Procedure for Koehler Digital Constant Temperature Viscosity Bath
... operating temperatures. If the bath temperature is unable to maintain the setpoint temperature and it begins to decline the OTP circuitry may have been activated. Procedure to rectify the situation: 1. Turn off the unit power switch and disconnect the line cord. 2. Locate the front tray where the t ...
... operating temperatures. If the bath temperature is unable to maintain the setpoint temperature and it begins to decline the OTP circuitry may have been activated. Procedure to rectify the situation: 1. Turn off the unit power switch and disconnect the line cord. 2. Locate the front tray where the t ...
Picture to parts, one thin metal layer at a time
... laser is used in the two laser-based processes to make parts from powders. In the powder bed fusion (PBF) process, shown schematically in Fig. 2(a), the bed is lowered by a small distance after each layer is deposited, a roller spreads a thin layer of powder over the part and its surrounding area be ...
... laser is used in the two laser-based processes to make parts from powders. In the powder bed fusion (PBF) process, shown schematically in Fig. 2(a), the bed is lowered by a small distance after each layer is deposited, a roller spreads a thin layer of powder over the part and its surrounding area be ...
Bipolar Junction Transistor - kmutt-inc
... the voltage rating applies, and the third letter is in reference to the third unmentioned terminal which is left open. The first voltage, VCBO indicates the maximum allowable collector-to-base voltage with the emitter open. The second voltage, VCEO is the maximum allowable collector-emitter voltage ...
... the voltage rating applies, and the third letter is in reference to the third unmentioned terminal which is left open. The first voltage, VCBO indicates the maximum allowable collector-to-base voltage with the emitter open. The second voltage, VCEO is the maximum allowable collector-emitter voltage ...
Thermoelectric effect
... a thermocouple, comprising a p-type and n-type material connected electrically in series and thermally in parallel. Heat is applied into one side of the couple and rejected from the opposite side. An electrical current is produced, proportional to the temperature gradient between the hot and cold ...
... a thermocouple, comprising a p-type and n-type material connected electrically in series and thermally in parallel. Heat is applied into one side of the couple and rejected from the opposite side. An electrical current is produced, proportional to the temperature gradient between the hot and cold ...
High-Voltage, High-Current Operational Amplifier (Rev. F
... The OPA547 has thermal shutdown that protects the amplifier from damage. Activation of the thermal shutdown circuit during normal operation is an indication of excessive power dissipation or an inadequate heat sink. Depending on load and signal conditions, the thermal protection circuit may cycle on ...
... The OPA547 has thermal shutdown that protects the amplifier from damage. Activation of the thermal shutdown circuit during normal operation is an indication of excessive power dissipation or an inadequate heat sink. Depending on load and signal conditions, the thermal protection circuit may cycle on ...
Audio Power Amplifier
... RL(parallel) = RL(total) * Number of Amps on IC RL(parallel) = 8 ohms * 2 amps on IC = 16 ohms Pdmax = (Vcc^2)/(2π^2*RL(parallel)) Pdmax = (70V^2)/(2π^2*16 ohms) = 15.51 W Pdmax = 2 * 15.51W = 31.02 W for both amps on IC ...
... RL(parallel) = RL(total) * Number of Amps on IC RL(parallel) = 8 ohms * 2 amps on IC = 16 ohms Pdmax = (Vcc^2)/(2π^2*RL(parallel)) Pdmax = (70V^2)/(2π^2*16 ohms) = 15.51 W Pdmax = 2 * 15.51W = 31.02 W for both amps on IC ...
LM3875.pdf
... heat sink design and the mounting of the IC to the heat sink. For the design of a heat sink for your audio amplifier application refer to the Determining the Correct Heat Sink section. Since a semiconductor manufacturer has no control over which heat sink is used in a particular amplifier design, we ...
... heat sink design and the mounting of the IC to the heat sink. For the design of a heat sink for your audio amplifier application refer to the Determining the Correct Heat Sink section. Since a semiconductor manufacturer has no control over which heat sink is used in a particular amplifier design, we ...
1. Safety Precautions
... instrument. A current equivalent to the primary rated current may flow from the output terminal even when the applied current is stopped. In that case, turn the power switch OFF and then back ON again. Then, the instrument may return to normal once a current of the allowable input range is applied. ...
... instrument. A current equivalent to the primary rated current may flow from the output terminal even when the applied current is stopped. In that case, turn the power switch OFF and then back ON again. Then, the instrument may return to normal once a current of the allowable input range is applied. ...
SML-020MLTT86PN - ROHM Co., Ltd.
... case temperature characteristics for each LED type.) Storage precautions Storage in a dry box is best. However, if this is not possible we recommend the following conditions : Temperature : 5 to 30C Humidity : 60%RH max. Recommended PCB We recommend the following hole diameters. Note, however, th ...
... case temperature characteristics for each LED type.) Storage precautions Storage in a dry box is best. However, if this is not possible we recommend the following conditions : Temperature : 5 to 30C Humidity : 60%RH max. Recommended PCB We recommend the following hole diameters. Note, however, th ...
BFP405F
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
Thermal runaway
Thermal runaway refers to a situation where an increase in temperature changes the conditions in a way that causes a further increase in temperature, often leading to a destructive result. It is a kind of uncontrolled positive feedback.In other words, ""thermal runaway"" describes a process which is accelerated by increased temperature, in turn releasing energy that further increases temperature. In chemistry (and chemical engineering), this risk is associated with strongly exothermic reactions that are accelerated by temperature rise. In electrical engineering, thermal runaway is typically associated with increased current flow and power dissipation, although exothermic chemical reactions can be of concern here too. Thermal runaway can occur in civil engineering, notably when the heat released by large amounts of curing concrete is not controlled. In astrophysics, runaway nuclear fusion reactions in stars can lead to nova and several types of supernova explosions, and also occur as a less dramatic event in the normal evolution of solar mass stars, the ""helium flash"".There are also concerns regarding global warming that a global average increase of 3-4 degrees Celsius above the preindustrial baseline could lead to a further unchecked increase in surface temperatures. For example, releases of methane, a greenhouse gas more potent than CO2, from wetlands, melting permafrost and continental margin seabed clathrate deposits could be subject to positive feedback.