• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Implementing peak current mode control of a
Implementing peak current mode control of a

... Without slope compensation, these oscillations will cause the output to become unstable, with large deviations from the normal operating parameters. In the PCMC system, measuring the inductor current, “leading edge blanking” should also be added to our comparator input. This is due to the current ...
P83966
P83966

... The series STH-MSR Cluster Speaker Assembly is designed for ceiling or wall mounting in high ambient noise level environments. The Series STH-MSR Cluster Speakers are a speaker/visual alerting system, equipped with UL Listed STH-15SR supervised horn loudspeakers, and a UL Listed DC-MAX-C Strobe, mou ...
LM26003/LM26003Q 3A Switching Regulator with High Efficiency
LM26003/LM26003Q 3A Switching Regulator with High Efficiency

BQ24010 数据资料 dataSheet 下载
BQ24010 数据资料 dataSheet 下载

... Voltage on ISET pin, VCC ≥ 4.5 V, VIN ≥ 4.5 V, VI(BAT) > V(LOWV), VIN – VI(BAT) > V(DO–MAX), VO(REG) = 4.2 V ...
Characterization of CMOS Fully Differential Amplifiers for
Characterization of CMOS Fully Differential Amplifiers for

Power Supply Unit: Transformer Skill: Diagnosing a transformer that
Power Supply Unit: Transformer Skill: Diagnosing a transformer that

... A transformer is used in many electronic instruments. Sometimes, equipment is used in a different country than it was manufactured for. External transformers are used to adapt the equipment to the mains voltage difference. External transformers are also called wall transformers. The secondary voltag ...
TPS62065x 3-MHz 2A step down converter in a 2x2 SON package
TPS62065x 3-MHz 2A step down converter in a 2x2 SON package

... save mode and operates then in pulse frequency modulation (PFM) mode. During PWM operation the converter use a unique fast response voltage mode controller scheme with input voltage feed-forward to achieve good line and load regulation allowing the use of small ceramic input and output capacitors. A ...
Patch-clamp amplifiers on a chip - e-Lab
Patch-clamp amplifiers on a chip - e-Lab

... the charging of the membrane capacitance Cm , which is typically in the range of 20–40 pF. These circuits have been implemented as a first-order state-variable filter (Sigworth, 1995a,b) in which the time constant is roughly 100 !s to 1 ms. Due to the limited capacitor sizes, and therefore short tim ...
ROMANSO ELECTRONICS CO., LTD NAME: DMX Controller
ROMANSO ELECTRONICS CO., LTD NAME: DMX Controller

... DMX controller adopts the advanced micro-control unit,it is used for controlling a variety of lamp whose source of light is LED. For instance, point source of light,flexible light strip, wall washer lamp, glass curtain wall light and so on; It has many advantages such as easy connection and simplici ...
An Improved VFO Driver Amp for Tube Rigs
An Improved VFO Driver Amp for Tube Rigs

... This article, which was published nearly 20 years ago, is one of the few treatments of a subject which has been the focus of discussion for many vintageequipment users’ groups. I eventually built the DeMaw circuit (see fig. 1; this was called figure 2 in the original article), which consisted of a 1 ...
Common AC Power Distribution Configurations
Common AC Power Distribution Configurations

... Single Phase 120 often called house current is the AC power used in commercial buildings and houses to power lights and small appliances. The output voltage is 120Vac line to neutral (L-N). Line to neutral may also be called phase to neutral. There is both a 2 wire and a 3 wire configuration. The 2 ...
Design and Implement Harmonics Injection Source for Voltage
Design and Implement Harmonics Injection Source for Voltage

... nonlinear in the system. In addition, the simulation model of step-up transformer and the WVT are not enough accurate while the computational complexity is difficult. Therefore, the simulation is roughly tuning the value of the filter. The tuning aiming performance is listed as follow Step.1.Accordi ...
Technical information VDE 0530
Technical information VDE 0530

... An exact definition of the types of operation is necessary in order to ensure that limit temperatures listed in 1 are not exceeded. For this the steady-state temperature and the final state temperature is defined in such a way that the excess temperature ∆ϑ during one hour of operation may change by ...
SKE-300 Series Pre-Engineered Voice Evacuation Systems - AV-iQ
SKE-300 Series Pre-Engineered Voice Evacuation Systems - AV-iQ

instructions to tenderers
instructions to tenderers

... Dc/ac voltage changer Variable voltage output magnetothermic protection On the back panel the following elements will be included: Maximum speed protection connector General differential magnetothermic switch Fixed voltage output magnetothermic switch Single phase socket Supply cord, 3 m long Three- ...
ac current
ac current

... a zero reading. *Choose the proper range and function for the measurement . do not try voltage or current measurements that may exceed the ratings marked on the function/range switch or terminal. *When measuring current. Connect the meter in series with the load. *Never connect more than one set of ...
LT1175 - 500mA Negative Low Dropout
LT1175 - 500mA Negative Low Dropout

TLC254, TLC254A, TLC254B, TLC254Y, TLC25L4, TLC25L4A, TLC25L4B
TLC254, TLC254A, TLC254B, TLC254Y, TLC25L4, TLC25L4A, TLC25L4B

... ideally suited for battery-powered or energy-conserving applications. The series offers operation down to a 1.4-V supply, is stable at unity gain, and has excellent noise characteristics. These devices have internal electrostatic-discharge (ESD) protection circuits that prevent catastrophic failures ...
Lecture 10 - UniMAP Portal
Lecture 10 - UniMAP Portal

... increased interest from various districts of the world. The turning propellers of the wind-power station are connected directly to the shaft of an ac generator. ...
FJAFS1720 ESBC Rated NPN Power Transistor ™
FJAFS1720 ESBC Rated NPN Power Transistor ™

Evaluates:  MAX1562/MAX1562H/MAX1563 MAX1563 Evaluation Kit General Description Features
Evaluates: MAX1562/MAX1562H/MAX1563 MAX1563 Evaluation Kit General Description Features

... on that output is continuously above 0.5V (typ) for 20ms (typ), then the fault is reset and the output is turned back on. The voltage on the output is monitored so that a short-circuit condition can be detected. Active loads are not expected to have measurable currents when the supply is below 0.5V. ...
Agtron ST Seed Sensor Datasheet Rev 04
Agtron ST Seed Sensor Datasheet Rev 04

... Optical Detection Elements…..………………………………………..4 Optical Sampling Frequency (1) ..……………………………………. 15 kHz Optical Detection Zone………………………………………………… 2mm Minimum Particle Detection Size .……………………………………. 1.5mm Minimum Optical Cross Section Coverage .………………………….40% Optical Calibration Steps (2).………………………… ...
Universal LightProbe™ Penta High Sensitivity Sensors
Universal LightProbe™ Penta High Sensitivity Sensors

... Universal LightProbe Sensors offer reliability and versatility, operating at any voltage from +5 volts to +40 volts and withstanding reverse polarity up to -18 volts without permanent damage. This provides immunity from accidental power supply wiring mistakes and from reverse polarity up to -18 volt ...
MAX1807/MAX1808 Micropower Adjustable Overvoltage Protection Controllers General Description
MAX1807/MAX1808 Micropower Adjustable Overvoltage Protection Controllers General Description

... The MAX1807/MAX1808 provide overvoltage protection for systems with multiple supply rails. Very low output voltage supplies can have an overvoltage before the power-supply controller has sufficient supply voltage to activate protection circuitry. The MAX1807/MAX1808 offer a system-wide approach to e ...
PDF
PDF

... higher magnitude of fundamental output voltage www.ijera.com ...
< 1 ... 848 849 850 851 852 853 854 855 856 ... 1974 >

Mains electricity



Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report