• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
high step-up interleaved forward-flyback boost
high step-up interleaved forward-flyback boost

Compensation Methods in Voltage Regulators | CUI Inc
Compensation Methods in Voltage Regulators | CUI Inc

... process. It is common that the wrong value of a compensation component is installed, another part of the circuit is accidently modified, or the circuit board is damaged during the design process. It is also possible that the circuits drawing power from the voltage regulator can become damaged due to ...
PPT EN version
PPT EN version

... » Unearthed accessible conductive parts shall be assumed to be connected to an earth terminal » Floating circuit assumed to be connected to an earth terminal at the point which results in the highest working voltage being obtained; » Double insulation: short-circuit across on of the insulation when ...
WECC PV PLant Power Flow Modeling Guidelines
WECC PV PLant Power Flow Modeling Guidelines

... large PV systems are still evolving. Distribution-connected PV systems at generally operated at unity power factor over their entire active power output range. Most inverters designed for residential and commercial applications are not sized to provide any reactive current at full output. However, P ...
V to
V to

... intended to have large impedances for the dc signal and very small impedances for the ac signal. ...
Low Cost, High Power Factor, Dimmable, Monolithic AC
Low Cost, High Power Factor, Dimmable, Monolithic AC

... A. System Design and Fundamental Operation As depicted in Fig. 1, the proposed dimmable AC-direct LED driver consists of a bridge, a self-adaptive power processing circuit based on the design reported in [6] that drives multiple LED strings directly from the AC mains, a start-up circuit, a low volta ...
6.302 Feedback Systems
6.302 Feedback Systems

... In the waveform that you just analyzed, the parameter “D” is called the duty cycle. Modulating, or changing, the duty cycle in order to achieve a certain DC value is a common control technique. It is called pulse width modulation, or PWM. One of the places PWM is useful is in voltage conversion. Oft ...
EPC9047 Quick Start Guide - Efficient Power Conversion
EPC9047 Quick Start Guide - Efficient Power Conversion

... simplify the evaluation process of these eGaN FETs by including all the critical components on a single board that can be easily connected into any existing converter. The development board is 2” x 1.5” and contains two eGaN FETs in a half bridge configuration using the Texas Instruments UCC27611 ga ...
ABWR 8.2  Offsite Power Systems 8.2.1  Description
ABWR 8.2 Offsite Power Systems 8.2.1 Description

... the generator to be taken offline and the offsite transmission network to be utilized as a power source by backfeeding to the unit auxiliary transformers and their loads, both Class 1E and nonClass 1E. This is also the startup power source for the unit. Short circuit analysis will be performed in ac ...
Integrated Sequence of Operations: Coordinating ATS and UPS Set
Integrated Sequence of Operations: Coordinating ATS and UPS Set

... (UPS, generator, ATS). Consider it re-commissioning a subset of your data center around new equipment. For older equipment, you would be adjusting an inaccurate mechanical potentiometer. Now with most of the new units, you can calibrate the component voltage within a single volt or tenth of a hertz. ...


... Voltage stability is an important factor to be considered in power system operation and planning since voltage instability would lead to system collapse. The problem of voltage stability [1] has been defined as inability of the power system to provide the reactive power [2] or non-uniform consumptio ...
ROLE OF VACUUM GENERATOR CIRCUIT BREAKER IN
ROLE OF VACUUM GENERATOR CIRCUIT BREAKER IN

... and 100 V respectively are used and the arcing times are reduced to 62 ms, 45 ms & 29 ms respectively. In some cases, an intentional delay up to 150 ms in the tripping circuit is used so that the DC component at the time of the contact separation reaches to a value that the circuit breaker will be a ...
Le 220 DE Control
Le 220 DE Control

... This new preamplifier perpetuates all the values which have established the reputation of the Control "B," adding some refinements in relation to the permanent search for more precise, more stable, more musical components. All circuits are modular. Each printed circuit is dedicated to a unique funct ...
vertical power strips
vertical power strips

... Vertical Power Strips attach to the rear of the rack to save rack-mount spaces for equipment. Several power strips can be attached to a rack by using optional Offset Mounting Brackets to supply multiple circuits in support of redundant power. Power strips equipped with circuit breakers and surge-pro ...
DUAL LOW-NOISE OPERATIONAL AMPLIFIERS
DUAL LOW-NOISE OPERATIONAL AMPLIFIERS

... Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C NOTES: 1. All vol ...
SUNNY TRIPOWER 12000TL-US/15000TL-US/20000TL
SUNNY TRIPOWER 12000TL-US/15000TL-US/20000TL

... future-proof solution with full grid management, and communications and monitoring features. The Sunny Tripower is also equipped with all-pole ground fault protection and integrated AFCI for a safe, reliable solution. It offers unmatched flexibility with a wide input voltage range and two independen ...
South Pasadena · AP Chemistry
South Pasadena · AP Chemistry

... a) what shape would the graph have for direct current from a battery? b) what shape would the graph have for alternating current from an outlet? ...
Reduced Power Electronic Componets Using a New Cascade
Reduced Power Electronic Componets Using a New Cascade

... hand, this inverter consists of a number of basic blocks (sub multilevel inverter) that each of these blocks has similar control system. One of the major advantages of this type of inverters is the ability of its modulation. So, if an error occurs in one of the blocks, it can replace or fix by using ...
17th Edition (BS 7671:2008) incorporating Amendment No 1
17th Edition (BS 7671:2008) incorporating Amendment No 1

... The natural protection of the human body is considerably reduced when certain clinical procedures are being performed on it. Patients under treatment may have their skin resistance broken or their defensive capacity either reduced by medication or nullified while anaesthetised. These conditions incr ...
Using Standard Control ICs to Generate Negative Gate Bias
Using Standard Control ICs to Generate Negative Gate Bias

... supply voltage to the IR211 0 cannot exceed 20V. The 100k resistor is sufficient for HV = 160V, 50% duty cycle operation. Different operating conditions may require different resistor values. The average current through the resistor should be at least 1 rnA. The power handling capability and maximum ...
Multiple-Output: 40 W-105 W GPIB
Multiple-Output: 40 W-105 W GPIB

... Transient response time Less than 75 µs for the output to recover to within 75 mV of nominal value following ...
G-Eye Extending your monitoring & control capabilities
G-Eye Extending your monitoring & control capabilities

... Extreme environmental changes can dramatically affect the operating capabilities of electrical systems. G-Eye solution: The unit accepts input from multiple temperature sensors, enabling real-time monitoring of temperatures at a number of sites. Alarm thresholds (high and low) can be custom configur ...
Poster4x8_uc02
Poster4x8_uc02

BP5510-24
BP5510-24

Power supply require..
Power supply require..

... supplied to the MMIC exhibits a large drop before it reaches the actual transistors. This voltage drop is caused by on-chip resistors and is of course dependent on the current (Id), which is a strong function of the physical temperature. At room temperature the transistors seems to give lowest noise ...
< 1 ... 822 823 824 825 826 827 828 829 830 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report