OICA Draft Proposal for the ELSA
... However, this provision does not apply under conditions where an internal combustion engine provides directly or indirectly the vehicle´s propulsion power. When leaving the vehicle, the driver shall be informed by a signal (e.g. optical or audible signal) if the vehicle is still in the active drivin ...
... However, this provision does not apply under conditions where an internal combustion engine provides directly or indirectly the vehicle´s propulsion power. When leaving the vehicle, the driver shall be informed by a signal (e.g. optical or audible signal) if the vehicle is still in the active drivin ...
FTB 317 Manual Rev 1
... every practical safety precaution, exercise extreme caution at all times when you expose circuits and components, and when you operate, maintain, or service this equipment. ...
... every practical safety precaution, exercise extreme caution at all times when you expose circuits and components, and when you operate, maintain, or service this equipment. ...
University Improves Sustainability of HVAC Motors in
... A new preventive maintenance program at a leading New England Ivy League university demonstrates how the push for more sustainable “green” building management has led to a growing awareness of a chronic, widespread problem with HVAC motors — electrical bearing damage and failure. VFDs, also known as ...
... A new preventive maintenance program at a leading New England Ivy League university demonstrates how the push for more sustainable “green” building management has led to a growing awareness of a chronic, widespread problem with HVAC motors — electrical bearing damage and failure. VFDs, also known as ...
Muon Pretrigger Electronics - Institut für Experimentalphysik
... alarm immediately switches off the power supply of the corresponding Pot. In case of no alarm the power supply of a certain Pot can be switched by the Switch Module, which is located in the Control Room 101. The switch command passes the Sensor Module and is sent to the Relay Box, where a relay conn ...
... alarm immediately switches off the power supply of the corresponding Pot. In case of no alarm the power supply of a certain Pot can be switched by the Switch Module, which is located in the Control Room 101. The switch command passes the Sensor Module and is sent to the Relay Box, where a relay conn ...
ARCMASTER® 185 AC/DC 200 AC/DC Service Manual
... strictly observe all safety rules and take precautionary actions. Safe practices have developed from past experience in the use of welding and cutting. These practices must be learned through study and training before using this equipment. Some of these practices apply to equipment connected to powe ...
... strictly observe all safety rules and take precautionary actions. Safe practices have developed from past experience in the use of welding and cutting. These practices must be learned through study and training before using this equipment. Some of these practices apply to equipment connected to powe ...
S47-0079 - Exide Technologies
... For the best operating conditions and longest life, take care in selecting an installation site. Avoid locations exposed to high humidity, temperature extremes or dust. Moisture condensing on machine parts and electrical components can cause corrosion, which seriously affects operation, efficiency a ...
... For the best operating conditions and longest life, take care in selecting an installation site. Avoid locations exposed to high humidity, temperature extremes or dust. Moisture condensing on machine parts and electrical components can cause corrosion, which seriously affects operation, efficiency a ...
165-260
... recognize the unique waveform characteristics of these selfclearing faults. See Figure 3. By counting how often these events occur over a moving time window, the iTAP-260 is able to give advance notice of pending cable splice failures. This permits cable maintenance to be scheduled rather than addre ...
... recognize the unique waveform characteristics of these selfclearing faults. See Figure 3. By counting how often these events occur over a moving time window, the iTAP-260 is able to give advance notice of pending cable splice failures. This permits cable maintenance to be scheduled rather than addre ...
Operations Manual
... hard you try. It's like enjoying fresh food or food that's been frozen. Something gets lost in the translation. We feel our designs go a few steps beyond those of other manufacturers! In addition to refining our circuit designs and operating points with computer "Spice" modeling, we also spend count ...
... hard you try. It's like enjoying fresh food or food that's been frozen. Something gets lost in the translation. We feel our designs go a few steps beyond those of other manufacturers! In addition to refining our circuit designs and operating points with computer "Spice" modeling, we also spend count ...
Full-Text PDF
... renewable sources will be low and must be stepped up by using a DC-DC converter for photovoltaic applications. 2 K diodes and 2 K capacitors along with two semiconductor control switch are used in the K-stage proposed converter to obtain an output voltage which is (K + 1) times the input voltage. Th ...
... renewable sources will be low and must be stepped up by using a DC-DC converter for photovoltaic applications. 2 K diodes and 2 K capacitors along with two semiconductor control switch are used in the K-stage proposed converter to obtain an output voltage which is (K + 1) times the input voltage. Th ...
Manual Usuario Bateria de Litio-Ion de 24V 180Ah y derivador Lynx
... Make sure that all energy consumers are switched off before starting up the system. The Lynx Ion + Shunt will pre-charge the system before closing the safety contactor. The Lynx Ion + Shunt will not start if there is more than 10A drawn by the system during pre-charging. Press the START-button on th ...
... Make sure that all energy consumers are switched off before starting up the system. The Lynx Ion + Shunt will pre-charge the system before closing the safety contactor. The Lynx Ion + Shunt will not start if there is more than 10A drawn by the system during pre-charging. Press the START-button on th ...
SN65LVCP202 数据资料 dataSheet 下载
... The SN65LVCP202 built-in passive input equalizer compensates for ISI. For a 20-inch (50,8-cm) FR4 transmission line with 8-mil (0,2-mm) trace width, the SN65LVCP202 typically reduces jitter by 60 ps from the device input to the device output. Absolute deterministic output jitter reflects the determi ...
... The SN65LVCP202 built-in passive input equalizer compensates for ISI. For a 20-inch (50,8-cm) FR4 transmission line with 8-mil (0,2-mm) trace width, the SN65LVCP202 typically reduces jitter by 60 ps from the device input to the device output. Absolute deterministic output jitter reflects the determi ...
UM6K33N
... "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. ...
... "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. ...
LTC4150 - Coulomb Counter/Battery Gas Gauge
... presence of noise, spikes and ripple. 4.7μF is recommended for general applications but can be extended to higher values as long as the capacitor’s leakage is low. A 10nA leakage is roughly equivalent to the input offset error of the integrator. Ceramic capacitors are suitable for this use. Switchin ...
... presence of noise, spikes and ripple. 4.7μF is recommended for general applications but can be extended to higher values as long as the capacitor’s leakage is low. A 10nA leakage is roughly equivalent to the input offset error of the integrator. Ceramic capacitors are suitable for this use. Switchin ...
Analysis of an array of piezoelectric energy harvesters connected in
... array structure attached to various energy harvesting circuits, including standard and parallel-/series-SSHI (synchronized switch harvesting on inductor) interfaces. They have shown that the electrical response of a PEH array can be changed from the power-boosting mode to the wideband mode by adjust ...
... array structure attached to various energy harvesting circuits, including standard and parallel-/series-SSHI (synchronized switch harvesting on inductor) interfaces. They have shown that the electrical response of a PEH array can be changed from the power-boosting mode to the wideband mode by adjust ...
BDTIC www.BDTIC.com/infineon AN2012-08 Evaluation Adapter Board for 62mm Half Bridge IGBT Modules
... Active clamping is a technique which keeps transient overvoltages below the critical limits when the IGBT turns off. The standard approach for active clamping is to use a chain of avalanche diodes connected between the auxiliary collector and the gate of an IGBT module. When the collector-emitter vo ...
... Active clamping is a technique which keeps transient overvoltages below the critical limits when the IGBT turns off. The standard approach for active clamping is to use a chain of avalanche diodes connected between the auxiliary collector and the gate of an IGBT module. When the collector-emitter vo ...
sadler_appnote
... UPS systems can be categorized as either on-line or off-line (standby). An on-line UPS is constantly engaged, converting all incoming power to DC current that passes though the battery circuit and is then converted back to AC again. Equipment connected to the on-line UPS is electrically isolated fro ...
... UPS systems can be categorized as either on-line or off-line (standby). An on-line UPS is constantly engaged, converting all incoming power to DC current that passes though the battery circuit and is then converted back to AC again. Equipment connected to the on-line UPS is electrically isolated fro ...
DATA SHEET BUJ105AB Silicon Diffused Power Transistor
... party customer(s). Customer is responsible for doing all necessary testing for the customer’s applications and products using NXP Semiconductors products in order to avoid a default of the applications and the products or of the application or use by customer’s third party customer(s). NXP does not ...
... party customer(s). Customer is responsible for doing all necessary testing for the customer’s applications and products using NXP Semiconductors products in order to avoid a default of the applications and the products or of the application or use by customer’s third party customer(s). NXP does not ...
Neutral Point Clamped and Cascaded H
... Objectives: This work emphasizes on the analysis of two five levels inverter topologies - neutral point clamped topology and Cascaded H-Bridge inverter topology. Methods/Analysis: The neutral point clamped topology requires only one DC source, eight switches and four clamping diodes with two voltage ...
... Objectives: This work emphasizes on the analysis of two five levels inverter topologies - neutral point clamped topology and Cascaded H-Bridge inverter topology. Methods/Analysis: The neutral point clamped topology requires only one DC source, eight switches and four clamping diodes with two voltage ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.