Datasheet
... 4. PAD BURR LENGTH SHALL BE 0.15mm MAXIMUM. PAD BURR HEIGHT SHALL BE 0.05mm MAXIMUM. 5. PACKAGE WARP SHALL NOT EXCEED 0.05mm. ...
... 4. PAD BURR LENGTH SHALL BE 0.15mm MAXIMUM. PAD BURR HEIGHT SHALL BE 0.05mm MAXIMUM. 5. PACKAGE WARP SHALL NOT EXCEED 0.05mm. ...
$doc.title
... data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. Motorola does not convey any license under its patent ...
... data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. Motorola does not convey any license under its patent ...
Speed-up charge pump circuit to improve lock time for integer
... trol circuit is disconnected from the input terminal. 2. The system of claim 1 Wherein said circuitry includes a sWitch coupled to said input terminal, a charge pump coupled to said sWitch and remote from said input terminal and a timer controlling the current output of said charge pump and said sWi ...
... trol circuit is disconnected from the input terminal. 2. The system of claim 1 Wherein said circuitry includes a sWitch coupled to said input terminal, a charge pump coupled to said sWitch and remote from said input terminal and a timer controlling the current output of said charge pump and said sWi ...
Light dimmer circuits
... heatsink, the maximum available power from the circuit is around 300W. The coil L1 must be able to withstand continuous current of at least 4.5A and it can have any value between 40 and 100 microhenries. For C1 I would recommend a good quality 150 nanofarad capacitor designed for mains power applica ...
... heatsink, the maximum available power from the circuit is around 300W. The coil L1 must be able to withstand continuous current of at least 4.5A and it can have any value between 40 and 100 microhenries. For C1 I would recommend a good quality 150 nanofarad capacitor designed for mains power applica ...
Specification Number: 16440-1
... form a rigid free standing unit. Minimum sheet metal thickness shall be 11 gauge steel on all exterior surfaces. Unit shall be braced to prevent distortion. B. Torque bolts that are used for insulators and direct support of any current carrying parts shall be marked with a bead of highly visiblebrig ...
... form a rigid free standing unit. Minimum sheet metal thickness shall be 11 gauge steel on all exterior surfaces. Unit shall be braced to prevent distortion. B. Torque bolts that are used for insulators and direct support of any current carrying parts shall be marked with a bead of highly visiblebrig ...
please do not remove this page
... As PCD is a relatively low bulk conductivity material, the discharging characteristics of PCD are different from conventional materials such as carbide and High Speed Steel (HSS) [5]. Theoretically high voltage, smaller current and high frequency (short On-Time) should be applied to achieve better s ...
... As PCD is a relatively low bulk conductivity material, the discharging characteristics of PCD are different from conventional materials such as carbide and High Speed Steel (HSS) [5]. Theoretically high voltage, smaller current and high frequency (short On-Time) should be applied to achieve better s ...
industrial accelerometers
... normalize after the shock of mounting it. This is known as settling time. The time it takes for the amplifier circuit to stabilize and settle after temporarily mounting it is very dependent on the mounting process. If the accelerometer is mounted harshly on the machine by letting the magnet mount sn ...
... normalize after the shock of mounting it. This is known as settling time. The time it takes for the amplifier circuit to stabilize and settle after temporarily mounting it is very dependent on the mounting process. If the accelerometer is mounted harshly on the machine by letting the magnet mount sn ...
HDE Short Form Product Catalog
... Thank you for your interest in HDE and our products. Our continuous improvement and innovation in the areas of controlling, testing, measuring and recording of electric power has resulted in the development of leading edge products designed to help you provide electric power to your customers safely ...
... Thank you for your interest in HDE and our products. Our continuous improvement and innovation in the areas of controlling, testing, measuring and recording of electric power has resulted in the development of leading edge products designed to help you provide electric power to your customers safely ...
THIRD CHAPTER INSTALLATION
... Consultants must prevent voltage surges causes in the electrical circuit and undertake suitable actions, using voltage peaks erasers devices. Most common reason for voltage surges is circuit switch off when voltage sinwave is at maximum value. This effect is much more possible if: • nominal frequenc ...
... Consultants must prevent voltage surges causes in the electrical circuit and undertake suitable actions, using voltage peaks erasers devices. Most common reason for voltage surges is circuit switch off when voltage sinwave is at maximum value. This effect is much more possible if: • nominal frequenc ...
SN65LVDM051-Q1 数据资料 dataSheet 下载
... Voltage range (Y, Z, A, and B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 4 V Electrostatic discharge: Y, Z, A, B , and GND (see Note 2) . . . . . . . . . . . . . . . . . . CLass 3, A:12 kV, B:600 V All . . . . . . . . . . ...
... Voltage range (Y, Z, A, and B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 4 V Electrostatic discharge: Y, Z, A, B , and GND (see Note 2) . . . . . . . . . . . . . . . . . . CLass 3, A:12 kV, B:600 V All . . . . . . . . . . ...
Switching, Operation/ Display and Control Devices
... Current Status and Future Outlook for Electric Distribution and Control Devices ...
... Current Status and Future Outlook for Electric Distribution and Control Devices ...
TC75S54F, TC75S54FU, TC75S54FE
... • This document and any information herein may not be reproduced without prior written permission from TOSHIBA. Even with TOSHIBA's written permission, reproduction is permissible only if reproduction is without alteration/omission. • Though TOSHIBA works continually to improve Product's quality and ...
... • This document and any information herein may not be reproduced without prior written permission from TOSHIBA. Even with TOSHIBA's written permission, reproduction is permissible only if reproduction is without alteration/omission. • Though TOSHIBA works continually to improve Product's quality and ...
Unit 4 PowerPoint Slides
... meshes. Apply KVL to each of the n meshes. Use Ohm’s law to express the voltages in terms of mesh currents. Then simplify the ...
... meshes. Apply KVL to each of the n meshes. Use Ohm’s law to express the voltages in terms of mesh currents. Then simplify the ...
Application Examples
... V IL 0.8 V R L < ------- = ------------------- = 500 Ω 1.6 mA I IL A voltage VL at RL resistor of VIH ≥ 2 V is necessary in order to attain a safe high state at the output. This needs to be generated by the collector current IC of the phototransistor. In the case of the TTL output at the input of th ...
... V IL 0.8 V R L < ------- = ------------------- = 500 Ω 1.6 mA I IL A voltage VL at RL resistor of VIH ≥ 2 V is necessary in order to attain a safe high state at the output. This needs to be generated by the collector current IC of the phototransistor. In the case of the TTL output at the input of th ...
AP358 LOW POWER DUAL OPERATIONAL AMPLIFIERS Description
... capability of the basic amplifiers. The output voltage needs to raise approximately 1 diode drop above ground to bias the on-chip vertical PNP transistor for output current sinking applications. For ac applications, where the load is capacitively coupled to the output of the amplifier, a resistor sh ...
... capability of the basic amplifiers. The output voltage needs to raise approximately 1 diode drop above ground to bias the on-chip vertical PNP transistor for output current sinking applications. For ac applications, where the load is capacitively coupled to the output of the amplifier, a resistor sh ...
High Voltage Power Supply Technology for Use in Power Feed
... best transistor technology to use). High Voltage step-up Transformer: The high frequency ac power source is connected to a transformer with a high step-up ratio. In PFE applications, the transformer secondary winding needs to be isolated to voltages up to and greater than the output voltage rating o ...
... best transistor technology to use). High Voltage step-up Transformer: The high frequency ac power source is connected to a transformer with a high step-up ratio. In PFE applications, the transformer secondary winding needs to be isolated to voltages up to and greater than the output voltage rating o ...
RT7275/76 - Richtek Technology
... arrangement has high noise immunity and is ideal for low duty cycle applications. After the on-time one-shot period, there is a minimum off-time period before any further regulation decisions can be considered. This arrangement avoids the need to make any decisions during the noisy time periods just ...
... arrangement has high noise immunity and is ideal for low duty cycle applications. After the on-time one-shot period, there is a minimum off-time period before any further regulation decisions can be considered. This arrangement avoids the need to make any decisions during the noisy time periods just ...
User`s Manual CPS1000E-DE
... operate your Emergency Power System (EPS). CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (Please see specifications for acceptable temperature and humidity range). CAUTION! To reduce the risk of e ...
... operate your Emergency Power System (EPS). CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (Please see specifications for acceptable temperature and humidity range). CAUTION! To reduce the risk of e ...
VISHAY IL300 datasheet
... In applications such as monitoring the output voltage from a line powered switch mode power supply, measuring bioelectric signals, interfacing to industrial transducers, or making floating current measurements, a galvanically isolated, DC coupled interface is often essential. The IL300 can be used t ...
... In applications such as monitoring the output voltage from a line powered switch mode power supply, measuring bioelectric signals, interfacing to industrial transducers, or making floating current measurements, a galvanically isolated, DC coupled interface is often essential. The IL300 can be used t ...
C1388C (X3)
... Key PWR(Power)- Battery voltage that is recieved, via the ignition switch when the key is placed in the ON position. MPR- FICM Main power relay control output from FICM. SYNC- SYNC is achieved when the PCM receives a signal from the crankshaft sensor and camshaft sensor indicating they are working a ...
... Key PWR(Power)- Battery voltage that is recieved, via the ignition switch when the key is placed in the ON position. MPR- FICM Main power relay control output from FICM. SYNC- SYNC is achieved when the PCM receives a signal from the crankshaft sensor and camshaft sensor indicating they are working a ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.