MAX5486 Stereo Volume Control with Pushbutton Interface General Description
... Average Current into H_, L_, and W_ .................................±1mA Maximum Continuous Current into H_, L_ ..........................±4mA Input and Output Latchup Immunity...............................±200mA Continuous Power Dissipation (TA = +70°C) 24-Pin TSSOP (derate 8.3mW/°C above +70°C) ...
... Average Current into H_, L_, and W_ .................................±1mA Maximum Continuous Current into H_, L_ ..........................±4mA Input and Output Latchup Immunity...............................±200mA Continuous Power Dissipation (TA = +70°C) 24-Pin TSSOP (derate 8.3mW/°C above +70°C) ...
The thyristor switched and conventionally switched harmonic filter
... conventionally switched harmonic filter bank. This equipment is designed to provide “fast” vars, using thyristor valves to mitigate voltage flicker and voltage sags, and “slow” vars using conventional capacitor switches to economically correct power factor and attenuate harmonic distortion attenuati ...
... conventionally switched harmonic filter bank. This equipment is designed to provide “fast” vars, using thyristor valves to mitigate voltage flicker and voltage sags, and “slow” vars using conventional capacitor switches to economically correct power factor and attenuate harmonic distortion attenuati ...
MAX3353E USB On-the-Go Charge Pump with Switchable Pullup/Pulldown Resistors General Description
... The MAX3353E level-detector comparators monitor important VBUS voltages needed to support SRP and HNP and provides an interrupt output signal for OTG events that require action. The VBUS power-control block performs the various switching functions required by an OTG dual-role device and is programma ...
... The MAX3353E level-detector comparators monitor important VBUS voltages needed to support SRP and HNP and provides an interrupt output signal for OTG events that require action. The VBUS power-control block performs the various switching functions required by an OTG dual-role device and is programma ...
How to build the Seth PP2A3
... be higher. Due to the large number of pictures, having high resolution pictures would have made for a pretty large file. A CD containing all the pictures contained here but in a higher resolution will be given for free to all those who will have bought the Seth iron package from Pantheon Audio. Bori ...
... be higher. Due to the large number of pictures, having high resolution pictures would have made for a pretty large file. A CD containing all the pictures contained here but in a higher resolution will be given for free to all those who will have bought the Seth iron package from Pantheon Audio. Bori ...
MAX11164 16-Bit, 500ksps, 0 to 5V SAR ADC with General Description
... OVDD to GND........ -0.3V to the lower of (VDD + 0.3V) and +6V AIN+ to GND............................................................-0.3V to +6V ...
... OVDD to GND........ -0.3V to the lower of (VDD + 0.3V) and +6V AIN+ to GND............................................................-0.3V to +6V ...
chapter 2 examples and tables
... A common grounding electrode conductor serving several separately derived systems is an alternative to installing individual grounding electrode conductors from each separately derived system to the grounding electrode system. In such an arrangement, a tapped grounding electrode conductor is install ...
... A common grounding electrode conductor serving several separately derived systems is an alternative to installing individual grounding electrode conductors from each separately derived system to the grounding electrode system. In such an arrangement, a tapped grounding electrode conductor is install ...
AN2446
... Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notic ...
... Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notic ...
Can you dim 100x 5W LED`s with a 500W dimmer?
... Can you dim 100x 5W LED's with a 500W dimmer? LED lighting technology provides numerous advantages for the end user compared to the older incandescent and halogen technologies. But to the installer or specifier, this new technology often creates headaches when it comes to the practical implementatio ...
... Can you dim 100x 5W LED's with a 500W dimmer? LED lighting technology provides numerous advantages for the end user compared to the older incandescent and halogen technologies. But to the installer or specifier, this new technology often creates headaches when it comes to the practical implementatio ...
INSTRUCTION MANUAL Varec Model 6850 Field Interface Converter
... applications. For instance, it can be used with a modem to provide communications over long distances. It can also be used as an EIA-485 repeater to extend the distance of EIA-485 communications. The Model 6850 is an industrial unit designed for operation in hostile environments. Components selected ...
... applications. For instance, it can be used with a modem to provide communications over long distances. It can also be used as an EIA-485 repeater to extend the distance of EIA-485 communications. The Model 6850 is an industrial unit designed for operation in hostile environments. Components selected ...
TPS23750 Flyback-Converter Evaluation Board
... PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. Persons handling the product(s) must have electronics training and observe good engineering practice standards. As such, the goods being provided are not intended to be complete in terms of required ...
... PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. Persons handling the product(s) must have electronics training and observe good engineering practice standards. As such, the goods being provided are not intended to be complete in terms of required ...
Liebert Series 610 UPS DISCONTINUED PRODUCT
... cabinet. Test lift and balance the cabinets before transporting. Maintain minimum tilt from vertical at all times. Slots at the base of the modules and battery cabinets are intended for forklift use. Base slots will support the unit only if the forks are completely beneath the unit. Follow all batte ...
... cabinet. Test lift and balance the cabinets before transporting. Maintain minimum tilt from vertical at all times. Slots at the base of the modules and battery cabinets are intended for forklift use. Base slots will support the unit only if the forks are completely beneath the unit. Follow all batte ...
Slide 1 - University of California, Berkeley
... M1 and M2 have the same VGS If we neglect CLM (λ=0), then the drain currents are equal Since λ is small, the currents will nearly mirror one another even if Vout is not equal to VGS1 We say that the current IREF is mirrored into iOUT Notice that the mirror works for small and large signals! Universi ...
... M1 and M2 have the same VGS If we neglect CLM (λ=0), then the drain currents are equal Since λ is small, the currents will nearly mirror one another even if Vout is not equal to VGS1 We say that the current IREF is mirrored into iOUT Notice that the mirror works for small and large signals! Universi ...
User’s Manual Model PR300 Power and Energy Meter
... To avoid electric shock, be sure to provide protective grounding before turning on the Meter. ● Need for protective grounding Do not cut the internal or external protective grounding conductor of the Meter or disconnect the conductor from the protective grounding terminal. In either case, the protec ...
... To avoid electric shock, be sure to provide protective grounding before turning on the Meter. ● Need for protective grounding Do not cut the internal or external protective grounding conductor of the Meter or disconnect the conductor from the protective grounding terminal. In either case, the protec ...
Modular Smart Grid Power Systems Simulators (Utilities) AEL-MPSS Technical Teaching Equipment
... to be able to work either independently or combining with several options and applications in order to configure systems simulators (generation + trasmission/ distribution + loads). Due to the flexibility of our modular applications, it is possible to begin with easy applications for students with b ...
... to be able to work either independently or combining with several options and applications in order to configure systems simulators (generation + trasmission/ distribution + loads). Due to the flexibility of our modular applications, it is possible to begin with easy applications for students with b ...
# Investi ations Into the Use of Temperature Detectors as
... used on larger machines, the leads are sometimes contained within a grounded metal shield to reduce electrical interference, and hence the risk of poor ternpcrature readings. The lead lengths from the sensors to the terminal panel can vary significantly From RTD to RTD, even in the samc stator. In m ...
... used on larger machines, the leads are sometimes contained within a grounded metal shield to reduce electrical interference, and hence the risk of poor ternpcrature readings. The lead lengths from the sensors to the terminal panel can vary significantly From RTD to RTD, even in the samc stator. In m ...
building energy management system controllers
... BACnet over IP as standard. Trend communications over a current loop LAN is available as an option. A local PC or display (e.g. IQ®View4) can be connected to the RS232 port. A Wallbus port is also provided for use with room displays. ...
... BACnet over IP as standard. Trend communications over a current loop LAN is available as an option. A local PC or display (e.g. IQ®View4) can be connected to the RS232 port. A Wallbus port is also provided for use with room displays. ...
S9004
... Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. ...
... Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. ...
Quad IEEE 802.3at Power-Over-Ethernet Controller (Rev. B)
... current trip point can be set to all classification thresholds of IEEE Std 802.3-2005 (or 802.3af) and can be programmed up to more than 720 mA when used with a LLDP classification stack, complying with 802.3at. The TPS23851 supports AC and DC disconnection with a precision on-chip, 110-Hz oscillato ...
... current trip point can be set to all classification thresholds of IEEE Std 802.3-2005 (or 802.3af) and can be programmed up to more than 720 mA when used with a LLDP classification stack, complying with 802.3at. The TPS23851 supports AC and DC disconnection with a precision on-chip, 110-Hz oscillato ...
A New Algorithm for Digital Low-impedance Protection of Busbars
... computational power allowing for additional functions such as back-up OC protection or BF per circuit. • Centralized busbar protection requires wiring all the signals to a central location, where a single relay does all the processing. The wiring cannot be reduced and the calculations cannot be dist ...
... computational power allowing for additional functions such as back-up OC protection or BF per circuit. • Centralized busbar protection requires wiring all the signals to a central location, where a single relay does all the processing. The wiring cannot be reduced and the calculations cannot be dist ...
The Electrical Code Committee has been asked to convene for
... (3) The space afforded by fixed room dividers such as free standing bar-type counters or railings. Where room dividers consist of multiple moving panels only the first moving panel in each direction may be excluded as a wall space. JUSTIFICATION: Designs of homes in southern Nevada are often extreme ...
... (3) The space afforded by fixed room dividers such as free standing bar-type counters or railings. Where room dividers consist of multiple moving panels only the first moving panel in each direction may be excluded as a wall space. JUSTIFICATION: Designs of homes in southern Nevada are often extreme ...
10-1000 kW Operation
... working on the generator set or equipment connected to the set, disable the generator set as follows: (1) Press the generator set off/reset button to shut down the generator set. (2) Disconnect the power to the battery charger, if equipped. (3) Remove the battery cables, negative (--) lead first. Re ...
... working on the generator set or equipment connected to the set, disable the generator set as follows: (1) Press the generator set off/reset button to shut down the generator set. (2) Disconnect the power to the battery charger, if equipped. (3) Remove the battery cables, negative (--) lead first. Re ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.