• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Multi-functional Packaged Antennas for Next
Multi-functional Packaged Antennas for Next

Class RM Rectangular Perf 2CFL
Class RM Rectangular Perf 2CFL

... The Corelite R mini combines the lumen package and convenience of a down-light with the volumetric distribution that characterizes the Class R family. The proprietary low-power LED platform developed by Cooper Lighting delivers a soft, diffuse volume of pure white light that carries the general char ...
2014
2014

... (Com. to CE, ME, CHEM, PE, AME, MM) Time: 3 hours ...
STEVAL-PSQ001V1
STEVAL-PSQ001V1

... The industrial standard bus is 24 V, but this voltage fluctuates and the maximum required input voltage level can be up to 36 V. Additional surge protection is also mandatory for power supply input in industrial applications. The purpose of this evaluation board is to address all of required paramet ...
The EM technician role over the last couple years has led each of
The EM technician role over the last couple years has led each of

... below. DC POWER DC current is the unidirectional flow of electrical charge. The associated direct voltages are of unchanging polarity. DC current is produced by such sources as batteries, generators, solar power or thermocouples. It is important to note that DC power will usually only shock a person ...
a high-efficiency mosfet transformerless inverter for
a high-efficiency mosfet transformerless inverter for

... With worldwide growing demand for electric energy, there has been a great interest in exploring photovoltaic (pv) sources. The pv microinverter has become a popular trend for its great flexibility in system installation and expansion, safety of low-input voltage, and high system-level energy harness ...
influence of presowing ion-ozone cavitational processing and air
influence of presowing ion-ozone cavitational processing and air

... cycle the load can be operated as source. In this the circuit will operate as a boost converter which will improve the DC voltage by using isolation transformer and inductor which can be phase shifted. This circuit can operate in two types such as buck and boost operations. In forward operation one ...
Homework 2
Homework 2

... 8. E = 18V. R1 = 9 MΩ. R2 = 1 MΩ. A student uses a voltage divider in hopes of converting 18 V to 2 V, using the circuit shown. When the student connects a cheap volt-ohm meter (VOM) to Vout, she gets just 1.75 V. Explain why the voltage is lower than expected. Note: This problem has nothing to do w ...
Design of Z-Source Inverter for Voltage Boost Application
Design of Z-Source Inverter for Voltage Boost Application

... will be on, either one upper and two lower switches, or two upper and one lower switch. A dead time is given between switching off the upper switch and switching on the lower switch and vice versa. This ensures that both switches are not conductive when they change states from on to off, or vice ver ...
4.21 Arrangement Of Bell Circuits
4.21 Arrangement Of Bell Circuits

... whenever an undesirable event, like short circuit, occurs. These devices are fuses, circuit breakers, and relays; they only operate whenever a high current is detected which exceed their rating. Upon operating they break or interrupt the circuit preventing the current from damaging the protected equ ...
current switch - Carrel Electrade
current switch - Carrel Electrade

... The CR9300 Series is a low cost, self powered, fixed set-point Current Switch designed for applications that require an on-off indication of current flow. Current levels above the guaranteed full-on level will turn the output to full on. The Current Switch is recommended only for applications where ...
Guidelines for Modernizing Existing Electrical
Guidelines for Modernizing Existing Electrical

... switchgear system: passive and active. The passive components include steel frames, cover plates, barriers, and horizontal and vertical bus structures. The active components are more critical and include power circuit breakers or fused devices. These components are responsible for protection from ov ...
High voltage power supplies - Advanced Test Equipment Rentals
High voltage power supplies - Advanced Test Equipment Rentals

... remotely. All parameters can be set and read via the interface and Service Requests can be generated in response to overload or trip conditions. A rear panel switch allows the output voltage to be programmed by an analog input voltage and overrides both front panel and IEEE-488 programming. All thin ...
Parameter Symbol Min. Typ. Max. Unit
Parameter Symbol Min. Typ. Max. Unit

S3 PRACTICAL ELECTRONICS
S3 PRACTICAL ELECTRONICS

... the electricity can not travel around them properly. • None of these circuits are complete, so none of them will work. • Can you see why? ...
Control for Grid Connected Small Wind Turbine System
Control for Grid Connected Small Wind Turbine System

228KB - NZQA
228KB - NZQA

... Voltage across each branch = 12 – 3 = 9.0 V. Current through bottom branch = V / R = 9.0 / 6.0 = 1.5 A Current through middle branch ...
CN0011
CN0011

... It is recommended to decouple close to the device with a 0.1 ?F ceramic and a 10 μF tantalum capacitor. In this circuit, the reference for the AD5382 is provided externally from either an ADR421 or ADR431 2.5 V reference. The ADR431 provides a ...
KST2222A KST2222A  NPN Epit axial Silicon T ransistor
KST2222A KST2222A NPN Epit axial Silicon T ransistor

... or sustain life, or (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. ...
6.3.1 worksheet - Digilent Learn site
6.3.1 worksheet - Digilent Learn site

... 4. Attach to this worksheet an image of the oscilloscope window, showing the capacitor voltage and current waveforms and the measured amplitudes of the waveforms for a 100Hz triangular input. (8 pts) ...
The Two-Phase, Full-Wave Rectifier
The Two-Phase, Full-Wave Rectifier

penetration level assessment of distributed generation
penetration level assessment of distributed generation

Solution
Solution

... (b) Calculate the voltage regulation of this transformer for a full-load current at power factor of 0.8 lagging. (c) Assume that the primary voltage of this transformer is a constant 15 kV, and plot the secondary voltage as a function of load current for currents from no load to full load. Repeat th ...
Definition Crest Factor - AMETEK Programmable Power
Definition Crest Factor - AMETEK Programmable Power

... Since the same rms current level is drawn in both examples, the true power provided would be the same for both (if the voltage were held at a constant level for both examples). This means that a power source selected to feed the loads at 120VAC would need to provide the 600VA that both loads require ...
2SC4793
2SC4793

... • TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOS ...
< 1 ... 839 840 841 842 843 844 845 846 847 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report