• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Alpha AR User Guide
Alpha AR User Guide

... Remove the operate circuit test supply On latching relays perform a manual contact reset and confirm the contact state change with a suitable continuity tester On relays fitted with a mechanical flag reset the flag On relays fitted with an electrical reset circuit, repeat step 5 through to 7 Ensure ...
MX Series AC and DC Power Source User Manual
MX Series AC and DC Power Source User Manual

... Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel and equipment safety. Always ensure that facility AC input power is de-energized prior to connecting or disconnecting any cable. In normal operation, the operator ...
Transient Peak Currents in Permanent Magnet Synchronous Motors
Transient Peak Currents in Permanent Magnet Synchronous Motors

... case of an inverter protection shut down during the flux weakening operation the induced open-circuit terminal voltage may exceed the allowed inverter limit [4]. That is why a symmetrical short circuit (SSC) is to be discussed as alternative protection measure. To do so, an accurate knowledge of the ...
MAX14811 Dual, Unipolar/Bipolar, High
MAX14811 Dual, Unipolar/Bipolar, High

... Note 2: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a fourlayer board. For detailed information on package thermal considerations, refer to www.maxim-ic.com/thermal-tutorial. Stresses beyond those listed under “Absolute Maximum Ratings ...
Earth fault current distribution on transmission networks
Earth fault current distribution on transmission networks

... m or more. The length of cables used at the highest transmission voltages is limited due to the substantial costs involved, however as cable voltages reduce, the cost premium compared to an equivalent overhead line falls. • Substations A transmission substation connects two or more transmission line ...
MAX1191 Ultra-Low-Power, 7.5Msps, Dual 8-Bit ADC General Description Features
MAX1191 Ultra-Low-Power, 7.5Msps, Dual 8-Bit ADC General Description Features

... ultra-low operating power, the MAX1191 features three power-down modes to conserve power during idle periods. Excellent dynamic performance, ultra-low power, and small size make the MAX1191 ideal for applications in imaging, instrumentation, and digital communications. An internal 1.024V precision b ...
Choosing the Right Cable
Choosing the Right Cable

Product Guide, Generator protection REG650, IEC
Product Guide, Generator protection REG650, IEC

... thermal power plants. This enables adaptation to the protection requirements of most generating plants. Protection functions are available for detecting and clearing internal faults, such as generator stator short circuits and earth faults, generator rotor earth faults, unit transformer short circui ...
2. Bulk Electric System Facilities
2. Bulk Electric System Facilities

... NHT equipment is designed to operate within the ranges of voltage, frequency, fault current and transient conditions for which it is intended to function. This consideration of operating limitations is applicable to all equipment on the BES. For considerations unique to the specific equipment, refer ...
Rogowski Coil
Rogowski Coil

APT Generator Quick Connection Switchboard (FS Series)
APT Generator Quick Connection Switchboard (FS Series)

... Switchboard shall consist of the required number of vertical sections bolted together to form a rigid assembly. The sides and rear shall be covered with removable bolt-on covers. All edges of front covers or hinged front panels shall be formed. Adequate ventilation within the enclosure shall be prov ...
Low-Voltage 4-Bit 1-of-2 FET Multiplexer
Low-Voltage 4-Bit 1-of-2 FET Multiplexer

... The SN74CBTLV3257 is a 4-bit 1-of-2 high-speed FET multiplexer/demultiplexer. The low on-state resistance of the switch allows connections to be made with minimal propagation delay. The select (S) input controls the data flow. The FET multiplexers/demultiplexers are disabled when the output-enable ( ...
Conzerv EM6435 Energy Meter
Conzerv EM6435 Energy Meter

Model 9007
Model 9007

... a bare, green, or white wire in AC wiring circuits) using the insulated slip-on Alligator Clips. Then probe for voltages with the other test lead. This helps prevent you from accidentally touching a hot wire, since you need to concentrate on only one test lead. Failure to observe this precaution may ...
Photovoltaic Module PHONO SOLAR TECHNOLOGY CO., LTD. Phono Solar Technology Co., Ltd.
Photovoltaic Module PHONO SOLAR TECHNOLOGY CO., LTD. Phono Solar Technology Co., Ltd.

Zolt Laptop Charger Plus User Guide
Zolt Laptop Charger Plus User Guide

... 6. Do not cover the adapter with paper or other materials or place anything closely around it while in operation that may obstruct the adapters built-in cooling properties 7. It is normal for chargers (including Zolt) to become warm during use. This is expected and safe. As a precaution, Zolt has ...
A Constant ON-Time 3-Level Buck Converter for Low Power
A Constant ON-Time 3-Level Buck Converter for Low Power

... Dr. Dong S. Ha, who has guided me throughout my graduate study at Virginia Tech. I would like thank Dr. Qiang Li for his help, guidance, and expert knowledge in power electronics that help me enormously with my thesis research. I would also like to thank Dr. Kwang-Jin Koh for being part of my adviso ...
ge energy - GE Industrial Solutions
ge energy - GE Industrial Solutions

... Plug-in Boxes 32A, 63A & 100A These are compact sheet-steel boxes with hinged-doors housing the fuse-holders, which are solidly connected to high conductivity copper clip-on contacts reinforced by spring steel strips. These clipon contacts plug directly on to the busbars at the plug-in points. For a ...
OMS JDM - One Byte CPU
OMS JDM - One Byte CPU

... designed for programming or development with PIC chips. In such cases, make sure the power, if any, is disconnected and that the board is not connected to anything except the JDM programmer, as shown to the right. Having said that, it may still work well in a standard ICSP role, as long as the PIC’s ...
Electrical Hazards
Electrical Hazards

... Illumination (Over 600 Volts) • Adequate illumination must be provided for all working spaces around electrical equipment. • The lights and switches must be arranged so that persons making repairs or turning on lights wont contact live ports. ...
Presentation
Presentation

... K.104: Method for identifying the transfer potential of the earth potential rise from high or medium voltage networks to the earthing system or neutral of low voltage networks K.107: Method for determining the impedance to earth of earthing systems. K.108: Joint-use of poles by telecommunication and ...
2016 SMS Under Counter Refrigeration Catalog
2016 SMS Under Counter Refrigeration Catalog

... Superior Reliability: Danfoss / Secop compressors backed by Isotherm’s 5-year limited warranty Extra-thick insulation for low power consumption  New freezer design reduces frosting issues and has magnetic door holder for easy access  Blue LED internal lighting  Innovative vent-lock system ...
DAC8580 数据资料 dataSheet 下载
DAC8580 数据资料 dataSheet 下载

... This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete devi ...
MOV Protection of Series Capacitor Banks
MOV Protection of Series Capacitor Banks

INSTRUCTION MANUAL Sunshine Duration Meter MS-093
INSTRUCTION MANUAL Sunshine Duration Meter MS-093

< 1 ... 144 145 146 147 148 149 150 151 152 ... 1974 >

Mains electricity



Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report