Linear Actuator Controls
... Some versions of the DCG actuator control series can operate two actuators in parallel synchronous motion. To be able to use this feature the actuators must be equipped with feedback encoders. This function is useful when it is necessary to move two actuators to the same position with the same speed ...
... Some versions of the DCG actuator control series can operate two actuators in parallel synchronous motion. To be able to use this feature the actuators must be equipped with feedback encoders. This function is useful when it is necessary to move two actuators to the same position with the same speed ...
BD14000EFV-C Datasheet
... *1 This value is for ROHM standard board (1 layer 70x70x1.6mm) mounting. For temperatures above 25°C, use a 12.4mW/°C derating factor. Caution: Operating the IC over the absolute maximum ratings may damage the IC. The damage can either be a short circuit between pins or an open circuit between pins ...
... *1 This value is for ROHM standard board (1 layer 70x70x1.6mm) mounting. For temperatures above 25°C, use a 12.4mW/°C derating factor. Caution: Operating the IC over the absolute maximum ratings may damage the IC. The damage can either be a short circuit between pins or an open circuit between pins ...
VI-HAM™, VE-HAM
... asserted (active low) when the output bus voltage is within normal operating range (>270 Vdc) and 20 – 25 ms after DC-DC converters are enabled by the E/O signal of the HAM. This provides sufficient time for the converters to turn on and their output(s) to stabilize prior to P/OK being asserted, (Fi ...
... asserted (active low) when the output bus voltage is within normal operating range (>270 Vdc) and 20 – 25 ms after DC-DC converters are enabled by the E/O signal of the HAM. This provides sufficient time for the converters to turn on and their output(s) to stabilize prior to P/OK being asserted, (Fi ...
Status Indication Reference Design With LED
... input range from 4 to 40 V, the device is suitable for various applications from industrial to automotive for power conditioning from unregulated sources. The regulator’s quiescent current is 40-µA in sleep mode, which suits battery powered systems. An ultra-low 1-µA current in shutdown mode can fur ...
... input range from 4 to 40 V, the device is suitable for various applications from industrial to automotive for power conditioning from unregulated sources. The regulator’s quiescent current is 40-µA in sleep mode, which suits battery powered systems. An ultra-low 1-µA current in shutdown mode can fur ...
How to Use a Multimeter
... When a system is not working, continuity is one more thing to help troubleshoot the system. Here are the steps to take: 1. If the system is on, carefully check VCC and GND with the voltage setting to make sure the voltage is the correct level. If the 5V system is running at 4.2V check your regulato ...
... When a system is not working, continuity is one more thing to help troubleshoot the system. Here are the steps to take: 1. If the system is on, carefully check VCC and GND with the voltage setting to make sure the voltage is the correct level. If the 5V system is running at 4.2V check your regulato ...
10.1063-1.2234818
... We have demonstrated different generations of optoelectronic switches based on diffusive conduction.22,24,25 Among these, in this paper, we focus on the surface-normal architecture of a vertical dual-diode switch structure shown in Fig. 1共a兲, with the top diode serving as the photodetector and the b ...
... We have demonstrated different generations of optoelectronic switches based on diffusive conduction.22,24,25 Among these, in this paper, we focus on the surface-normal architecture of a vertical dual-diode switch structure shown in Fig. 1共a兲, with the top diode serving as the photodetector and the b ...
TPS2010A 数据资料 dataSheet 下载
... The TPS201xA family of power distribution switches is intended for applications where heavy capacitive loads and short circuits are likely to be encountered. These devices are 50-mΩ N-channel MOSFET high-side power switches. The switch is controlled by a logic enable compatible with 5-V logic and 3- ...
... The TPS201xA family of power distribution switches is intended for applications where heavy capacitive loads and short circuits are likely to be encountered. These devices are 50-mΩ N-channel MOSFET high-side power switches. The switch is controlled by a logic enable compatible with 5-V logic and 3- ...
Datasheet - IXYS Power
... The IXIDM1401_O driver module combines supreme compactness with the highest performance and reliability. It comprises a dual-channel driver core that targets medium power dual-channel IGBTs for up to 4 kV and applications such as inverters, drives & automation, UPS, renewable energy, transportation, ...
... The IXIDM1401_O driver module combines supreme compactness with the highest performance and reliability. It comprises a dual-channel driver core that targets medium power dual-channel IGBTs for up to 4 kV and applications such as inverters, drives & automation, UPS, renewable energy, transportation, ...
NX5P1000 1. General description Logic controlled high-side power switch
... The overall Rth(j-a) can vary depending on the board layout. To minimize the effective Rth(j-a), all pins must have a solid connection to larger Cu layer areas e.g. to the power and ground layer. In multi-layer PCB applications, the second layer should be used to create a large heat spreader area ri ...
... The overall Rth(j-a) can vary depending on the board layout. To minimize the effective Rth(j-a), all pins must have a solid connection to larger Cu layer areas e.g. to the power and ground layer. In multi-layer PCB applications, the second layer should be used to create a large heat spreader area ri ...
Sepam 1000 - Schneider Electric Belgique
... Phase and residual voltage transformers (VTs) are connected to the CCA 606 6-point connector on the ET module. Sepam 1000 can function with 1, 2 or 3 VTs. Residual voltage can be measured by two methods: c calculated by Sepam 1000 based on the phase voltages, c wired directly to Sepam 1000 from a tr ...
... Phase and residual voltage transformers (VTs) are connected to the CCA 606 6-point connector on the ET module. Sepam 1000 can function with 1, 2 or 3 VTs. Residual voltage can be measured by two methods: c calculated by Sepam 1000 based on the phase voltages, c wired directly to Sepam 1000 from a tr ...
BD6385EFV-LB
... An excess in the absolute maximum ratings, such as supply voltage, temperature range of operating conditions, etc., can break down the devices, thus making impossible to identify breaking mode, such as a short circuit or an open circuit. If any over rated values will expect to exceed the absolute ma ...
... An excess in the absolute maximum ratings, such as supply voltage, temperature range of operating conditions, etc., can break down the devices, thus making impossible to identify breaking mode, such as a short circuit or an open circuit. If any over rated values will expect to exceed the absolute ma ...
AC GENERATOR COMPONENTS
... Slip rings are electrical connections that are used to transfer power to and from the rotor of an AC generator (refer to Figure 1). The slip ring consists of a circular conducting material that is connected to the rotor windings and insulated from the shaft. Brushes ride on the slip ring as the roto ...
... Slip rings are electrical connections that are used to transfer power to and from the rotor of an AC generator (refer to Figure 1). The slip ring consists of a circular conducting material that is connected to the rotor windings and insulated from the shaft. Brushes ride on the slip ring as the roto ...
Table of Contents 8.0
... Onsite DC power system nominal load values are specified in U.S. EPR FSAR Tables 8.3-12 through 8.3-15. {Additional site-specific loads powered from the Class 1E battery source include an additional feeder breaker on the 31/2/3/4BDD bus that provides electrical power to the Essential Service Water E ...
... Onsite DC power system nominal load values are specified in U.S. EPR FSAR Tables 8.3-12 through 8.3-15. {Additional site-specific loads powered from the Class 1E battery source include an additional feeder breaker on the 31/2/3/4BDD bus that provides electrical power to the Essential Service Water E ...
MAX1652–MAX1655 High-Efficiency, PWM, Step-Down DC-DC Controllers in 16-Pin QSOP General Description
... and deliver up to 10A using a unique Idle Mode™ synchronous-rectified PWM control scheme. These devices automatically switch between PWM operation at heavy loads and pulse-frequency-modulated (PFM) operation at light loads to optimize efficiency over the entire output current range. The MAX1653/MAX1 ...
... and deliver up to 10A using a unique Idle Mode™ synchronous-rectified PWM control scheme. These devices automatically switch between PWM operation at heavy loads and pulse-frequency-modulated (PFM) operation at light loads to optimize efficiency over the entire output current range. The MAX1653/MAX1 ...
AC/DC and DC/AC Multilevel... Regulation. Applied To the Asynchronous Machine
... Tensions UC1 and UC2 illustrated in Figure 7.a. are very close and the voltage difference (UC1 - UC2) oscillates around a value small compared to that of UC1 and UC2. This difference is most important capabilities of low value, causing the instability of the input voltage to the inverter, and which ...
... Tensions UC1 and UC2 illustrated in Figure 7.a. are very close and the voltage difference (UC1 - UC2) oscillates around a value small compared to that of UC1 and UC2. This difference is most important capabilities of low value, causing the instability of the input voltage to the inverter, and which ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.