interleaved boost converter
... considered. The effect of power loss has been assessed on the temperature, which is a stress factor in the reliability analysis. Then, the failure rate of converter components has been calculated based on their power loss in different scenarios. The results show that with an increase in power, the r ...
... considered. The effect of power loss has been assessed on the temperature, which is a stress factor in the reliability analysis. Then, the failure rate of converter components has been calculated based on their power loss in different scenarios. The results show that with an increase in power, the r ...
Dated: 12/2015 - University of Kentucky
... Secondary voltage - 120/208 Y volts or 277/480 Y volts, 30 kV BIL. The low voltage neutral shall be brought out through a fully insulated bushing in the secondary compartment and grounded externally. ...
... Secondary voltage - 120/208 Y volts or 277/480 Y volts, 30 kV BIL. The low voltage neutral shall be brought out through a fully insulated bushing in the secondary compartment and grounded externally. ...
Sinusoidal current injection based on a line
... is already modulated to track a rectified sinusoidal waveform and the function of the circuit is to re-create the sinusoidal waveform and inject it into the grid [4]. The CSI generates an ac output current waveform composed of discrete values; therefore, a capacitor filter should be used between the ...
... is already modulated to track a rectified sinusoidal waveform and the function of the circuit is to re-create the sinusoidal waveform and inject it into the grid [4]. The CSI generates an ac output current waveform composed of discrete values; therefore, a capacitor filter should be used between the ...
MMBT3906FA Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
Charge Controllers
... voltage drops. Voltage drops affect the voltage measured by the charge controller. ...
... voltage drops. Voltage drops affect the voltage measured by the charge controller. ...
SR100B_E - Innovative Energies
... Components within the power supply responsible for providing the safety barrier between input and output are constructed to provide electrical isolation as required by the relevant standard. However EMI filtering components could be damaged as result of excessively long high voltage tests between in ...
... Components within the power supply responsible for providing the safety barrier between input and output are constructed to provide electrical isolation as required by the relevant standard. However EMI filtering components could be damaged as result of excessively long high voltage tests between in ...
Auto-Zero Amplifiers
... A wide variety of electronic applications, especially those involving very small input signals, require signal paths with very low offset voltage and offset voltage drift over time and temperature. When standard linear components are used, the only way to achieve this low offset and drift is to use ...
... A wide variety of electronic applications, especially those involving very small input signals, require signal paths with very low offset voltage and offset voltage drift over time and temperature. When standard linear components are used, the only way to achieve this low offset and drift is to use ...
AAT4687-1 数据资料DataSheet下载
... internally, the device immediately turns off the internal P-channel FET, disconnecting the load from the input and preventing damage to downstream components. Simultaneously, the fault flag is raised, alerting the system to a problem. If an over-voltage condition is applied at the time of the device ...
... internally, the device immediately turns off the internal P-channel FET, disconnecting the load from the input and preventing damage to downstream components. Simultaneously, the fault flag is raised, alerting the system to a problem. If an over-voltage condition is applied at the time of the device ...
EXPERIMENT NO 4
... (iii) Use X-Y mode and obtain the Vo vs Vi transfer characteristics. Sketch the characteristics and note down all the salient points. Indicate the modes of operation of the BJT in the different regions of the characteristics. (iv) Now use RC= 15K and repeat steps (ii) and (iii) above. (v) Using the ...
... (iii) Use X-Y mode and obtain the Vo vs Vi transfer characteristics. Sketch the characteristics and note down all the salient points. Indicate the modes of operation of the BJT in the different regions of the characteristics. (iv) Now use RC= 15K and repeat steps (ii) and (iii) above. (v) Using the ...
RF2514 VHF/UHF TRANSMITTER Features
... The transmit amplifier is a two-stage amplifier consisting of a driver and an open collector final stage. It is capable of providing 5dBm of output power into a 50Ω load while operating from a 3.6V power supply. The lock-detect circuitry connects to the output of the phase detector circuitry and is ...
... The transmit amplifier is a two-stage amplifier consisting of a driver and an open collector final stage. It is capable of providing 5dBm of output power into a 50Ω load while operating from a 3.6V power supply. The lock-detect circuitry connects to the output of the phase detector circuitry and is ...
A 20 Gb/s 0.3 pJ/b Single-Ended Die-to-Die
... impedance – decreases the amount of low frequency current being drawn from the transmitter power supply resulting in significant power savings. For example, adding a 100-Ohm DC resistance to the transmitter of a doubly-terminated 50Ohm per side link with a 1-V supply voltage, reduces the average DC ...
... impedance – decreases the amount of low frequency current being drawn from the transmitter power supply resulting in significant power savings. For example, adding a 100-Ohm DC resistance to the transmitter of a doubly-terminated 50Ohm per side link with a 1-V supply voltage, reduces the average DC ...
analysis of load test, transformation, turns ratio, efficiency and
... Transformer is a static device which transfers electrical energy from one circuit to another without change in frequency [3]. Most of the cases we see that the inputs given are sinusoidal wave only. In modern electrical distribution system, there has been a sudden increase of nonlinear loads, such a ...
... Transformer is a static device which transfers electrical energy from one circuit to another without change in frequency [3]. Most of the cases we see that the inputs given are sinusoidal wave only. In modern electrical distribution system, there has been a sudden increase of nonlinear loads, such a ...
Slide - Indico
... Active leakage current detection level is 5 times higher that the maximum leakage accepted in the specification The leakage may change depending on the machine/circuit conditions. It is essential to store all the measurements during the time to allow analysis and understanding of the variation ...
... Active leakage current detection level is 5 times higher that the maximum leakage accepted in the specification The leakage may change depending on the machine/circuit conditions. It is essential to store all the measurements during the time to allow analysis and understanding of the variation ...
Advantage 212 — Variable Speed AC drives
... Selectable from 6 to 16 kHz, 12 kHz nominal rating for 1 HP to 20 HP @ 200/240 V, 380/480 V Selectable: 6 to 16 kHz, 8kHz nominal rating for 30 HP to 40 HP @ 200/240 V, 30 HP to 100 HP @ 380/480 V ...
... Selectable from 6 to 16 kHz, 12 kHz nominal rating for 1 HP to 20 HP @ 200/240 V, 380/480 V Selectable: 6 to 16 kHz, 8kHz nominal rating for 30 HP to 40 HP @ 200/240 V, 30 HP to 100 HP @ 380/480 V ...
Si2318DS
... typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in ...
... typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in ...
Selection Guide
... PTCs operate as a positive temperature coefficient device. High temperatures and excessive current will cause the device resistance to increase until it limits the unsafe current level. Upon reaching the design temperature/current limit, the PTC will effectively “open” the circuit to provide protect ...
... PTCs operate as a positive temperature coefficient device. High temperatures and excessive current will cause the device resistance to increase until it limits the unsafe current level. Upon reaching the design temperature/current limit, the PTC will effectively “open” the circuit to provide protect ...
Distribution transformers
... at rated withstand voltage and nominal frequency). This test is also known as the “applied overvoltage test” and is intended to check the insulation of one winding from all other transformer components. >> Double voltage test (1 minute at double voltage and double frequency) induced via the low volt ...
... at rated withstand voltage and nominal frequency). This test is also known as the “applied overvoltage test” and is intended to check the insulation of one winding from all other transformer components. >> Double voltage test (1 minute at double voltage and double frequency) induced via the low volt ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.