LT3592 - 500mA Wide Input Voltage Range Step
... RT (Pin 1): Programs the frequency of the internal oscillator. Connect a resistor from RT to ground. Refer to Table 1 or the Typical Performance Characteristics for resistor values that result in desired oscillator frequencies. BRIGHT (Pin 2): Used to program a 10:1 dimming ratio for the LED current ...
... RT (Pin 1): Programs the frequency of the internal oscillator. Connect a resistor from RT to ground. Refer to Table 1 or the Typical Performance Characteristics for resistor values that result in desired oscillator frequencies. BRIGHT (Pin 2): Used to program a 10:1 dimming ratio for the LED current ...
NX5P1000 1. General description Logic controlled high-side power switch
... The overall Rth(j-a) can vary depending on the board layout. To minimize the effective Rth(j-a), all pins must have a solid connection to larger Cu layer areas e.g. to the power and ground layer. In multi-layer PCB applications, the second layer should be used to create a large heat spreader area ri ...
... The overall Rth(j-a) can vary depending on the board layout. To minimize the effective Rth(j-a), all pins must have a solid connection to larger Cu layer areas e.g. to the power and ground layer. In multi-layer PCB applications, the second layer should be used to create a large heat spreader area ri ...
Minariks DC Drives - XP-DC Series - User Manual
... batteries, especially lead-acid type. This manual presupposes that you have taken all the necessary precautions to prevent a potentially fatal accident involving such batteries, and have followed all standard electrical precautions. ...
... batteries, especially lead-acid type. This manual presupposes that you have taken all the necessary precautions to prevent a potentially fatal accident involving such batteries, and have followed all standard electrical precautions. ...
BD6385EFV-LB
... An excess in the absolute maximum ratings, such as supply voltage, temperature range of operating conditions, etc., can break down the devices, thus making impossible to identify breaking mode, such as a short circuit or an open circuit. If any over rated values will expect to exceed the absolute ma ...
... An excess in the absolute maximum ratings, such as supply voltage, temperature range of operating conditions, etc., can break down the devices, thus making impossible to identify breaking mode, such as a short circuit or an open circuit. If any over rated values will expect to exceed the absolute ma ...
The Rechargeable Battery “Cycler”
... The second tab is where you set the battery parameters, such as the battery capacity, the number of cells, the end of discharge voltage threshold, the discharge current, the charge current and the charge duration. These parameters are individually set for both batteries. Charge and discharge paramet ...
... The second tab is where you set the battery parameters, such as the battery capacity, the number of cells, the end of discharge voltage threshold, the discharge current, the charge current and the charge duration. These parameters are individually set for both batteries. Charge and discharge paramet ...
Stability and dynamic performance of current
... ensure equal load-current distribution among the modules for both steady state and transient load conditions. A good dynamic performance of the CS circuit is very important since the microprocessors present a highly dynamic load for the VRMs. To meet the requirements of high power density and fast t ...
... ensure equal load-current distribution among the modules for both steady state and transient load conditions. A good dynamic performance of the CS circuit is very important since the microprocessors present a highly dynamic load for the VRMs. To meet the requirements of high power density and fast t ...
General Description Features and Benefits
... The MAX15068 offers ORing function and hot-swap features for two input-supply-rail applications requiring the safe insertion and removal of circuit line cards from a live backplane. The device integrates dual ORing MOSFET controllers, a single hot-swap controller, electronic circuitbreaker protectio ...
... The MAX15068 offers ORing function and hot-swap features for two input-supply-rail applications requiring the safe insertion and removal of circuit line cards from a live backplane. The device integrates dual ORing MOSFET controllers, a single hot-swap controller, electronic circuitbreaker protectio ...
with respect to ground
... Raceway may not be a straight run between devices as but there may be elbows or pull elbows along the way. The cable could been stretched over a sharp edge inside the conduit hardware that cut into cable and wire insulation ‣ Bringing wire into electrical contact with the conduit ground path. Care m ...
... Raceway may not be a straight run between devices as but there may be elbows or pull elbows along the way. The cable could been stretched over a sharp edge inside the conduit hardware that cut into cable and wire insulation ‣ Bringing wire into electrical contact with the conduit ground path. Care m ...
AI34212218
... important than it is today. In industrialized countries, about 70% of all of the generated electric energy is used by electrical motors. In addition, more than 60% of all the electric energy converted into mechanical energy is consumed by pump and fan drives with induction motors. This fact points o ...
... important than it is today. In industrialized countries, about 70% of all of the generated electric energy is used by electrical motors. In addition, more than 60% of all the electric energy converted into mechanical energy is consumed by pump and fan drives with induction motors. This fact points o ...
Low-Drift, Low-Power, Dual-Output, VREF and VREF / 2 Voltage
... (8 ppm/°C, max) and initial accuracy (0.05%) on both the VREF and VBIAS outputs while operating at a quiescent current less than 430 µA. In addition, the VREF and VBIAS outputs track each other with a precision of 6 ppm/°C (max) across the temperature range of –40°C to 85°C. All these features incre ...
... (8 ppm/°C, max) and initial accuracy (0.05%) on both the VREF and VBIAS outputs while operating at a quiescent current less than 430 µA. In addition, the VREF and VBIAS outputs track each other with a precision of 6 ppm/°C (max) across the temperature range of –40°C to 85°C. All these features incre ...
The Evaluation of Steel Conduit and EMT as Equipment
... coordinated to permit the circuitprotective devices used to clear a fault to do so without extensive damage to the electrical component (equipment) of the circuit”. . . ...
... coordinated to permit the circuitprotective devices used to clear a fault to do so without extensive damage to the electrical component (equipment) of the circuit”. . . ...
MAX1838 Dual USB Switch with Fault Blanking and Autoreset General Description
... Power Input. Connect both IN pins together and bypass with a 0.1µF capacitor to GND. Load conditions may require additional bulk capacitance to maintain the IN voltage regulation. ...
... Power Input. Connect both IN pins together and bypass with a 0.1µF capacitor to GND. Load conditions may require additional bulk capacitance to maintain the IN voltage regulation. ...
Slide 1
... stations antennas, terminal equipments, interfacing with ground network etc. INTELSAT, INSAT, MOLNIYA and other typical systems, satellite broadcasting- basic principles, Remote sensing basic principles. ...
... stations antennas, terminal equipments, interfacing with ground network etc. INTELSAT, INSAT, MOLNIYA and other typical systems, satellite broadcasting- basic principles, Remote sensing basic principles. ...
Rotary Phase Converters
... converter, plus the KVA required to accommodate any additional single-phase loads that may be also connected to the transformer. What fuse and wire sizes are required for installation? Full load current of the ROTO-CON® and ROTOVERTER® is noted on the converter nameplate (approximately 4.5 amps per ...
... converter, plus the KVA required to accommodate any additional single-phase loads that may be also connected to the transformer. What fuse and wire sizes are required for installation? Full load current of the ROTO-CON® and ROTOVERTER® is noted on the converter nameplate (approximately 4.5 amps per ...
Three-Phase Power Quality Analyzer PowerPad™ Model 3945
... Record – Set up and record trend data at selectable rates from one sample/second to one sample every 15 minutes on as many as 22 different variables for all phases. See the recorded data on screen, zoom in and out and scroll the time axis to analyze the data. Power & Energy – Display Watts, VARs and ...
... Record – Set up and record trend data at selectable rates from one sample/second to one sample every 15 minutes on as many as 22 different variables for all phases. See the recorded data on screen, zoom in and out and scroll the time axis to analyze the data. Power & Energy – Display Watts, VARs and ...
Ladda PDF Lärdomsprov som heltext
... power plants. For the engine mechanical power increase there is already a proper design. The electrical side has not been studied in this scale. This thesis studies the following electrical components of the studied power plants: generator, cables, medium voltage switchgear and transformer. Some of ...
... power plants. For the engine mechanical power increase there is already a proper design. The electrical side has not been studied in this scale. This thesis studies the following electrical components of the studied power plants: generator, cables, medium voltage switchgear and transformer. Some of ...
MOSFET Switching Loss Model and Optimal Design
... overall efficiency of the buck converter. Since the model focuses on the performance of the CSD during turn-on and turnoff transitions of control FET, the parasitic inductances such as common source inductance and switching loop inductance for control FET that affect the switching transition have be ...
... overall efficiency of the buck converter. Since the model focuses on the performance of the CSD during turn-on and turnoff transitions of control FET, the parasitic inductances such as common source inductance and switching loop inductance for control FET that affect the switching transition have be ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.