• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AC voltage relays bulletin
AC voltage relays bulletin

POWER FACTOR TESTING WHAT IS IT ?
POWER FACTOR TESTING WHAT IS IT ?

... erroneous readings in excitation current measurements.  IEEE C57.152 section 7.211.1 states that “The transformer core may have residual magnetism present as a result of being disconnected from the power line or, as is frequently the case, as a result of dc measurements of winding resistance. The r ...
Dynamic Load Modelling of Some Low Voltage
Dynamic Load Modelling of Some Low Voltage

... The paper presents some of the results of numerous laboratory tests on representatives of most frequently used low voltage devices in order to model long-term dynamic performance of these devices. It is found that exponential dynamic load model is adequate because maximum deviation of measured power ...
vega heatsink slide dimmer
vega heatsink slide dimmer

Frequently Asked Questions
Frequently Asked Questions

... generate heat, causing a temperature rise in the unit. These losses cannot be eliminated and must be controlled by proper design and correct application to prevent overheating of the transfo rmer. Underwriters Laboratories standards dictate maximum temperat ure limits for neon transformers. 3.008 Wh ...
Power Supply Restoration
Power Supply Restoration

Microcontroller Based PWM Controlled Four Switch Three Phase
Microcontroller Based PWM Controlled Four Switch Three Phase

... microcontroller are fed to the gate of MOSFETs of FSTPI through the driver circuit to drive the IM. 2.1 Principle of FSTPI operation The power circuit of the FSTPI fed IM drive is shown in Fig. 1. The circuit consists of 4-switches S1 , S 2 , S3 and S 4 and split capacitors C1 and C2 . The 3-phase A ...


IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

Final Presentation - High Speed Digital Systems Lab
Final Presentation - High Speed Digital Systems Lab

... instead of Boost converter to prevent possible noises and to reduce BOM price. Because we can’t trust that the USB power is always +5v and not less, we couldn’t use only one charge pump to double it, so we needed two charge pumps with more than +5v operating voltage range. We found only one charge p ...
1 Scope - Duke Atlas
1 Scope - Duke Atlas

... fiber bundles. Stray fiber bundles in a position near the shell or an adjacent high voltage group can cause a high voltage breakdown. This test will identify damaged straws and allow straw replacement or fiber bundle repair before the straws are glued into place. Before straw gluing, test all high v ...
Ohm`s Law - MSU Physics
Ohm`s Law - MSU Physics

B o o s t   C o n... TDA4863 Power Factor Controller IC for High Power Factor
B o o s t C o n... TDA4863 Power Factor Controller IC for High Power Factor

... bridge rectifier and a bulk capacitor. Their disadvantage is that the circuit draws power from the line when the instantaneous AC voltage exceeds the capacitors voltage. This occurs near the line voltage peak and causes a high charge current spike with following characteristics: The apparent power i ...
Modulating Functions of Space Vector PWM for Three-Leg VSI
Modulating Functions of Space Vector PWM for Three-Leg VSI

High Efficiency NPC Multilevel Converters using Super
High Efficiency NPC Multilevel Converters using Super

... Whilst the currents in TR2 and TR3 are zero when they are turned off, a voltage change of Vss/2 is applied across one of them during each switching cycle. This results in them drawing Coss charging currents to supply Qoss. As described in [1], SJ MOSFETs have a highly non-linear Coss. In [17], a sim ...
Electronic Scale - SJSU Engineering
Electronic Scale - SJSU Engineering

... with op-amps designed for small signal amplification. There are also power op-amps that are designed to source or sink relatively large currents at relatively high voltages. Small-signal single op-amp IC’s are usually pin-compatible with the ‘741, but one should always check the data sheets to be su ...
LC044
LC044

TPS2490, Reverse Input Voltage Block
TPS2490, Reverse Input Voltage Block

... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
Care and Repair of MCI JH Series Transports
Care and Repair of MCI JH Series Transports

EW22912916
EW22912916

For ConTech Lighting Magellan Low Voltage Flexible Track System
For ConTech Lighting Magellan Low Voltage Flexible Track System

... Layout the Magellan design on the floor and connect the tracks together. Align the mounting points on the ceiling using a plumb line or laser device. Install all the support stems and power connections on the ceiling. Starting at the power connections, begin with a single Magellan track piece and at ...
Illuminator E Specs - Myers Power Products
Illuminator E Specs - Myers Power Products

CP35508515
CP35508515

... second controller has a greater impact on the performance of single-stage PFC converters and requires a design to operate over a much wider range of operating conditions. For the proposed voltage controlled drive, a half-bridge Buck DC-DC converter is selected because of its high power handling capa ...
LINEARITY ANALYSIS OF SPLIT SAR ADC
LINEARITY ANALYSIS OF SPLIT SAR ADC

... pipeline, two-step, or sub ranging schemes. The basic structure blocks are the track-and-hold, the comparator, and the op-amp. Its key drawback lies in the parasitic capacitors that demolish the desired dual ratio of the capacitive DAC array, thus corrupting the conversion linearity. The competitive ...
CMD234C4 - Custom MMIC
CMD234C4 - Custom MMIC

... Functional Block Diagram ...
< 1 ... 618 619 620 621 622 623 624 625 626 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report