ECE 469 Power Electronics Lab Manual
... electric power equipment, electromagnetic design, radiation, semiconductor physics and processing, analog and digital circuit design, control systems, and a tremendous range of sub-areas. Major applications addressed by power electronics include: ·Energy conversion for solar, wind, fuel cell, and ot ...
... electric power equipment, electromagnetic design, radiation, semiconductor physics and processing, analog and digital circuit design, control systems, and a tremendous range of sub-areas. Major applications addressed by power electronics include: ·Energy conversion for solar, wind, fuel cell, and ot ...
36V H-Bridge Transformer Driver for Isolated Supplies General Description Benefits and Features
... defines the output voltage, allowing selection of virtually any isolated output voltage. The device features adjustable current limiting, allowing indirect limiting of secondary-side load currents. The current limit of the MAX13256 is set by an external resistor. A FAULT output asserts when the devi ...
... defines the output voltage, allowing selection of virtually any isolated output voltage. The device features adjustable current limiting, allowing indirect limiting of secondary-side load currents. The current limit of the MAX13256 is set by an external resistor. A FAULT output asserts when the devi ...
INTRINSICALLY SAFE ANALOGUE ADDRESSABLE SMOKE
... The standard XP95 communications protocol is designed to be very robust and to give the maximum flexibility to designers of loop driver circuits. The current and voltage levels used are chosen to be well above noise levels and to operate in adverse conditions with the minimum of errors. The maximum ...
... The standard XP95 communications protocol is designed to be very robust and to give the maximum flexibility to designers of loop driver circuits. The current and voltage levels used are chosen to be well above noise levels and to operate in adverse conditions with the minimum of errors. The maximum ...
S225-20-1
... ratings only. "Boost" units are applied primarily to raise voltage on unregulated circuits or on that part of a regulated circuit which is beyond the range of bus regulation. "Buck" units can be used to lower voltage on branch circuits near a substation. Voltage on the balance of the circuit is sign ...
... ratings only. "Boost" units are applied primarily to raise voltage on unregulated circuits or on that part of a regulated circuit which is beyond the range of bus regulation. "Buck" units can be used to lower voltage on branch circuits near a substation. Voltage on the balance of the circuit is sign ...
PDF
... 1. An offline scheme for mapping the initial set of applications and computing the appropriate voltage/frequency to minimize power and energy consumption while meeting all deadlines (Sec. 4). 2. An online scheme for dynamically mapping applications arriving at run-time and re-evaluating the voltage/ ...
... 1. An offline scheme for mapping the initial set of applications and computing the appropriate voltage/frequency to minimize power and energy consumption while meeting all deadlines (Sec. 4). 2. An online scheme for dynamically mapping applications arriving at run-time and re-evaluating the voltage/ ...
shortwave power amplifier with gu84b
... allowed. The amplifier must not be installed in a constrained surrounding (i.e. tight shelves etc.) ...
... allowed. The amplifier must not be installed in a constrained surrounding (i.e. tight shelves etc.) ...
BD63710AEFV
... ○VCC1,VCC2/Power supply terminal Motor’s drive current is flowing in it, so please wire in such a way that the wire is thick & short and has low impedance. Voltage VCC may have great fluctuation, so please arrange the bypass capacitor of about 100μ~470μF as close to the terminal as possible and adju ...
... ○VCC1,VCC2/Power supply terminal Motor’s drive current is flowing in it, so please wire in such a way that the wire is thick & short and has low impedance. Voltage VCC may have great fluctuation, so please arrange the bypass capacitor of about 100μ~470μF as close to the terminal as possible and adju ...
What do resistors do?
... digit 7. The third band is called the MULTIPLIER and is not interpreted in quite the same way. The multiplier tells you how many noughts you should write after the digits you already have. A red band tells you to add 2 noughts. The value of this resistor is therefore 4 7 0 0 ohms, that is, 4 700 , o ...
... digit 7. The third band is called the MULTIPLIER and is not interpreted in quite the same way. The multiplier tells you how many noughts you should write after the digits you already have. A red band tells you to add 2 noughts. The value of this resistor is therefore 4 7 0 0 ohms, that is, 4 700 , o ...
S701 Soft Start Controllers and TL Torque Limiters for Intelligent
... Controllers and TL Torque Limiters provide solid-state reduced voltage control of three-phase and single-phase motors. These easy-to-install, compact devices are rated up to 25A, providing controlled acceleration and deceleration of fractional to 15HP/11kW motors at 480/400V AC. Torque control, soft ...
... Controllers and TL Torque Limiters provide solid-state reduced voltage control of three-phase and single-phase motors. These easy-to-install, compact devices are rated up to 25A, providing controlled acceleration and deceleration of fractional to 15HP/11kW motors at 480/400V AC. Torque control, soft ...
LP3871/LP3874 0.8-A Fast Ultra-Low Dropout Linear Regulators
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
Design, Construction and Characterization of a Line-Type
... impedance level and 11.4 nF of capacitance PFN was simulated and then assembled to supply 9 kV and 0.7 Ps voltage pulses in a pulse transformer primary circuit, at a pulse recurrence frequency (PRF) of 2 kHz. The pulse transformer was designed to impedance matching and d-c isolation between the PFN ...
... impedance level and 11.4 nF of capacitance PFN was simulated and then assembled to supply 9 kV and 0.7 Ps voltage pulses in a pulse transformer primary circuit, at a pulse recurrence frequency (PRF) of 2 kHz. The pulse transformer was designed to impedance matching and d-c isolation between the PFN ...
MAX1946 Single USB Switch with Autoreset and Fault Blanking in Tiny TDFN
... The MAX1946 provides several safety features to protect the USB port. Built-in thermal-overload protection turns off the switch when the die temperature exceeds +160°C. Accurate internal current-limiting circuitry protects the input supply against both overload and shortcircuit conditions. An open-d ...
... The MAX1946 provides several safety features to protect the USB port. Built-in thermal-overload protection turns off the switch when the die temperature exceeds +160°C. Accurate internal current-limiting circuitry protects the input supply against both overload and shortcircuit conditions. An open-d ...
IF 1720 Revision 2
... screws. All components in the fixture are prewired so only line in, neutral, and ground need to be connected in the fixture to the terminals per the wiring diagrams using methods that comply with all applicable codes. Use 75°C min and 600 V min supply cord with outer sheath diameter in accordance wi ...
... screws. All components in the fixture are prewired so only line in, neutral, and ground need to be connected in the fixture to the terminals per the wiring diagrams using methods that comply with all applicable codes. Use 75°C min and 600 V min supply cord with outer sheath diameter in accordance wi ...
A v
... – Kilby conceived the monolithic idea – Building entire circuit out of Germanium or Silicon – Phase-Shift Oscillator, Multivibrator were build from Germanium with thermally bonded gold connecting wires. – Noyce manufactured multiple devices on a single piece of Silicon and was able to reduced the si ...
... – Kilby conceived the monolithic idea – Building entire circuit out of Germanium or Silicon – Phase-Shift Oscillator, Multivibrator were build from Germanium with thermally bonded gold connecting wires. – Noyce manufactured multiple devices on a single piece of Silicon and was able to reduced the si ...
ADD8754-EVAL Evaluation Kit for LCD Power
... Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Analog Devices reserves the right to change devices or specifications at any time ...
... Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Analog Devices reserves the right to change devices or specifications at any time ...
Chapter 3
... • Electrons flow – Create lines of magnetic force that circle around the path of flow called magnetic flux lines • These lines space themselves evenly along a current-carrying wire ...
... • Electrons flow – Create lines of magnetic force that circle around the path of flow called magnetic flux lines • These lines space themselves evenly along a current-carrying wire ...
MAX9171/MAX9172 Single/Dual LVDS Line Receivers with “In-Path” Fail-Safe General Description
... ESD protection structures are incorporated on all pins to protect against electrostatic discharges encountered during handling and assembly. The receiver inputs of the MAX9171/MAX9172 have extra protection against static electricity. These pins are protected to ±13kV without damage. The structures w ...
... ESD protection structures are incorporated on all pins to protect against electrostatic discharges encountered during handling and assembly. The receiver inputs of the MAX9171/MAX9172 have extra protection against static electricity. These pins are protected to ±13kV without damage. The structures w ...
MAX9633 Dual 36V Op Amp for 18-Bit SAR ADC Front-End EVALUATION KIT AVAILABLE
... Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Expo ...
... Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Expo ...
Virus Zapper - Everyday Practical Electronics
... another circuit which could easily be put together from parts many readers will already have. However, these basic circuits are tedious to use because they involve clock-watching to time both the treatments and the intervals, or operation of a timer of some kind which is awkward when one is holding ...
... another circuit which could easily be put together from parts many readers will already have. However, these basic circuits are tedious to use because they involve clock-watching to time both the treatments and the intervals, or operation of a timer of some kind which is awkward when one is holding ...
SN65LBC182 数据资料 dataSheet 下载
... accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and ...
... accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and ...
MAX1759 Buck/Boost Regulating Charge Pump in µMAX General Description
... allows the input voltage to be higher or lower than the regulated output voltage. Internal circuitry senses VIN and V OUT and determines whether V IN must be stepped up or stepped down to produce the regulated output. When VIN is lower than VOUT, the charge pump operates as a regulated step-up volta ...
... allows the input voltage to be higher or lower than the regulated output voltage. Internal circuitry senses VIN and V OUT and determines whether V IN must be stepped up or stepped down to produce the regulated output. When VIN is lower than VOUT, the charge pump operates as a regulated step-up volta ...
DVR5V0W Features Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.