Monolithic Amplifier
... A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Cir ...
... A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Cir ...
N1224 TG0045A.indd
... N1224 28 V 260 A/14 V 140 A dual voltage alternator is internally rectified. All windings and currentconducting components are non-moving, so there are no brushes or slip rings to wear out. Energize switch (commonly an oil pressure switch or ignition switch) activates regulator. Field coil is then e ...
... N1224 28 V 260 A/14 V 140 A dual voltage alternator is internally rectified. All windings and currentconducting components are non-moving, so there are no brushes or slip rings to wear out. Energize switch (commonly an oil pressure switch or ignition switch) activates regulator. Field coil is then e ...
AL8806Q Description Pin Assignments
... LED current can be adjusted digitally, by applying a low frequency Pulse Width Modulated (PWM) logic signal to the CTRL pin to turn the device on and off. This will produce an average output current proportional to the duty cycle of the control signal. In particular, a PWM signal with a max resoluti ...
... LED current can be adjusted digitally, by applying a low frequency Pulse Width Modulated (PWM) logic signal to the CTRL pin to turn the device on and off. This will produce an average output current proportional to the duty cycle of the control signal. In particular, a PWM signal with a max resoluti ...
Minimum Reactive Power Filter Design for High - PPGEE
... results confirm that it is possible to achieve high power factor operation with low harmonic distortion and satisfactory system performance under very low switching frequency conditions. II. SELECTIVE HARMONIC ELIMINATION. The power circuits in this paper consist of a Neutral Point Clamped-NPC conve ...
... results confirm that it is possible to achieve high power factor operation with low harmonic distortion and satisfactory system performance under very low switching frequency conditions. II. SELECTIVE HARMONIC ELIMINATION. The power circuits in this paper consist of a Neutral Point Clamped-NPC conve ...
Cascadable Amplifier 10 kHz to 2500 MHz
... The A3010 RF amplifier is a discrete hybrid design, which uses thin film manufacturing processes for accurate performance and high reliability. This single stage GaAs FET feedback amplifier design displays impressive performance characteristics over a broadband frequency range. An RF choke is used f ...
... The A3010 RF amplifier is a discrete hybrid design, which uses thin film manufacturing processes for accurate performance and high reliability. This single stage GaAs FET feedback amplifier design displays impressive performance characteristics over a broadband frequency range. An RF choke is used f ...
TPS63700 数据资料 dataSheet 下载
... The converter operates in a fixed-frequency, pulse-width-modulated control scheme. So, the on-time of the switches varies depending on input-to-output voltage ratio and the load. During this on-time, the inductor connected to the converter is charged with current. In the remaining time, the time per ...
... The converter operates in a fixed-frequency, pulse-width-modulated control scheme. So, the on-time of the switches varies depending on input-to-output voltage ratio and the load. During this on-time, the inductor connected to the converter is charged with current. In the remaining time, the time per ...
MAX11205 16-Bit, Single-Channel, Ultra-Low Power, Delta-Sigma ADC with 2-Wire Serial Interface General Description
... The MAX11205 is an ultra-low-power (< 300FA max active current), high-resolution, serial-output ADC. This device provides the highest resolution per unit power in the industry, and is optimized for applications that require very high dynamic range with low power such as sensors on a 4mA to 20mA indu ...
... The MAX11205 is an ultra-low-power (< 300FA max active current), high-resolution, serial-output ADC. This device provides the highest resolution per unit power in the industry, and is optimized for applications that require very high dynamic range with low power such as sensors on a 4mA to 20mA indu ...
r630 automatic voltage regulator
... AVRs in the R600 series are designed for use on brushless self-excited generators, without slip-rings, with "SHUNT", "SHUNT with BOOSTER" or "PMG" or "AREP" excitation. In the case of "SHUNT with BOOSTER", the booster current is monitored by the AVR. ...
... AVRs in the R600 series are designed for use on brushless self-excited generators, without slip-rings, with "SHUNT", "SHUNT with BOOSTER" or "PMG" or "AREP" excitation. In the case of "SHUNT with BOOSTER", the booster current is monitored by the AVR. ...
SPZB260C-PRO
... This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate ...
... This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate ...
DESIGN AND IMPLEMENTATION OF PROGRAMMABLE
... occurred the relay will trip the total circuit. And it will be monitored on the LCD. LCD displays are used to display the status of circuit breaker. For protection from over current condition first we have to measure the total load current. Here we are using CT for measuring the load current and the ...
... occurred the relay will trip the total circuit. And it will be monitored on the LCD. LCD displays are used to display the status of circuit breaker. For protection from over current condition first we have to measure the total load current. Here we are using CT for measuring the load current and the ...
16264-Static uninterruptible power supply
... 2 sets of batteries operating in parallel]. UPS is to be maintained (continuously supplying load through the inverter), with automatic no-break transfer to or retransfer from alternate source (bypass) in case of failure or overload on rectifier- battery-inverter system. ...
... 2 sets of batteries operating in parallel]. UPS is to be maintained (continuously supplying load through the inverter), with automatic no-break transfer to or retransfer from alternate source (bypass) in case of failure or overload on rectifier- battery-inverter system. ...
TMP708 - Texas Instruments
... TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous mater ...
... TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous mater ...
Boomstar Modular User Manual.pages
... This Limited Warranty applies only to ANALOGIA INC./STUDIO ELECTRONICS purchased in the United States of America. Outside the USA, warranty policy and service is determined by the laws of the country of purchase and followed by our local authorized distributor. A listing of our authorized distributo ...
... This Limited Warranty applies only to ANALOGIA INC./STUDIO ELECTRONICS purchased in the United States of America. Outside the USA, warranty policy and service is determined by the laws of the country of purchase and followed by our local authorized distributor. A listing of our authorized distributo ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.