#)
This option sets the maximum number of times the siren will sound for the “on
time” if the alarm continues. This may be limited by local regulations to stop an
alarm causing undue disturbance to neighbours etc.
Note: This is the maximum number of cycles for 1 continuous alarm, intermittent
alarm events could cause more than this number of siren soundings.
The value is set directly. For example to 2 siren cycles enter: 1 0 2 #.
The default is 3, minimum is 1 and the maximum is 9.
Value
0
1
2
3
4
5
6
7
8
9
Cycles
1
1
2
3
4
5
6
7
8
9
Input Type (11x#)
The control inputs can be inverted.
Unless an input is used for a Gate switch, in which case it is always NC.
Value (x)
0
1
Input type
NO Normally
open
NC Normally
Closed
Input 2 Function (12x#)
This input cannot be configured to anything other than a ‘Gate’ input at this time.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 26 of 32
Issue:1/08/2014 10:49:00 AM
Gate Delay (13x#)
The gate switch must remain open for longer than the Gate Entry/Exit
Delay before the Gate Alarm is triggered. If the switch closes within this
time, the Gate timer is reset to the Gate Entry/Exit Delay value.
Value
Time
0 Seconds
(immediate)
30 Seconds
1 Minute
2 Minutes
3 Minutes
4 Minutes
5 Minutes
6 Minutes
7 Minutes
8 Minutes
Value
Function
None
Door Chime
Siren
Fence Alarm
Gate beeps
plus Siren
0
1
2
3
4
5
6
7
8
9
Chime mode (14x#)
This option allows the ZLM4 internal beeper and the keypad beeper to be used
as a door chime for the gate switch.
When set to None, the keypad beeper is used to indicate correct keypad
operation only.
When set to Door Chime, the beepers will sound when the gate switch opens,
even if the energiser is disarmed. Note “Gate” must be selected in Input 2
0
1
2
3
4
Function (Option 12).
If set to Siren, the beepers mimic the siren function.
Gate Beeps plus Siren will give 2 beeps on Gate open and 4 on close, plus
continuous for an alarm. Beeps are on Keypad only, not internal beeper.
Fence Mode (15x#)
Not currently implemented, for future use.
Binary Options (16x#)
Each option in this table can be turned on by adding the value.
For option+ 1 set 16 to 01, for + 1 and +2 set 16 to 03.
Value
0
+1
+1: Enable Siren Acknowledge. The siren will chirp once for armed and
twice for disarmed.
+2
Function
None
Disable prox
switch
Siren codes
+2 Enable Siren Acknowledge. The siren will chirp once for armed and
twice for disarmed.
Zones (not yet implemented)
This Option sets the amount of Zones the ZLM4 will monitor. This will reduce the
amount of unnecessary information that will be displayed if you are only
monitoring one zone.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 27 of 32
Value
0
1
2
3
4
Function
None
One Zone
Two Zones
Three Zones
Four Zones
Issue:1/08/2014 10:49:00 AM
Auto Re-Arm time (20x#)
This option sets the time which must elapse before another alarm will
sound after the first alarm has timed out (gone completely through its
cycles).
If an event occurs which triggers the siren, any other events which would
otherwise trigger the siren (such as a gate alarm) will be ignored while the siren
is sounding and until after the Auto re-arm time has passed.
A setting of 9 will disable auto re-arm.
The default is 0 Seconds (Immediate).
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 28 of 32
Value
0
1
2
3
4
5
6
7
8
9
Function
0 Seconds
(Immediate)
30 Seconds
1 Minutes
2 Minutes
3 Minutes
4 Minutes
5 Minutes
6 Minutes
7 Minutes
Disabled –
Do not auto
rearm
Issue:1/08/2014 10:49:00 AM
Relay Functions
All relays can be set to any of the available functions (user assignable).
Relay 1 is (21x#)
Relay 2 is (22x#) etc
NOTE:
Relay 6 is (27x#)
Defaults for the ZLM4
 Relay 1 – Siren
(8)
 Relay 2 – Strobe
(9)
 Relay 3 – Zone 1 Alarm (0)
 Relay 4 – Zone 2
(1)
 Relay 5 – Zone 3
(2)
 Relay 6 – Zone 4
(3)
Note:
1. The siren and strobe switched 12V outputs can be used to drive
external buffer relays.
Value
(x)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Mode
Zone 1 alarm
Zone 2 alarm
Zone 3 alarm
Zone 4 alarm
Armed
Un-used
Un-used
General
Siren
Strobe
AC Fail
Low / Bad Battery
Un-used
Un-used
Gate Alarm
Siren caused by Gate
Alarm
Function
Zone x
Alarm
Logic for alarm state (opposite of normal state)
The ZLM4 is Armed AND
Any zone alarm occurs, these include:
The loop return Voltage has fallen below the Fence Voltage Alarm Level (Low Voltage)
High voltage has been detected (shorted to high voltage wires)
for more Energiser pulses than the Missed Pulse Count setting. Not latched.
Armed
General
The ZLM4 is Armed
AC Fail OR Tamper OR Low Battery OR Gate Alarm OR Internal Error. Latched for internal errors
only.
Fence Alarm OR Gate Alarm OR Tamper. This will time out after the Siren Time Out time. This
function is latched.
As per Siren but does not time out, will remain on until both channels are switched off. This function
is latched.
Alarm on AC Fail. Note Jumper J3 must be removed for this feature to be enabled.
Alarm on low or bad battery
Siren
Strobe
AC Fail
Battery
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 29 of 32
Issue:1/08/2014 10:49:00 AM
Group Mode (26x#)
A group must have only 1 master. The other Energisers/Monitors in the
group are slaves.
The correct procedure is:
Connect the keypad to each Energiser/ZLM4 in turn, programming each Option
as required before linking the Keypad bus into a group.
The ZLM4 should only be a group master if there are no Z energisers in the
group. I.e. the group is made up of one or more ZLM4’s only.
If a PAE212 TCP/IP adaptor is used, it is the group master. All other devices
should be set to slaves.
All energisers must be synchronised, therefore non-synchronised agricultural
energiser must never be used in a system with a ZLM4. This allows the ZLM4
pulses to be synchronised with other ZML4s or Z-Series Energiser.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 30 of 32
Value (x)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Mode
No Group
Master
Slave 1
Slave 2
Slave 3
Slave 4
Slave 5
Slave 6
Slave 7
Slave 8
Slave 9
Slave 10
Slave 11
Slave 12
Slave 13
Slave 14
Issue:1/08/2014 10:49:00 AM
Keypad programming
Changing the Keypad Messages and Address
The messages and each of the 15 zone labels can be changed.
The Dealer Message displays when the system is on standby.
Zone Labels display after the [#] key is pressed during alarm memory or faults.
The programmable Service Message is displayed during AC failure, communication failure, or low battery.
Keys used for changing messages:
[1]
[2] Character up
[3] not used
Emergency not used
[4] <- Cursor left
[5] Next Message
[6] -> Cursor right
Fire not used
[7]
[8] Character down
[9]
Panic not used
[*]
[0] Last Message
[#] Enter / Exit
Bypass not used
To activate the keypad programming mode, enter the [Installer's Code] [*][0][1][#]. Information may be entered into
the keypad in the form of letters (upper and lower case), numbers (0 - 9), and 22 special symbols. All characters
are displayed in the order: upper and lower case letters, numbers, and special symbols. The [Space] character
precedes the letter A.
To enter a Label, use the [2] key to scroll through the characters until you reach the desired character. If you scroll
past the desired character, the [8] key may be used to scroll backwards. Note; the space character is before the A
character (When A is displayed, press [8] to get a space).
When the desired character is displayed, press the [6] key to move the cursor to the next character position. The
[4] key moves the cursor to the left.
When all characters have been entered, press the [#] key to enter the message and move to the next message
position.
Use the [0] key to move backward through the messages.
NOTE: If you move to the next message using [5] instead of the [#] key you will lose any changes you made!
To change the keypad address, scroll through the messages until the keypad displays: “Keypad address __” then
change the value by pressing [2] (up) or [8] (down). Validate by pressing [#].
The message order is:
•
SERVICE MESSAGE (Displayed under “SYSTEM TROUBLE”)
•
DEALER MESSAGE (Displayed under the standby message: “READY TO ARM”)
•
ZONE NAMES
•
BAUD RATE (should be left at 2400)
•
KEYPAD ADDRESS (should be left at 1)
To Exit Keypad Programming
When you have finished programming, press [*] [#].
Note: The keypad will also exit the programming mode if you do not press any key within a five minute period.
emergency button during power up. This feature
To return the Keypad to default settings press the
was added in keypad firmware version 1.2.
Connecting Multiple Keypads to a system
Up to three keypads may be used to remotely monitor and control the Z series security energisers.
To operate correctly, each Keypad must be configured to use a unique KEYPAD ADDRESS. This is best achieved
by connecting one keypad (at a time) to the Master Energiser and updating the KEYPAD ADDRESS. Once all
Keypads have a different address, all can be connected to the system. A recommendation is that one Keypad is
kept at ADDRESS 1.
The Energiser now needs to be introduced to all of these Keypads. This is achieved by resetting the Energiser
using the Keypad (configured to ADDRESS 1), by pressing [USER PIN]*68#. Alternately the power can also be
removed to reset the Energiser. After a reset, the Energiser will determine what Keypads are connected, and only
these ADDRESSES will be used in the future. This prevents un-authorised Keypads being added to the system
once it is running.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 31 of 32
Issue:1/08/2014 10:49:00 AM
If the security system is to use a PC based interface such as Perimeter Patrol, KEYPAD ADDRESS 2 should not
be used by a keypad. The PC software uses this address to control the Energisers.
Notes Regarding Keypad Configuration
Zone 1 (the master) must be connected to the group. If it is not connected the other energisers in the group will not
send status packets to the keypad. The status packets contain voltage and alarm information which the keypad
displays. If Zone 1 is not connected, the keypad will report a communications failure with all the zones.
A Slave Energiser disconnected from the Group will only talk to a Keypad if it has a KEYPAD ADDRESS of 1.
When adding/removing an energiser to/from the group, be sure to re-analyse the group using the key sequence
*68#. Zone 1 (the master) must be connected to the group for this operation to work.
When re-analysing a group ensure all energisers are disarmed. If they are not this function will not work properly.
Note: If the group ID has recently been changed you may need to reset ([PIN]*68#) before the new ID’s will be
properly reported to the keypad.
© JVA Technologies Pty Ltd
OEM technical manual.docx
Page 32 of 32
Issue:1/08/2014 10:49:00 AM