MAX17409 Evaluation Kit Evaluates: General Description Features
... an abusive-load transient is to install a power MOSFET at the N4 location and install resistor R14 between 5mω and 10mω to monitor the transient current. Then drive its gate (TP1) with a strong pulse generator at a low duty cycle (< 5%) to minimize heat stress in the MOSFET. Vary the high-level outp ...
... an abusive-load transient is to install a power MOSFET at the N4 location and install resistor R14 between 5mω and 10mω to monitor the transient current. Then drive its gate (TP1) with a strong pulse generator at a low duty cycle (< 5%) to minimize heat stress in the MOSFET. Vary the high-level outp ...
Investigation of Solar PV Inverters Current Contributions during
... downstream distribution stations (DS), reclosers, and lower voltage distribution feeders to represent the system levels that supply typical end-user customers and where PV installations may be found. The transmission and distribution system includes modeling details, such as transformer winding conf ...
... downstream distribution stations (DS), reclosers, and lower voltage distribution feeders to represent the system levels that supply typical end-user customers and where PV installations may be found. The transmission and distribution system includes modeling details, such as transformer winding conf ...
Stacked_Switches_MJB_V1
... following a BD [trigger to switch-on is increased in duration for 3 µs from the instant of a BD – but a turn-off command can have been sent ≤200 ns before the BD …..]. Limitations – no active pull down at present (23 µs fall time-constant 250 ns to 99%: 0.9930=0.74); system could be modified to ...
... following a BD [trigger to switch-on is increased in duration for 3 µs from the instant of a BD – but a turn-off command can have been sent ≤200 ns before the BD …..]. Limitations – no active pull down at present (23 µs fall time-constant 250 ns to 99%: 0.9930=0.74); system could be modified to ...
MAX4141 330MHz, 4x1 Precision Video Multiplexer
... for a frequency greater than 1GHz. Even with very short runs, it’s good practice to use this technique at critical points, such as inputs and outputs. Whether you use a constant-impedance board or not, observe the following guidelines when designing the board: • Do not use wire-wrap boards, because ...
... for a frequency greater than 1GHz. Even with very short runs, it’s good practice to use this technique at critical points, such as inputs and outputs. Whether you use a constant-impedance board or not, observe the following guidelines when designing the board: • Do not use wire-wrap boards, because ...
GS2613561363
... transformers. The advantages of the converter side filters are (a) the components are rated at lower voltage and (b) higher order harmonic currents (due to the VSC) do not °own through the transformer windings. The disadvantages are that the filter inductor causes voltage drop and phase (angle) shif ...
... transformers. The advantages of the converter side filters are (a) the components are rated at lower voltage and (b) higher order harmonic currents (due to the VSC) do not °own through the transformer windings. The disadvantages are that the filter inductor causes voltage drop and phase (angle) shif ...
Voltage Regulators from Siemens
... 1.1 This specification covers electrical, mechanical and safety features and characteristics of outdoor, three phase, oil immersed, 50 or 60 Hz 55/65oC temperature rise by resistance, self cooled and force-air cooled step-type voltage regulators. The voltage regulators must be completely self-contai ...
... 1.1 This specification covers electrical, mechanical and safety features and characteristics of outdoor, three phase, oil immersed, 50 or 60 Hz 55/65oC temperature rise by resistance, self cooled and force-air cooled step-type voltage regulators. The voltage regulators must be completely self-contai ...
45 MHz Test Model - Brounley RF, Inc.
... drain waveform consistent with a high-efficiency amplifier. The drain waveforms and frequency spectrum are shown in the pictures of Figures 12, 13 and 14 and will be discussed in more detail later. The tests results of the model are shown in Figure 2. The input and output circuits use a two-step mat ...
... drain waveform consistent with a high-efficiency amplifier. The drain waveforms and frequency spectrum are shown in the pictures of Figures 12, 13 and 14 and will be discussed in more detail later. The tests results of the model are shown in Figure 2. The input and output circuits use a two-step mat ...
Slide Title Goes Here
... • Each card has access to the full power supply current via the backplane in event of a fault • Mitigations • Current limiting feature in voltage regulators • PolyFuse protection at point of entry Polymeric positive temperature coefficient device for overcurrent and overtemperature protection Resett ...
... • Each card has access to the full power supply current via the backplane in event of a fault • Mitigations • Current limiting feature in voltage regulators • PolyFuse protection at point of entry Polymeric positive temperature coefficient device for overcurrent and overtemperature protection Resett ...
NESDAC - University of Utah
... Regulate a low-current common voltage for communication standardization Filter power locally (battery and 3.3v) to reduce inrush current spikes from propagating back over the bus Microcontroller can monitor battery voltage Use CR2’s or 2/3AA batteries ...
... Regulate a low-current common voltage for communication standardization Filter power locally (battery and 3.3v) to reduce inrush current spikes from propagating back over the bus Microcontroller can monitor battery voltage Use CR2’s or 2/3AA batteries ...
HMC586LC4B
... Voltage Controlled Oscillator which incorporates the resonator, negative resistance device, and varactor diode. Output power and phase noise performance are excellent over temperature due to the oscillator’s monolithic construction. The Vtune port accepts an analog tuning voltage from 0 to +18V. The ...
... Voltage Controlled Oscillator which incorporates the resonator, negative resistance device, and varactor diode. Output power and phase noise performance are excellent over temperature due to the oscillator’s monolithic construction. The Vtune port accepts an analog tuning voltage from 0 to +18V. The ...
8 Bit Digital-to-Analog Converter
... when the input changes from “00000000” to “11111111”. Since the output voltage only has to be within half of the lsb’s step size from the positive rail voltage, 2.8 volts is used. This test can be seen in figure 1. Once the settling time is found, the maximum frequency can be easily calculated. By c ...
... when the input changes from “00000000” to “11111111”. Since the output voltage only has to be within half of the lsb’s step size from the positive rail voltage, 2.8 volts is used. This test can be seen in figure 1. Once the settling time is found, the maximum frequency can be easily calculated. By c ...
Aalborg Universitet Voltage Ride-Through Mode
... that the future PV system will have ancillary functions (e.g., low voltage ride through (LVRT) under grid faults) and it will have to be more reliable and more “smart” [5]-[11]. Normally, the reliability of a PV system can be increased by means of proper component selection (considering rated power ...
... that the future PV system will have ancillary functions (e.g., low voltage ride through (LVRT) under grid faults) and it will have to be more reliable and more “smart” [5]-[11]. Normally, the reliability of a PV system can be increased by means of proper component selection (considering rated power ...
PDF
... The switchpack has two main components: a transformer and one high current relay. The transformer has a primary line voltage input and a secondary low voltage output. The low voltage output, 15 VDC, provides operating power to connected low voltage Greengate occupancy sensors. When an occupancy sens ...
... The switchpack has two main components: a transformer and one high current relay. The transformer has a primary line voltage input and a secondary low voltage output. The low voltage output, 15 VDC, provides operating power to connected low voltage Greengate occupancy sensors. When an occupancy sens ...
B59884C0120A054 Datasheet
... with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in ...
... with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in ...
RF5355 3.3V, 5GHz LINEAR POWER AMPLIFIER Features
... The RF5355 requires only a single positive supply of 3.3V nominal (or greater) to operate to full specifications. Power control is provided through one bias pin, VREG. The three bias voltages for the three stages are connected together on the die and only one bias control voltage is needed (VREG). T ...
... The RF5355 requires only a single positive supply of 3.3V nominal (or greater) to operate to full specifications. Power control is provided through one bias pin, VREG. The three bias voltages for the three stages are connected together on the die and only one bias control voltage is needed (VREG). T ...
Chapter 5: Diodes I. Theory
... Current cannot flow the other way, since there is no energy source to create holes and electrons. ...
... Current cannot flow the other way, since there is no energy source to create holes and electrons. ...
Single Schottky Barrier Diode, 30 V, 3 A
... rise to smoke or fire, or accidents that could cause damage to other property. When designing equipment, adopt safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redu ...
... rise to smoke or fire, or accidents that could cause damage to other property. When designing equipment, adopt safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redu ...
DC-DC Converters for Space
... and radiation-tolerant space products includes FPGAs, ASICs, RF components, diodes, transistors, MOSFETS, hybrids, power supplies, custom semiconductor packaging and integrated power distribution systems. Microsemi's radiation hardened analog/mixed-signal ICs and power modules/hybrids provide effici ...
... and radiation-tolerant space products includes FPGAs, ASICs, RF components, diodes, transistors, MOSFETS, hybrids, power supplies, custom semiconductor packaging and integrated power distribution systems. Microsemi's radiation hardened analog/mixed-signal ICs and power modules/hybrids provide effici ...
Stray voltage
... Competent stray voltage investigations require a considerable level of skill and electrical knowledge so don’t be afraid to enlist help if required. This is not to say that stray voltage detection and correction is a “Black Art” known only to a select few. Perhaps 99% of stray voltage problems can b ...
... Competent stray voltage investigations require a considerable level of skill and electrical knowledge so don’t be afraid to enlist help if required. This is not to say that stray voltage detection and correction is a “Black Art” known only to a select few. Perhaps 99% of stray voltage problems can b ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.